Maximum battery charging current: 0,35A
Module disconnect battery when it’s
voltage less than: 9,5V
Black
Red
12V battery
7Ah/20HR
3.15A
COM
+BELL
20VAC COM -PGM+BELL
System start-up with no 230V AC power
Connect 12V battery with P
seriescontrol panel by using
a BAT connector. Use the
jumper to close the shown
pins for 1 second.The
system will start operating;
howeverAC loss trouble will
beindicated.
Jumper
Keypad mounting
Keypad
Use only self-tapping screws with flat
(countersunk) head (3x30 PH) to mount keypad’s
plasticonthewall.Makesurethescrewisscrewed
completely and screw head hides in the plastic.
Other shape screws or not completely screwed
screws may touch keypad electronics and cause
damageof keypad.
Wiring manual
Intruder alarm system
Maximum current out of +AUX:
Maximum battery charging current:
1,5 A
2A
+1 A
+0,35 A
Maximum load ratings and electrical characteristics
of P series control panels
Maximum current out of +BELL:
Maximum current out of +PGM for P16:
Maximum current out of +PGM for P32, P64:
+2,0 A
+0,5 A
+0,9 A
Control panel disconnect battery when it’s voltage less than: 9,5 V
Minimum AC voltage on 20 VAC:
Note: with ~16 V on 20 VAC max DC current generated by
control panel power supply is 0,7A.
Maximum current of fast blowing fuse used in battery circuit:
~16 V
3,15 A
Maximum AC voltage on :
Note: higher than V voltage can damage control panel
20 VAC
~22 .
Maximum voltage on +AUX, +BELL, +PGM outputs:
Minimum voltage on +AUX, +BELL, +PGM outputs:
~22 V
+13,9 V
+12,0 V
Maximum current of slow blowing fuse used in primaryAC:
Maximum AC power consumption:250 mA
150 mA
Maximum long term output current of P16 control panel:
(I + I + I + I 1,5 A )
+AUX +BELL +PGM BAT. CHARGE
Maximum long term output current of P32, P64 control panel:
(I + I + I + I 2 A )
+AUX +BELL +PGM BAT. CHARGE NowservicePINisrestoredto0000valueandsystemwithenabledservice
mode.ToresetuserPINfollowthesteps:
donotblockservice bypressingENT;
pressarrowkeytonavigateinmenu;
go to: Main Menu/Settings/Users/Edit Users/ enter 0000 /Reset PIN to
default/YES
Restoring service PIN to default value
Electrical characteristics and additional information
Live
wire
L
Neutral
wire
N
Protective
Earth wire
PE Wire
Main Protective
Earthing terminal
COM
+BELL
DAT
+AUX
Z1
COM
Z2
CLK
COM
-PGM
+PGM
Maximum current into -PGM: -0,3A
Torestoredefaultvalue(0000)forservicePIN,followthesteps:
disconnectcontrolpanelfrom20VACpowersupply;
disconnectcontrolpanelfromback-upbattery;
makeshortcircuitof -PGM and zone Z1;
connectcontrolpanelto20VACpowersupply.
Calculated life expectancy for P series control panels at 40
ambient temperature: °C
-20°C to +55°COperating temperature range: 12 years
Note: ambient temperature over 40 may reduce life expectancy.°C
Note: poor ventilation of cabinet increase ambient temperature.
Page 3
Control Panels P16, P32, P64
20 VAC
20VAC COM -PGM +PGM COM CLK DAT +AUX Z1 COM Z2+BELL
Fuse
250mA
20 VAC
Maximum long term current out of PWR20:
Maximum current out of +AUX:
2,0A
+1A
Maximum load ratings and electrical
characteristics of PWR20
Maximum current out of +BELL:
Maximum current into -PGM1:+2A
-0,05A
Wiring of modules in large or high security level system
12V battery
7Ah/20HR
Black
Red
Safe wiring of outdoor siren
Use other (than control panel) transformer and
rechargeable 12V 7Ah battery to power up
PWR20.Incase alarmsystem includes PWR20 it
is recommended to wire an outdoor siren to the
PWR20terminals+BELL,-PGM1, (-PGM2), COM
same as shown on page 2. Failure of siren’s
internal battery or the siren itself will not affect
PWR20 – power supply module with bus
repeater
Repetition of system bus is a perfect solution
when some system modules (PROX8, EXTx16)
are placed outside premises or in area not
protected by detectors. It is recommended to wire
to repeated (by PWR20) bus all outside proximity
readers or keypads located near to entry door.
Attempt to make a short circuit on outside module
will make no affect to system performance as
PWR20will detect theshortcircuitonrepeatedbus
and will disconnect repeated bus from main bus.
Terminals CLK-I, DAT-I are inputs for main bus,
terminals CLK-O and DAT-O are outputs of
repeatedbus. For powersupply modules mustuse
PWR20output +AUX.
Live
wire
L
Neutral
wire
N
Protective
Earth wire
PE
Power supply
distribution board
Main Protective
Earthing terminal
Module address LED
Low battery indicator
Battery charging on
Overload of +BELL or + AUX.
X1
BAT
OVL
CHG
LOW
MOD
PWR20
3.15A
Fuse
250mA
AC power transformer:
Primary winding: 230V AC 50Hz
Secondary winding: 20V AC 50Hz
~~DAT-O
CLK-O
COM
+12V
+12VCLK COMDAT
COM
DAT
+12V
CLK
DAT from Pxx
CLK from Pxx
COM from Pxx
+BELL
COM
-PGM1
TMP
COM
+AUX
CLK-I
CLK-O
DAT-I
DAT-O
20 VAC
DAT-O
CLK-O
COM
+12V
+12VCLK COMDAT
COM
DAT
+12V
CLK
+BELL
~20VAC COM-PGM1TMP COM +AUXCLK-ICLK-O
DAT-IDAT-O
Module
(I + I + I 2 A )
+AUX +BELL BAT. CHARGE