4
Web Site : http://www.sengate.com
E-Mail : service @ sengate.com
Designing / Manufacturing
Taiwan Security Net Co., Ltd. Designing / Manufacturing
Taiwan Security Net Co., Ltd.
No.4-46, Fengren Rd., Renwu Dist., Kaohsiung City 814, Taiwan
TEL 886-7-3721111~4 FAX 886-7-3728650 : :
No:A059B02-01
Unit : (inch mm)
2.22 56.5)" (
4.13 (104.85)"
3.31 84.0)" (
2.78 70.6)" (
5.14 130.6)" (
1.79 (45.6)"
2.76 (70.0)"
4.72 120.0)" (
3.29 83.5)" (
2.95 75.0)" (
1.73 44.0)" (
1.14 29.0)" (
PH-15FA (FLUSH Mount)
PH-15SA (SURFACE Mount)
PH-15FA PH-15SA
150ms (100~200ms)
-25℃ ~ +55℃
2.76"x 4.72"x 1.73"
(70.0x120.0x44.0 mm)
2.78"x 5.14"x 2.22"
(70.6x130.6x56.5 mm)
Indoor / Surface Mount
6
TROUBLE-SHOOTING GUIDE:
7 8 DIMENSIONS:SPECIFICATION:
CONDITION POSSIBLE CAUSE REMEDY
Operation LED doesn’t light.
(Transmitter)
Receiver
when
Alarm LED does not light
the beam is broken.
Receiver Alarm LED Alarm stays lit.
1. Disruption of power or inadequate power.
2. Bad wiring connection or broken wire, short.
1. Correct Power source.
2. Check and correct wiring.
1. Disruption of power or inadequate power.
2. Bad wiring connection or broken wire, short.
3. Reflection of beam is flooding receiver and sent into
the receiver.
1. Correct Power source.
2. Check and correct wiring.
3. Remove reflecting object or change the
installation location.
1. Bad wiring Connection.
2. Unstable power source.
3. Shading object between Transmitter and Receiver.
4. The wiring of power machine is located nearby
Transmitter and Receiver.
5. Unstable installation of Transmitter and Receiver.
6. Optics of units are soiled.
7. Improper alignment.
1. Check and correct wiring.
2. Stabilize supply voltage.
3. Check and remove any possible obstacles.
4. Change environments or place for installation to
avoid the interference source.
5. Looking for proper installation location.
6. Clean the optics with soft cloth.
7. Check and re-adjust.
Intermittent Alarm.
1. Alignment is off.
2. Shading object between Transmitter and Receiver.
3. Optics of units are soiled.
1. Check and adjust.
2. Check and remove any possible obstacles.
3. Clean the optics with a soft cloth.
MODEL NO.
Supply Voltage
Standard Accessories
Environment Humidity
Ambient Temperature
Detection System
Response Time
Interruption Time
Alarm Output
Tamper Output
Indicator LED
Functions
Wiring
Beam Adjustment
Mounting Position
Weight
Dimension (W X H X D)
Transmitter:Green Operation LED lights on when
with power on.
cover is
opened
Receiver:Red Alarm LED lights on when an alarm is initiated.
Yellow Sensitive LED lights on when beam reception
is attenuated.
Both Yellow and Red LED should be off as correct
installation.
Horizontal Vertical ± 90° ± 5°
Please Note:
1.This sensor is designed to detect intrusion and initiate an alarm; it is not a burglary-preventing device.
2.We are not responsible for damage, injury or losses caused by accident, theft,
misuse, abnormal usage, faulty installation or improper maintenance.
3.Specifications and design are subject to change without prior notice.
Acts of God (including inductive surge by lightning), abuse,
6.9oz (195g) 9.7oz (275g)
Indoor / Outdoor / Flush Mount
Screw 5/32" x 1
Attenuation sheet X 1 pc
" X 4 pcs
Horizontal Vertical ± 15° ± 5°
AWG26 Wiring Terminals
95% (Max.)
3- step Alignment LED.
Dry Contact NC. 0.2A/30VDC
None
Dry contact relay NC. / NO. 0.2A / 30VDC
(When the beam is blocked.)
1second
Pulsed Infrared 1000pps
Infrared beam interruption system
10.5V~28VCD (Non-Polarity)
Transmitter 12mA (16mA Max.)
Receiver 24mA (26mA Max.)
150 M
Indoor 15 M
Detection Range
Tenfold Distance
Beam Characteristics
Current Consumption