SENSTAR 03RM Istruzioni operative originali

03RM
Personal Alarm System
T0DA0202-001, Rev A
First edition
September 15, 2009
03RM
Installation &
Operation Guide

Senstar Corporation
119 John Cavanaugh Drive
Carp, Ontario
Canada K0A 1L0
Tel: +1 (613)-839-5572
Fax: +1 (613)-839-5830
Website: www.senstar.com
Email address: info@senstar.com
T0DA0202-001, Rev A
First edition
September 15, 2009
Senstar is a registered trademark, and the Senstar logo is a trademark of Senstar Corporation. Product names and Company
names used in this document are included for identification purposes only, and are the property of, and may be trademarks of,
their respective owners. Copyright © 2009 Senstar Corporation. All rights reserved. Printed in Canada.
The information provided in this guide has been prepared by Senstar Corporation to the best of its ability. Senstar Corporation is
not responsible for any damage or accidents that may occur due to errors or omissions in this guide. Senstar Corporation is not
liable for any damages, or incidental consequences, arising from the use of, or the inability to use, the software and equipment
described in this guide. Senstar Corporation is not responsible for any damage or accidents that may occur due to information
about items of equipment or components manufactured by other companies. Features and specifications are subject to change
without notice. Any changes or modifications to the software or equipment that are not expressly approved by Senstar
Corporation void the manufacturer’s warranty, and could void the user’s authority to operate the equipment.
Senstar’s Quality Management System is IS0 9001:2000 registered.

Limited Warranty
a) The Company warrants that the electronic components of the products manufactured by the Company are free from all
manufacturing defects. The Company's warranty does not extend to the performance of the products, which may vary depending
on environmental conditions, use and installation practices. The Company's liability under this warranty shall be limited to, at its
option, either repairing or replacing the defective components of the products or granting a credit for the products or parts thereof.
The Company's liability shall apply only to products which are returned to the factory or authorized repair point, transportation
charges prepaid by the Buyer within one (1) year from the shipment date of the product from the Company and which are, after
examination, disclosed to Company's satisfaction to be defective due to defects in workmanship and/or materials. This warranty
shall not apply to any products which have been installed, repaired or altered by other than personnel certified by the Company, or
to products which have been subject to physical or electrical abuse, misuse, or improper storage or to products which have not
been used or maintained in compliance with any applicable recommendations of the Company. This warranty does not apply to
any parts or components of the products, which are normally consumed in operation, including but not limited to batteries, fuses
and light bulbs.
b) The Company specifically disclaims any and all warranties, expressed or implied, including but not limited to any warranties
or merchantability or fitness for a particular purpose. Under no circumstances be it due to a breach ofwarranty or any other
cause arising out of the performance or non-performance of the Product shall the Company be liable to the Buyer for incidental or
consequential damages, including but not limited to: lost profits, loss of property due to the freight, plant downtimes, or suits by
third parties.

iii
TABLE OF CONTENTS
WARRANTY ...................................................................................................................... ii
PROPRIETARY INFORMATION.................................................................................... ii
1.0 GENERAL DESCRIPTION........................................................................... 1-1
1.1 Purpose ............................................................................................ 1-1
1.2 Features............................................................................................ 1-1
1.3 Specifications................................................................................... 1-2
2.0 THEORY OF OPERATION.......................................................................... 2-1
2.1 System Concept.............................................................................. 2-1
2.2 Transmitter (PAT/S) (PAT/C)........................................................ 2-1
2.3 Receiver (O3RM)............................................................................ 2-3
3.0 RECEIVER PLACEMENT............................................................................ 3-1
3.1 Receiver Placement..........................................................................3-1
4.0 INSTALLATION................................................................................................4-1
4.1 General...............................................................................................4-1
4.2 Receiver (O3RM) Installation..........................................................4-1
5.0 SYSTEM TESTING .........................................................................................5-1
5.1 Final Tests..........................................................................................5-1
5.2 Alarm Sensitivity Adjustment...........................................................5-4
5.3 Audio Volume Adjustment...............................................................5-5
6.0 MAINTENANCE...............................................................................................6-1
6.1 Periodic Tests....................................................................................6-1
6.2 Cleaning / Adjustment......................................................................6-1
6.3 Special Requirements......................................................................6-1
7.0 TROUBLESHOOTING....................................................................................7-1
7.1 Systematic Testing............................................................................7-1
7.2 Problem Identification and Resolution...........................................7-1
APPENDIX Personal Alarm Transmitter Operation Guide

iv
LIST OF FIGURES
Figure 2-1 Transmitter Unit.....................................................................................2-2
Figure 4-1 03RM Mounting Dimensions ...............................................................4-2
Figure 4-2 Magnet Location on Receiver Back Box............................................4-3
Figure 4-3 Receiver Connections and Alarm Jumpers.......................................4-5
Figure 5-1 Audio Volume Adjustment....................................................................5-5
LIST OF TABLES
Table 4-2 03RM Receiver and Jumper Settings................................................4-6
Table 4-3 03RM Wiring Chart................................................................................4-8
Table 5-1 Personal Alarm System--Test Report................................................5-3
Table 7-1 Troubleshooting Guidelines.................................................................7-2

v
This page intentionally left blank.

1-1
1.0 GENERAL DESCRIPTION
1.1 Purpose
The MSI Personal Alarm Receiver/Transmitter system is specifically
designed to provide reliable yet economical protection for roving
personnel. The 03RM ultrasonic receivers are installed throughout the
protected facility. Personnel carry the battery-powered, ultrasonic
Personal Alarm Transmitter. A person in trouble need only press the
alarm button on the transmitter to activate the nearest receiver and
summon help quickly. This basic ultrasonic transmitter and receiver alarm
locating system can be used with a variety of annunciation and control
equipment as part of a complete personal alarm system.
1.2 Features
Portable Transmitter (PAT/S)
Latching push button activation.
Rugged case molded from Lexan plastic.
Unique reversible pocket clip.
Leather holster for wearing on belt (optional).
Continuous transmission on activation assures positive reception.
Low-battery indicator
Man-down option
Portable Transmitter (PAT/C)
Latching push button activation.
Keeper pin activation
Compact size
Rugged case molded from Lexan plastic.
Unique stainless steel pocket clip.
Continuous transmission on activation assures positive reception.
Low-battery indicator
3 point lanyard
Receiver (03RM)
Rugged tamperproof design.
Simplified mounting to a standard electrical box.
Up to 50-foot receiving range.
Red LED alarm lamp.
Remote self-test

1-2
1.3 Specifications
Transmitter PAT/S (standard size)
Circuit components 100% solid state, conformal coated
circuit boards
Dimensions 3.8"H x 2.4"W x .9"D
Weight 4 oz.
Battery life 100 hours of continuous transmitting
time, low battery monitor
Activation Latching, push/push switch (“man-down”
optional) (“pull pin” optional)
Battery type Lithium, 9V
Battery access Compartment accessible with tool
provided by manufacturer
Transmitter PAT/C (compact size)
Circuit components 100% solid state, conformal coated
circuit boards
Dimensions 2.35"H x 1.5"W x .8"D
Weight 1.5 oz.
Battery life Approximately 1 year, low battery
monitor
Activation Latching, push button switch and pull
activation
Battery type Lithium, 9V battery pack
Battery access Compartment accessible with security
hex key provided
Receiver (03RM)
4 models available: 03RM - standard indoor unit
03RM/IV - includes integrated video
camera
03RM/WP - weatherproof unit for indoor
or outdoor use

1-3
03RM/WPH - weatherproof unit with
thermostatically controlled heater for low
temperature outdoor use
Circuit components 100% solid state, conformal coated
circuit boards
Size Fits 4” square x 2.12 deep double-gang
box with or without plaster ring (requires
3.5” x 2.75” opening)
03RM/WP and 03RM/WPH supplied
with two gang, weather proof box with
gasket
Mounting Tamper-resistant screws (furnished)
Power requirement 03RM, 03RM/WP: 12 VDC to 24 VDC
(max) 40 mA 03RM/IV: 12 VDC to 24
VDC (max), 120 mA 03RM/WPH:
Receiver unit 12 VDC to 24 VDC (max)
40 mA, Heater unit 12 VDC to 24 VDC
(max) from separate supply, .5 A to 1.0 A
depending on voltage
Connection Removable plug-in terminal block
Supervision Relay activation on loss of power
Enclosure tamper switch
Range Variable -- up to 50 ft.
Alarm output Relay contact. Configurable as normally
open, normally closed, supervised or
non-supervised.
Dry Contact Relay Red LED on face
plate illuminates on alarm.
Aux Alarm Contact Normally Closed (NC) or Normally Open
(NO) rated 1 Amp, 30 VDC
Audio assessment Pre-amplified audio is provided
Moisture Barrier Installed in 03RM/WP and 03RM/WPH
units
Finish Stainless steel
Tamper Switch 2 NC magnetic reed switches (.25 Amp,
12 VDC)
Self-Test Alarm is activated when 6 to 24 VDC is
applied at Test terminal (relative to
power return) for a minimum of 3
seconds

Indice
Altri manuali SENSTAR Sistema di sicurezza
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente