Seneca MyBoat Manuale utente

1
USER MANUAL MI004913-E
User Manual

USER MANUAL MI004913-E
ACTIVATION CODE

USER MANUAL MI004913-E
TABLE OF CONTENTS
1 - INTRODUCTION:
-Content of the pack p.2
-Logical diagram of the MyBoat system p.3
-Product description p.4
-MyBoat control unit p.5
-Monitoring sensors p.6
-Sensor representation in the Home screen p.7
2 - INSTALLATION
-Installation of the MyBoat control unit p.8
-Replacing the sensor battery p.9
-Sensor installation p.10
3 - ACTIVATION
-Cloud account registration and MyBoat service activation p.16
-Product activation p.17
4 - MYBOAT MOBILE APP
-HOME screen p.20
-STATUS screen p.21
-HISTORY screen p.22
-SETTINGS menu p.23
5 - ADVANCED SETTINGS
-Procedure to replace a sensor p.30
-AdvancedcongurationoftheMyBoatcontrolunit p.31

02
USER MANUAL MI004913-E
1 - INTRODUCTION: CONTENT OF THE PACK
1 - INTRODUCTION: LOGICAL DIAGRAM OF THE MYBOAT SYSTEM
1
2
3
1 - MyBoat control unit
5 - Power cable with cigarette lighter plug
2 - Sensors (the image refers to a kit with 8 sensors)
6 - Batteries for each sensor (included and already installed)
4 - SIM card (optional, see leaet)3 - User Manual
7 - Control unit xing support 8 - Self-tapping screws for wall xing (x2)
22
2 2 2
2
52

03
USER MANUAL MI004913-E
1 - INTRODUCTION: CONTENT OF THE PACK
1 - INTRODUCTION: LOGICAL DIAGRAM OF THE MYBOAT SYSTEM
S1 S2 S3 S4 S5 S6 S7 S8
DIN1 DIN2 DIN3 DIN4
From 2 to 8 sensors (*)
Digital inputs
Relay digital outputs
Power supply
AUX 1 AIN 2
AUX 2
Analogue inputs
4 - SIM card (optional, see leaet)
(*) According to the KIT purchased, check the information on the side of the pack

04
USER MANUAL MI004913-E
1 - INTRODUCTION: PRODUCT DESCRIPTION
MyBoatisaexiblecontrolsystemconsistingofasmartcontrolunitandwirelessmonitoringsensorsforthe
remotecontrolandalarmmanagementinrealtimeofyachts,boatsingeneralandeet.Thesystemisbasedon
aCloudplatformoeredbySenecas.r.l.(https://cloud.seneca.it).Thepriceoftheproductincludesthesubscrip-
tiontotheMyBoatserviceforthersttwoyearsfromproductactivation.Forinformationandrenewalcostsofthe
service, go to
www.seneca.it/MyBoat
.
MyBoatisaserviceoeringmanyfunctionsusefultomonitoryourboatthroughimmediateconsultationandthe
practicaluseofbothbrowserandmobileapp.UsingtheMyBoatapp,availableintheAppleandAndroidstores,
youcancheckyourboatwhilemoving,verifythestateofthesensorsandbewarnedinrealtimeincaseofan
alarm(pushnotications,SMSoremail).
AswellasmanagingthecommunicationwiththesensorsandtheSENECAcloudplatform,thecontrolunitisset
fortheadvancedcongurationandoptionalremotecontrolof4digitalinputs,1timedrelayoutput(e.g.siren),1
non-timedrelayoutput(auxiliary),1analogueinputforservicebatterysensor(alreadywiredtothecontrolunit
powersupply)and1fuellevelanalogueinput.Fordetailsontheadvancedconguration,refertochapter5.
SENECA makes available various types of kits consisting of various sensors to monitor: the boat access points, the
state of the engine compartment, the state of the service, engine and general batteries, the current position of the
boat,thewaterlevelinthebilgesandthetemperaturebothinthecabinandinthebilge.
1 - INTRODUCTION: MYBOAT CONTROL UNIT
MyBoat 11-6
MyBoat 13-8
DOCK
BILGE1 BILGE2
The images and diagrams shown must be considered as indicative and not binding.
SERVICES
ENGINES ENGINES ENGINES HATCH 1 HATCH 2

05
USER MANUAL MI004913-E
1 - INTRODUCTION: PRODUCT DESCRIPTION
MyBoat control unit
The MyBoat control unit is a product
derived from SENECA MyAlarm3. Remote
alarm, telemetry and datalogging industrial
unit.
Technical characteristics:
• DisplayLCD128x32Dots
• RechargeableLi-Iobuerbattery,upto
8 hours’ autonomy
• ReplaceableGSM/GPRS/GPSantenna
on SMA connector
• SlotforminiSIM(15x25mm)
• GPSinternalmodulewithbuilt-inan-
tenna(externalA-GPSantennaavaila-
ble as an option)
• ON/OFFkeyanddisplayscrollkey
• StatusLED:devicepower/status,GSM/
GPRS status
• SlotformicroSDcard(foranyrm-
wareupdateanddeviceconguration
toaccessthe2Gnetworkthrougha
SIMsuppliedbythebestknownpro-
viders)
• USB micro port (reserved)
Advanced technical characteristics:
• 4 digital inputs to control electrical
devices
• 1 analogue input for supply voltage
reading
• 1 analogue input for fuel check
• 1 timed relay digital output (e.g. siren
or bilge pump)
• 1 non-timed relay output
Power supply for cigarette lighter plug
1 - INTRODUCTION: MYBOAT CONTROL UNIT
MyBoat control unit
Assembly detail onto DIN rail
forwalltting.Forcorrect
installation,followinstructions
on page 06.

06
USER MANUAL MI004913-E
Thesensorsarewirelessradiode-
viceswithIP20casethatcommuni-
catewiththeMyBoat
control unit using 868 Mhz radio
frequency.Theyarettedwith3V
CR2 batteries guaranteeing their
operation for about 1 year (*). With
the MyBoat app, you can monitor
the state of the batteries of the
individual sensors, to foresee their
replacement.
The sensors integrate the anti-tam-
pering function and can be 3 types:
• magnetic for access control
• level for bilge control
• with“faston”connectorsand
fuse to control the battery volt-
age.
Frontviewofamagneticsensor Bilgewaterleveldetector
Access control sensor magnet
1 - INTRODUCTION: MONITORING SENSORS
Type S sensors:
1 - INTRODUCTION: SENSOR REPRESENTATION IN THE HOME SCREEN
(*) Estimated life under normal operating conditions
BackviewwithIDlabel
Frontviewofalevelsensor
Engine battery status and charge and generator
battery detector Access control sensor type 2 magnet

07
USER MANUAL MI004913-E
1 - INTRODUCTION: MONITORING SENSORS
1 - INTRODUCTION: SENSOR REPRESENTATION IN THE HOME SCREEN
Main screen
Boat access control
Engine access control
Bilge 1 control
Generator battery control
Engine battery control
S1
S2
S3
S4
S5
S6
S7
S8
Bilge 2 control
Hatch 1 control
Hatch 2 control
ENABLED DISABLED ALARM
S1
S2
S3
S4
S5
S6
S7 S8
C1
C1
Monitoring the status of the service
battery takes place via the MyBoat
controlunitanditspowersupply
connector. With this it is possible to
detect the status and voltage of the
service battery it is connected to.
ICON COLOUR KEY
N.B.:
Thewarningaboutcabinaccessoren-
ginecompartmentopeningisalwaysin
real time.
Temperature detection takes place every
15 minutes. In case of variation in sta-
tus, the alarm is given in real time.
Battery voltage detection takes place
every 15 minutes. In case of variation in
status, the alarm is given in real time.
Thebilgewaterlevelsensorsignalsthe
alarminrealtime.Ifthereisnowaterin
the bilge, the alarm is deactivated after
15 minutes.
Ifasensordoesnotcommunicatewith
the control unit for over 100 minutes, all
thealarmsoftheinvolvedsensorwillbe
activated.

08
USER MANUAL MI004913-E
2 - INSTALLATION: INSTALLATION OF THE MYBOAT CONTROL UNIT
For optimum reception of the GPS
signal given by satellites, it is better
to place the MyBoat horizontally on
a surface in an area not covered
by metal structures. If this is not
possible,anoptionalexternalanten-
nawith3mcable(codeA-GPS)is
available.
2 - INSTALLATION: REPLACING THE SENSOR BATTERY
Figure 2
Theupdateofthecontrolunitrm-
wareispossibleviathemicroSD
cardsupplied.Followthefollowing
procedure:
1. CopytheleFW.BINinthemain
folder of the micro SD card;
2. Switchthecontroluniton(***).
3. Insert the micro SD card into
the MyBoat control unit;
4. Waitforthemessageconrming
theupdateofthermware;
5. Press“OK”andwaitforinstal-
lationtocompletewiththeunit
restarting;
6. Thecontrolunitwritesthenew
rmwareontheashmemory
during this phase.
N.B. In order to guarantee the
MyBoatcontrolunitworkscorrect-
ly, THE CONTENT OF THE SD CARD
MUST NOT BE REMOVED.
MyBoatisttedwithanON/OFF
PWR key positioned in the LH top
corner (Figure 3).
Figure 3
N.B.:
First startup procedure:
FW update procedure:
Switchingonandscrollkeys:
1. Insert the mini SIM card into the
switched-oMyBoatcontrolunit
(*);
2. InserttheSDcard(seegure2);
3. ConnecttheGSM/GPRSantenna
(**);
4. Connectthepowersupplyto
theterminalblockfollowingthe
instructions on page 29;
5. Insert the cigarette lighter plug
toswitchtheMyBoatcontrol
unit on.
Toconrmtherststartupprocedure
is correct, the GSM LED will start
ashing3timesasecond.
(**)ConnectanyA-GPSoptionalantennafollowingthe
proceduresuppliedwiththeantenna.
(*) Ensure you have removed the locking PIN during
theswitch-on phase using another device, and at the
sametimecheckdataconnectionisworkingproperly.
(***)Ensurethecontrolunitispoweredviatheciga-
rette lighter cable supplied.
Toswitchito,keepthePWRkey
pressedforafewseconds.
ThedeviceisttedwithaSCRkey,
in the RH top corner. Pressing this
key displays the parameters.
Altri manuali per MyBoat
2
Indice
Manuali Attrezzatura nautica popolari di altre marche

Dowco
Dowco V322 CC - 2019 Manuale utente

Humphree
Humphree HCS-5 Manuale utente

Vetus
Vetus BOW4512D Scheda tecnica

Dock Doctors
Dock Doctors SLIDING BOARDING STEP Manuale utente

Mastervolt
Mastervolt Mass Combi 12/2000-100 Istruzioni operative originali

Zattini Group
Zattini Group bamar BOXTRON E14S Guida utente