SENSIT Technologies IRED Manuale utente

INFRARED ETHANE DETECTOR
SENSIT®IRED
INSTRUCTION MANUAL
READ AND UNDERSTAND INSTRUCTIONS BEFORE USE
851 Transport Drive
Valparaiso, IN 46383-8432
Phone: 888 473 6748
219 465 2700
Fax: 219 465 2701
Email: info@gasleaksensors.com
Web: www.gasleaksensors.com

Warnings:
• Topreventignitionofammableorcombustibleatmospheresdisconnectpowerbeforeservicinginanarea
knowntobefreeofcombustiblegases.
• Chargebatterypackinanareaknowntobefreeofcombustiblegases.
• UseonlySensitTechnologiesbatterypack.
• Servicemayonlybeperformedbyfactoryauthorizedservicetechnicians
• Notforuseinenvironmentsgreaterthan21%oxygen.
Safety Precautions:
• Readandunderstandinstructionspriortouse.
• AlwaysstarttheIREDinanareaknowntobegasfree.
• Tamperingwiththisproductmayvoidthewarranty.
• UseonlySensitTechnologiesapprovedpartsandaccessories.
• Neveruseaninstrumentknowntobedamaged,operatingunusually,oroutofcalibration.
Tips:
• Besurebatteryischargedbeforeeachdaysuse.
• Checkprobefordamagebeforeeachuse.
• Checkltersbeforeeachdaysuse.
For further information contact Sensit Technologies.
SensitTechnologies
851TransportDrive
Valparaiso,Indiana
46383
USA
Tel:219/465-2700
Fax:219/465-2701
Email:[email protected]
Web:www.gasleaksensors.com

TABLE OF CONTENTS
Section Title Page
GeneralDescription......................................................4
PartsandAccessories..................................................5
ProductSpecications..................................................6
ProductFeatures..........................................................6
ElectronicFeatures......................................................7
DisplayFeatures...........................................................7
HousingFeatures.........................................................8
Inlets,Filters.................................................................9
OperationandFieldUse...............................................10-11
BumpTest.....................................................................12
Calibration....................................................................13
UserMenu....................................................................14
ExpertMenu.................................................................15
Ethane(C2H6)toMethane(CH4)RatioProcedure.... 16-17
Methane/EthaneRatioChart.......................................18
Warranty.......................................................................BackCover

4
General Description
TheSENSIT®InfraredEthaneDectector,referredtoas“IRED”,isdesignedtodetectthepresenceof
ethanegasinamethanegassample.TheIREDcandetect250partsperbillion(ppb)upto500ppm
ethane.TheIREDisusedtodetermineifmethanedetectedintherangeof50-2000ppmisofsimilar
make-uptothatofpipelinegas(whichcontainsethane)orisnaturallyoccurringmethanefromother
sourcessuchasorganicdecay.TheIREDisnotdesignedforhighconcentrationsordeterminingactual
ethanecontentfromwithinapipeline.
TheIREDsensesgasusingInfrared(IR)AbsorptionSpectroscopyincombinationwithanelectronic
narrowband-passlter.Thistechnologyutilizesaninfraredlightsourcewithanoutputthatischanged
when certain gases absorb the light output. The lter only allows specic light wavelengths to be
monitoredandmeasured.TheconcentrationofgasisproportionaltotheamountofspecicIRlight
absorbedandisdisplayedinPPBorPPM.
TheIREDhasalargedisplay indicatingbothsustainedandpeakreading concentrationsandother
instrumentfunctions.Aninternalpumpprovidesrapidsamplingintothedetectionchamber.Bluetooth
data transmission provides communication of real time and stored data. Optional GPS with Data
Loggingallowforfurtherrecordingoftime,dateandlocationdata.
Patented 1. Press Power
2. Wait for Automatic Zeroing
3. Begin to Use
TO OPERATE:
ERROR
LED
INFRARED
COMMUNICATIONS
GRAPHIC DISPLAY
SOUNDER
FILTER
OPERATION
BUTTONS
BACK
LIGHT
SENSOR
“D”
RING
TELESCOPIC
SURVEY BOOT
and PROBE ROD
READY
LED

5
Parts and Accessories
Standard Accessories
CompactCarryingCase Part#872-00021
TelescopicSurveyProbe Part#883-00029
InstrumentHandleStrap Part#360-00464
HotSwapVehicleBattery Part#871-00030
UniversalWallCharger Part#871-00025
BatteryDoorRemovalTool Part#360-00249
HydrophobicFilterRingAssembly(10Pack) Part#873-00033
SurveyProbeFilter(Blue)(1Filter) Part#360-00064
InstructionManual Part#750-00061
ForIREDw/GPS:
SmartLinkLogViewerSoftware Part#870-00040
SmartLinkInstallationGuide Part#750-00051
SENSIT®IRED Calibration Kit
IRED Calibration Kit Part # 881-00100
Kit includes:
(1) Regulator, (1) Cal Adapter
(1) 100pm Ethane/Nitrogen 58L
SENSIT®IRED Replacement Cylinders
100ppm Ethane/Nitrogen 58L Part # 315-120010
2.5% Methane/Air 103 Liter
SENSIT®IRED Bump Test Kit
IRED Bump Test Kit Part # 881-00101
Kit includes:
(1) Regulator, (1) Cal Adapter,
(1) 1000ppm CH4/10ppm Ethane 58L
SENSIT®IRED Replacement Cylinder for Bump Test
1000ppm CH4/10ppm Ethane 58L Part # 315-120005
2.5% Methane/Air 10

6
Product Specications
Operational Specications
Temperature: -4°Fto122°F(-20°Cto50°C)
DutyCycle: 6hours
Testtime: 40seconds(Afterwarmupandzeroing)
Display: Visual–Backlightdisplay
Visual–Concentration,TestStatus,InstructionalPrompts
Visual–Failureindicators
Power: LithiumIonRechargeablebatterypack
OptionalVehiclechargeradapter
PumpFlow: 1.0lpm
SampleSizeRange: 50-2000ppmMethane
Physical Specications
Size: 11.625”x5.25”x8.375”(Approximate)(11.6cmx13.3cmx21.3cm)
Weight: 7.41Lbs(7.41kg)
Construction: Aluminum/ABSPlastic
Sensor Specications
IRSensor: Method:AdvancedInfraredAbsorptionSpectroscopy
DetectionRange250ppb–500ppm
Warmup<30min
Calibrationrequired-3months
Product Features
• TheIREDisconstructedofdurableABSPlastic
• ThehousingisdesignedtomeetIP54protection
• Batterypackisdesignedforeasyeldreplacement
• FieldorSmartCalcalibrationiseasilyperformed
• Externalltersareinexpensiveeasytochange
• TheLCDdisplayiseasytoread
• TheIREDusesasimple“SensitStyle”userinterface
• CommunicationwithotherdevicesiseasywithBluetoothinterface
• RealtimeGPSisoptional
• Dataloggingofresultsfordownloadtoprinterorcomputer
• Bluetoothandinfraredcommunication

7
Electronic Features
User Interface
Theuserinterfaceincludesthefollowingfeatures:
• Threebuttonoperation
• LEDStatusindicators
• Sounder
• Photocell(automaticbacklighting)
• IRcommunicationport
• LCD
Button Operation
TheSensitIREDisoperatedwith
theuseofthreebuttonsbelow
thedisplay.
TheyarelabeledA,B,C.
The“A”button:
• Activates/Deactivatestheinstrument
• AcknowledgeTestFuction
• AccessSmart-CalCalibrationFunctions
The“B”button:
• StartsOperationFunctions
The“C”button:
• AccessMenu
• PrintResults
• Activates/DeactivatePump
Display Features
Thedisplayprovidesallinformationincluding:
• EthaneconcentrationinPPBandPPM
• FlowBlockedIndicator
• GPSactivationandcoordinates
• WarningMenu

8
Housing Features
Battery Pack
Thebatterypackislocatedonthebacksideoftheinstrument
housing.ThebatteriesareLithiumIonrechargeableandonly
availablefromSensitTechnologies.
Toremovethebatterypackturntheretainingscrews¼turn.
Pullthebottomofthepackawayfromthemainhousing.The
batterypackmaybechargedwhilestillinthemainhousing,
buttheinstrumentwillnotbeabletobeusedduringthistime.
Toreplace,slidethetoptabsofthebatterypackintothe
retainersatthetopofthemainhousing.Pushthebottominto
placeandturnandlocktheretainingscrews.
ChargerConnection
OnOtherSide
ChargeComplete
(Green)
Charging
(Red)
Status
(Yellow)
ThebatterypackhasLEDstoindicatechargestatus.Chargingshouldonlybeperformedinanarea
knowntobefreeofcombustiblegases.
Thebatterypackmayalsobechargedwhileoperatinginavehicle.Connectthe12vDCadapterinto
thevehiclepoweroutletandtheexternalportonthebatteryhousing.Thiscanbeconnectedand
disconnectedwhiletheIREDisoperating.
Whenthechargerisdisconnected,thewords“WARMUP”,“PLEASEWAIT”(ashing)aredisplayed
anda180secondcountdownisstarted/displayed.Theusercannotperformameasurmentuntilthe
countdownexpires.Theinstrumentwillonlyoperatewhenonbatterypower.

9
Gas Inlet and Outlet
Locatedonthefrontofthemainhousingisthegasinletand
outlet.Botharettedwithluer-styleconnectionsforeasy
connectiontoprobeaccessories.
Thecenterconnectionisthegasinlet.Totherightistheoutlet.
Donotblockgasoutlet.
Handle Strap / Shoulder Strap attachment
“D”ringsarelocatedoneachsideofthemainhousingforhandlestrap/shoulderstrap
attachments.Clipsonthestrapwillattachsecurely.
Hydrophobic Filter Assembly
WARNING:Donotoperatewithoutproperlter.Damagemay
occurtothepumpandotherinternalparts.Onlychangelter
withpumporinstrumentoff.
Thegasinletisprotectedbya
hydrophobiclter.
Toreplacethelter:
1. Detachanyprobeassembly
2. Twistandremoveltercap
3. Removeandreplacelterdisc
4. Check“O”ringinsidecap
5. Replaceltercap
6. Performowblocktest
Additionalltersarelocatedineachoftheaccessory
probeassemblies.

10
Operation and Field Use
1. ToactivatetheinstrumentpressandholdthePOWER(A)buttonuntilthedisplayilluminates.
Thefollowingwarmupsequencewilloccuronthedisplay(a-g):
a. SensitLogowillappear
b. SystemCheck
i. Failureswillbelisted,ifanyoccur
1. PressingtheAbuttonwillturnofftheinstrument
2. PressingtheBbuttonwilldisplaythenexterrorifmorethanonehasoccurred
3. PressingtheCbuttonwillskippasttheerrortocontinuewarmup.Apassword
isrequiredtoskiptheerrormessage.Wrongpasswordwillcausetheerror
messagescreentobedisplayed.
ii. UsetheBand/orCbuttontoadjustthepassword.
iii. PresstheAbuttontoaccepttheentry.
c. Serialnumber,SoftwareRevision,DateandTime.
d. FlowCheck
i. IftheFlowCheckissuccessful,PASSEDwillbedisplayed.
ii. IftheFlowCheckisunsuccessful,ensurethatnothingisobstructingtheinletor
exhaust,andchecktheintegrityofthehydrophobiclter.
e. Warmupisindicated“PLEASEWAIT”witha600secondcountdowntimer.Thecountdown
timerwillbeginafteraninitialwarmupof5-10minutes.
f. CellCheck
i. Thisisa5stepprocessthatteststheintegrityoftheinternalcell.
ii. Theprocesstakesapproximately7.5minutestocomplete.
1. CleanAir
2. MethaneCellIn
3. TemperatureAdjustment
4. MethaneCellIn
5. CleanAir
iii. IftheCellCheckfails,restarttheinstrument.
Iftheprocessisunabletosuccessfullycomplete,serviceisrequired.
g. CalibrationduedateindicatingwhencalibrationwillneedtobedoneorPASTDUE
indicatingcalibrationdatehasbeenexceeded.Ifcalibrationisrequired:
i. PressingtheAbuttonwillturnofftheinstrument
ii. PressingtheBbuttonwillbeginthecalibrationprocess
iii. PressingtheCbuttonwillskippastthecalibrationrequiredmessagetocontinuewarmup.
h AutoBumptestfunctiontovalidatesensitivitytoethane(ifoptionisactivated)
i. PressingtheAbuttonwillturnofftheinstrument.
ii. PressingtheBbuttonwillbeginthebumptestprocess.
iii. PressingtheCbuttonwillskippastthebumptestrequirementtocontinuewarmup.
i. Workingmodedisplayindicatedby“READYFORMEASUREMENT”onthedisplay
andreadyLEDillunimated.
Altri manuali per IRED
3
Indice
Altri manuali SENSIT Technologies Rilevatore di gas

SENSIT Technologies
SENSIT Technologies GAS-TRAC LZ-30 Manuale utente

SENSIT Technologies
SENSIT Technologies IRED Manuale utente

SENSIT Technologies
SENSIT Technologies GOLD G3 Manuale utente

SENSIT Technologies
SENSIT Technologies VMD Istruzioni operative

SENSIT Technologies
SENSIT Technologies 906-00000-08 Manuale utente

SENSIT Technologies
SENSIT Technologies Gas Trac LZ-30 Manuale di programmazione

SENSIT Technologies
SENSIT Technologies GAS-TRAC LZ-30 Manuale utente