TABLE OF CONTENTS
General Warnings About User Manual 1
Safety Instructions 2
Application Areas 3
Shipping Water Pumps 4
Transportation 4
Storage 5
Installation 6
Electrical Connections 12
First Operation 14
Lubrication 16
Dismounting of Pumps and Repair 17
Cross Section Drawings 19
Spare Parts 20
Failures and Troubleshooting 20
Tightening Moments 23
Noise Level 24
List Indicating Service Stations 25

GENERAL WARNINGS ABOUT USER MANUAL
Aim of this user manual is; ,
- to convey instructions about installation, maintenance and repair of pump, and to
explain start, operation and stop methods of pump.
-. Absolutely keep this manual in a secured place to be accessed easily
by official who is responsible for safe operation and maintenance of pump.
- Pump should not be operated under conditions which are not mentioned in
purchase order. Because, operational conditions which are given in purchase order
are considered at material selection and trial.
SEMPOMP , does not accept any warranty conditions for all kind of changes and
repair operations which are performed by user and unauthorized people.
- Instructions in this manual should carefully be examined and applied in every
installation and operation process of pump for preventing misuse.
- Responsible Personnel should be experienced and have knowledge about related
standards.
- If it is necessary to operate pump under conditions out of the ones those are
mentioned in purchase order, please contact with SEMPOMP authorized service.
SEMPOMP shall not be liable for damages which may occur because of operation
under conditions out of mentioned ones without written permission of service.
- If carried pumps shall not be installed immediately, it should be kept in an
environment where temperature and humidity does not change so frequently. If
appropriate precautions are not taken, very high temperatures and low temperatures
and humidity may severely damage pump.
- User is responsible for control and installation to be performed by authorized
personnel who have read and examined this user manual.
This user manual does not cover safety rules to be applied in usage area.
Usage tine for pumps which is determined and announced by Ministry is 5(five)
years.
1

SAFETY INSTRUCTIONS
- You should absolutely obey the following safety instructions.
- Never touch the pump and pipes having temperature more than 80 ºC. Necessary
precautions should be taken for warning users. (E.g Warning signs and signboards )
- Never operate pump in reverse direction.
- Do not walk over pump pr pipes which are connected to pump.
- Any operation which will be done in pump should be performed by at least two
staffs.
- No works should certainly be done over without stopping pump group.
- Power coming to pumps should be off and you should be sure that it will not operate
again before you make any work
- Absolutely install the safety guards which were dismounted before after work in
pump has finished.
- Tensions and cricks in pipe system absolutely should not reach to pump.
- Do not make any operation while pump and pipes which are connected to pump are
under pressure.
- Cloths of personnel who will work over should be suitable and/or they should use
safety equipments.
-Never do any operations when pump is still hot.
- Electrical connection related with pump and auxiliary equipments should be suitable
with local rules and made by authorized personnel.
- Operate pump with only specified conditions.
- Do not insert your hand and fingers into holes and spaces over pump body.
- Be always careful while working with pumps discharging hazardous liquids.
2

ARS-D SERİES PUMPS
ARS Series Pumps are centrifugal pumps having horizontal shaft, separable radial
body, are multi staged, has closed impellor, diffuser
Usage Areas of Motor Water Pump
Pumps are suitable for discharging liquids which are low viscose, whose flow
temperature is up to 120ºC and which are clean or a little dirty. (Max20mg/dm³) . In
addition to others; main application areas are:
- Heating and Cooling Systems
- Water Supply
- Fire Extinguishing Plants
- Water Supply and Circulation Systems in Industrial Plants
- Watering Systems
- Power Stations
Explanation of Pump Codes
ARS-D 32 / 06
Pump Type
Vertical Shaft
Rated Diameter of Discharge Flange (DN-mm)
Number of Stages(piece)
Technical information
Speed : Up to 3600 d/d rpm
Discharge Flange :DN32 …DN200
Suction Flange :TS ISO 7500-2/PN16,DIN2533/PN16
Discharge Flanges :TS ISO 7500-2/PN40,DIN2535/PN40
Operational Temperature :-10ºC…140ºC cooled soft gasket
Ambient Temperature (Maximum) :+40ºC
Body Pressure :30 bar-(50 Bar)
Isolation Class :F
Protection Class :IP55
Motor Connection :3 Phase-380 V-50 Hz
Motor Options(Optional) : Special Voltage Special Frequency
3

SHIPPING of PUMPS
- Check whether all materials in delivery list are sent. .
- If there is damage during shipping please notify SEMPOMP Shipping Department
and Transportation company.
- If there are missing materials, immediately inform SEMPOMP Shipping Department.
-. Check whether packaging is damaged during transportation.
- Please carefully take out packaged pump and accessories (if any). Check whether
they are damaged during transportation.
CARRYING
General warnings.
Absolutely obey the following rules during transportation.
-.Use proper wooden crane, forklift, or hoisting mechanisms For unloading or
loading wooden cases, packages, boxes and palettes depending on their weight and
volume.
- Wear gloves, hard tip shoes and helmet during carrying works.
4

Pump and Motor Group Loading/Unloading
Before lifting pump group please determined the following properties.
- Locations of lifting points
- Total weight and centre of gravity.
-Packaging external dimensions
- During loading/unloading make accelerating and braking operations as it shall not
cause any damage for working personnel.
-Load lifting capacity should be suitable with pump and pump group weight.
- You should never stay under or near lifted load.
- Pump should be hoisted as it is indicated in Figure 1-1 and Figure 1-2 for not
causing any damage in pumps. Motor hanging ring should absolutely not be used
while lifting complete group.
- Load should be kept in lifted position more than required time.
- Pump and pump group should always be lifted and carried in horizontal position
Figure 1-1 Single Pump Figure 1-2 Motopomp
STORAGE
- If pump group is not immediately installed, it should be stored in a place which is
clean dry and does not include freezing and explosion risk.
- If pump bearing are type which should be greased, they should be extra greased for
preventing entry of moisture to bearings around shaft
- Pump should be protected from moisture, dust, dirt and foreign objects by covering
with suitable material. 5

- Pump shaft should be rotated a few turns (e.g once a week) for preventing pitting
around pump bearing surfaces and jamming of shaft.
INSTALLATION
Installation of pump to its place and connection setup should only be done by expert
personnel. Failed installation and pump ground may cause failures.
This situations are not covered with warranty
- If pump is supplied without motor (without motor, proper motor should be selected
prior start to installation of group.
Following properties should be considered during motor selection.
- Maximum power of pump (in all operation ranges)
- Operational revolution of pump shaft
- Necessary power supply
- Motor Type
- Motor connection type ( footed, flanged, horizontal, vertical etc. )
- If pump is purchased as single pump (without motor and chassis); a proper frame
should be constructing for putting this group over it. Frame to be constructed should
have dimensions and strength which will not permit vibration and shape defects.
Starting the motor should be done with control cabinet which is prepared according
to power of motor and floater should absolutely be used for preventing to operate
without water. Also collector diameter should be suitable with pumps efficient
operational ranges not with installation.
Before start to pump installation
- Protecting parts in discharge and suction pumps should be removed and cleaned
well.
-. Pump should be installed in a places which does not have freezing or explosion
risk and have well air conditioning.
- There should be enough space around pump for accessing pump easily and for
maintenance operations and there should be sufficient height and space for lifting
pump if necessary.
- Pump suction pipe should be as short as possible.
- You should be carefully work at pump installation ground preparation and
installation of pump group into its place. Incorrect and careless installation causes
early wearing of pump parts and failures.
6

- Pump ground should be so heavy to absorb vibrations and sturdy to prevent bends
and adjustments defects. Ground concrete should completely be solidified,
completed its plug time and proper stud bolts are placed in pump frame fixing holes
and proper fixing lugs should be placed for using in making connections with welding.
Concrete and plate upper surface should be horizontal and very smooth.
Installation
Installation of pump group to ground by anchoring stud bolts:
- Pump group is placed to center the stud bolt slots which are opened in ground
concrete.
- Anchoring stud bolts are inserted through fixing holes over pump frame fixing holes
and places into their slots.
- Pump group is places over base concrete. Water balance is placed over pump
discharge flange and horizontality of pump is controlled. If there is a horizontal
imbalance in pumps position, steel wedges are put under frame and balance of pump
group is obtained.
- Nuts of anchoring stud bolts are installed.
- Anchoring stud bolt holes are filled with concrete grout.
- Anchoring stud bolts are reciprocally tightened.
- Coupling setup is controlled in this situation.
- Concrete is poured into pump frame. Joining of poured concrete and ground
concrete is cared.
- Complete binding of concrete is controlled and anchoring stud bolts are reciprocally
tightened.
- Coupling adjustment is again controlled with template. If there is maladjustment,
coupling adjustment is made again.
- Discharge and suction flange fixings of pump are controlled again. If there are
unnecessary strains and cricks they are eliminated.
- Coupling guards are placed after coupling adjustment.
:Installation of pump group with concrete fixing plug :
- Pump is placed into ground concrete or the ground to be installed carefully.
7

Pump group frame fixing holes are marked to concrete. Pump group lifted again.
- Marked places where fixing plugs will be placed are drilled carefully according to
standards.
- Fixing plugs are carefully placed into drilled places.
- Steps for installation with anchoring stud bold are made here with same order.
Installation of Pipe Equipment
- Nominal diameter of pump discharge and suction pumps are not an indicator for
correct diameters for discharge and suction pipes. Pipes and accessories having
diameter less than pump opening diameter should absolutely not be used. Especially
bottom backwater valve, dirt retainer, filter and check valves and similar elements
should be chosen to having a larger passing area. Never use pump as a supporting
point for pipe installation or a as a carrier.
-Cricks and stresses in pipe and pipe weight equipments should be controlled
whether they effect pump. For this reason, bolts of discharge and suction flanges
should be loosen and it should be controlled whether pipe system exerts a stress
over pump.
- Never use pumps as a support point or carrier for a pipe installation
-Flow rates generally should not exceed 2m/s in suction pipe and 3 m/s discharge
pipe. High speeds cause decrease in pressure which will cause cavitations
conditions and excess friction losses in discharge pipe.
- Pipe system should be supported from points which are close to pipe
- Pipe connections should be made by flanges. Flanges gaskets should be produced
from suitable material and should have suitable dimensions. Gaskets which will be
used between flanges should be centered for not preventing water flow.
- Proper expansion equipments should be used for preventing additional forces to
pump which may occur because of expansion in systems which operate in over
vibrant and hot liquids.
8
Indice
Altri manuali Sempomp Pompa dell'acqua
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente