B6K2 Standalone Access Controller User Manual V1.0
NetDigital Security http://www.netdigital.com.au
2
Content
1 Overview ......................................................................................................................................................................4
1.1 Introduction...........................................................................................................................................................4
1.2 Function features.................................................................................................................................................4
1.3 Functional unit......................................................................................................................................................4
1.4 Technical parameters..........................................................................................................................................5
1.5 Applicable models ...............................................................................................................................................5
2 Installation, wiring and debugging............................................................................................................................5
2.1 Installation ............................................................................................................................................................5
2.2 Wiring ....................................................................................................................................................................6
2.3 Debugging ..........................................................................................................................................................13
3 Getting Started ..........................................................................................................................................................13
3.1 Enter management menu operation mode....................................................................................................14
3.2 Change admin password..................................................................................................................................14
3.3 Set controller to Single-door mode .................................................................................................................14
3.4 Set door opening time to 2S ............................................................................................................................14
3.5 Add User Card ...................................................................................................................................................14
3.6 Add User PIN .....................................................................................................................................................14
3.7 Exit Management menu operation mode.......................................................................................................15
3.8 User open door ..................................................................................................................................................15
4.Basic Functions.........................................................................................................................................................15
4.1 Management menu operations........................................................................................................................15
4.1.1 Change Admin Password..........................................................................................................................15
4.1.2 Set or delete Super-open-password .......................................................................................................16
4.1.3 Set admin card ...........................................................................................................................................16
4.1.4 Delete admin card......................................................................................................................................16
4.1.5 Set Machine Mode.....................................................................................................................................16
4.1.6 Limits types of reading card......................................................................................................................17
4.1.7 Restore to default settings........................................................................................................................17
4.1.8 Add User......................................................................................................................................................17
4.1.9 Delete user..................................................................................................................................................18
4.1.10 Set open door methods...........................................................................................................................18
4.1.11 Set Multi-card to open door ....................................................................................................................18
4.1.12 Set lock working mode............................................................................................................................19
4.1.13 Set Limits User Mode..............................................................................................................................19
4.1.14 Set Open-time ..........................................................................................................................................19
4.1.15 Set notification to close door..................................................................................................................19
4.1.16 Set Alarm-time..........................................................................................................................................19
4.1.17 Set Anti-dismantle alarm function..........................................................................................................20
4.1.18 Set alarm or doorbell output function....................................................................................................20
4.1.19 Set Anti-crack function ............................................................................................................................20
4.1.20 Set LED indicator light mode..................................................................................................................20
4.1.21 Adjust the brightness of the normally bright red indicator..................................................................20

B6K2 Standalone Access Controller User Manual V1.0
NetDigital Security http://www.netdigital.com.au
3
4.1.22 Set key backlit mode ...............................................................................................................................21
4.1.23 Adjust brightness of key backlit..............................................................................................................21
4.1.24 Set buzzer mode......................................................................................................................................21
4.1.25 Adjust key volume....................................................................................................................................21
4.1.26 Set the # key whether it can be used doorbell key.............................................................................21
4.1.27 Set doorbell key mode ............................................................................................................................22
4.2.28 Set reader output format......................................................................................................................22
4.2 Admin card or PIN operation ...........................................................................................................................23
4.2.1 Set-card operation .....................................................................................................................................24
4.2.2 Add-card operation.....................................................................................................................................24
4.2.3 Delete-card operation................................................................................................................................24
4.2.4 Super-open-card operation.......................................................................................................................24
4.2.5 Super-open-password operation .............................................................................................................24
4.2.6 Anti-duress-card operation........................................................................................................................24
4.2.7 Authorization-card operation ....................................................................................................................25
4.2.8 Normal-open-card operation.....................................................................................................................25
4.3 Users operation...............................................................................................................................................25
4.3.1 Get user card or PIN..................................................................................................................................25
4.3.2 Change user PIN........................................................................................................................................25
4.3.3 User Open door..........................................................................................................................................25
4.4 Other operations................................................................................................................................................26
4.4.1 Cancel alarming .........................................................................................................................................26
4.4.2 Admin Password initialization...................................................................................................................26
4.4.3 Restore factory settings ............................................................................................................................26
4.5 Operation characteristics in different machine modes.................................................................................26
4.5.1 Operation characteristics in reader mode ..............................................................................................26
4.5.2 Operation characteristics in Single-door mode......................................................................................27
4.5.3 Operation characteristics in Double-doors mode..................................................................................27
4.5.4 Operation characteristics in Interlock mode...........................................................................................27
4.5.5 Operation characteristics in Demo mode ...............................................................................................27
5 Management menu summary table .......................................................................................................................27
5.1 Reader mode management menu summary table.......................................................................................27
5.2 Single-door mode management menu summary table................................................................................29
5.3 Double-doors mode management menu summary table............................................................................32
5.4 Interlock mode management menu summary table.....................................................................................33
5.5 Demo mode management menu summary table .........................................................................................34
6 Precautions in use ....................................................................................................................................................34
7 Common troubleshooting ........................................................................................................................................35

B6K2 Standalone Access Controller User Manual V1.0
NetDigital Security http://www.netdigital.com.au
4
1 Overview
1.1 Introduction
This series of products are using the new 32-bit microcontroller ARM core design with powerful functions. They are very
stable and reliable. It’s a new generation of multi-function access controller, includes Reader mode, Single-door mode,
Double-doors mode, Interlock mode, Demo mode etc. They can be widely used in office buildings, homes, schools,
condominium, apartments, flats, banks, gates and other places.
1.2 Function features
➢Option for 125 KHz’s EM& HID card.
➢Option for 13.56MHz’s IC&CPU card.
➢Optional for metal backlit keypad or infrared keypad.
➢Option for single-door or double-door.
➢Single-door controller can be set to Reader mode, Interlock mode and demo mode.
➢Specific reader mode that customer can set output format.
➢Support Card and PIN, Multi-cards to open the door.
➢Support Super-open-card and Super-open-password to open door.
➢Support Add-card, Delete-card, Anti-duress-card, Authorization-card, and Normal-open card operation.
➢Support admin password card operation, for quick access to the management menu.
➢The user card capacity up to 20,000, the admin card capacity up to 21.
➢Support Set-card operation, for quick access to the management menu.
➢The “#” key can be used as doorbell button.
➢In Reader mode, the red and green LED indicator can be controlled externally.
➢Self-adaption infrared Anti-demolition detection technology. Controller can alarm 24/7 and it will not be affected by visible
light interference.
➢Unlocking signal output by NO, NC, COM relay.
➢Alarm and doorbell signal output by MOS and it can be the driver of the alarm or the doorbell.
1.3 Functional unit
B6K-EH Plus,B6K-IC Plus,
B6K2-EH Plus,B6K2-IC Plus
Backlit key
Logo
Antenna
Metal case
Indicator light

B6K2 Standalone Access Controller User Manual V1.0
NetDigital Security http://www.netdigital.com.au
5
1.4 Technical parameters
➢Working Voltage: AC/DC10-28V
➢Standby current: ≤35mA(Input DC12V)
➢Operating current: ≤100mA(Input DC12V)
➢Working temperature: -40~60℃
➢Working humidity: 0~95%
➢Lock signal relay contact current: ≤1A
➢Alarm (or doorbell) signal MOS tube output current: ≤1A
➢Distance of reading EM card:≤5cm
➢Distance of reading HID card:≤5cm
➢Distance of reading IC card:≤5cm
1.5 Applicable models
This user manual applies to the following models:
Thumbnails
Product name
Product model
Card type
Keypad
Lead wire
Single-door Standalone Access
Controller
B6K-EH Plus
EM/HID
Own
12
B6K-IC Plus
IC/CPU
Own
12
Double-doors Standalone Access
Controller
B6K2-EH Plus
EM/HID
Own
16
B6K2-IC Plus
IC/CPU
Own
16
2 Installation, wiring and debugging
2.1 Installation
With the special anti-demolition screw-driver remove the anti-demolition screw at the bottom of the device. Take off the bottom
case, and contrast the opening position of the bottom case and use the impact drilling to open the corresponding hole on the
wall. It includes an outlet hole with a diameter greater than 8mm and four plastic screw holes with a diameter of 6mm. Then
insert four matching plastic expansion screws, fix the bottom case on the wall with four matching self-tapping screws.

B6K2 Standalone Access Controller User Manual V1.0
NetDigital Security http://www.netdigital.com.au
6
2.2 Wiring
According to the selected wiring diagram, cut the lead wire to the right length and cut off the excess thread, through the wall
or in the embedded box, connect the system line with the wiring diagram. Be careful not to connect the wrong or short circuit,
otherwise it may burn the machine. After checking, power on for a short time, test if the indicator light is normal and if the
buzzer ring one time beep. Otherwise, power off immediately and recheck the wiring properly. After check again and if all is
well, install the front case of the product onto the bottom case on the wall and fix it with the anti-demolition screw as below:
The product wiring colors and functions are shown in the following table:
Color
Symbol
Functions
Light green
AC2
One port of the AC power supply
Blue
NO
Normal open port of Relay
Purple
COM
Common port of Relay
Orange
NC
Normal close port of Relay
Grey
ALARM(BELL)
Alarm (or doorbell) signal MOS drain output
Yellow
OPEN(BEEP)
Exit button input(or external control input of buzzer)
Brown
D_IN(LED_G)
Door contact input (or external control input of green LED)
Red
+12V(AC1)
Positive DC power(or another port of AC power supply)
Black
GND
Ground
Green
D0
Wiegand signal, D0 input or output(or RS232-TTL signal output: Tx)
White
D1
Wiegand signal, D1 input or output(or RS232-TTL signal input : Rx)
Pink
D_IN2(LED_R)
Door contact input of zone 2 (or external control input of red LED)
Yellow & Black
OPEN2
Exit button input of zone 2
White & Black
NO2
Normal open port of Relay 2
Green & Black
COM2
Common port of Relay 2
Red & Black
NC2
Normal close port of Relay 2