Sentera 6X Manuale utente

6X Multispectral Sensor
Reflectance Panel
User Guide
Engineered in Minneapolis, MN, USA
August 13, 2020
Version 1.0

6X Multispectral Sensor User Guide
www.sentera.com Page 2 of 13 Updated August 13, 2020
844.SENTERA © 2020 Sentera, LLC. All rights reserved.
Copyright © 2020. All rights reserved.
Trademark Notice
6X and Incident Light Sensor are registered trademarks of Sentera. Other featured words or symbols, used to identify the
source of goods and services, may be the trademarks of their respective owners.
Third-Party Content, Products, and Services Disclaimer
This software and documentation may provide access to or information on content, products, and services from third parties.
Sentera is not responsible for and expressly disclaim all warranties of any kind with respect to third-party content, products,
and services. Sentera will not be responsible for any loss, costs, or damages incurred due to your access to or use of third-party
content, products, or services.
The information contained herein is subject to change without notice and is not warranted to be error-free. If you find any
errors, please report them to us in writing.

6X Multispectral Sensor Reflectance Panel User Guide
www.sentera.com Page 3 of 13 Updated August 13, 2020
844.SENTERA © 2020 Sentera, LLC. All rights reserved.
Contents
1 Introduction .......................................................................................................................................... 4
2 Reflectance Panel Overview ................................................................................................................. 4
3 Capture Reflectance Panel Imagery...................................................................................................... 4
3.1 Connect to Laptop......................................................................................................................... 4
3.2 Capture an Image.......................................................................................................................... 8
3.3 Capture Reflectance Panel Images ............................................................................................. 10
4 Support................................................................................................................................................ 13
5 Revision History .................................................................................................................................. 13

6X Multispectral Sensor Reflectance Panel User Guide
www.sentera.com Page 4 of 13 Updated August 13, 2020
844.SENTERA © 2020 Sentera, LLC. All rights reserved.
1Introduction
Welcome to the 6X Multispectral Sensor Reflectance Panel User Guide. This user guide is designed to
provide documentation for people who will use 6X on a professional basis. This guide is targeted to
users with an understanding of multispectral imaging and image processing.
2Reflectance Panel Overview
A reflectance panel has known spectral properties and can be used to convert imagery to reflectance
values under different lighting conditions. The process of converting imagery into reflectance values
allows for time series comparisons of imagery because it normalizes the data for different lighting
conditions.
Note: Reflectance panel images should be captured pre-flight, but if you forget,
the images can be captured post-flight also.
3Capture Reflectance Panel Imagery
The steps to capture reflectance panel imagery include attaching the sensor to a laptop, navigating in a
web browser to the 6x configuration page, and capturing the reflectance panel images.
3.1 Connect to Laptop
To connect to a laptop:
1. Attach 6X sensor and Incident Light Sensor (ILS) sensor onto the drone, as shown in Figure 1.

6X Multispectral Sensor Reflectance Panel User Guide
www.sentera.com Page 5 of 13 Updated August 13, 2020
844.SENTERA © 2020 Sentera, LLC. All rights reserved.
Figure 1: Attach Camera and ILS Sensor
2. Wait for the 6X and ILS sensor LED lights to turn green, indicating a session has started and the
sensor is ready to capture images, as shown in Figure 2.

6X Multispectral Sensor Reflectance Panel User Guide
www.sentera.com Page 8 of 13 Updated August 13, 2020
844.SENTERA © 2020 Sentera, LLC. All rights reserved.
Figure 4: Plug Ethernet into Laptop
3.2 Capture an Image
To capture an image:
1. Open a web browser on the laptop and navigate to the 6X Configuration page http://sentera-
6x.local/., as shown in Figure 5. If that doesn't work try refreshing the page or try navigating to
http://192.168.42.1/.

6X Multispectral Sensor Reflectance Panel User Guide
www.sentera.com Page 9 of 13 Updated August 13, 2020
844.SENTERA © 2020 Sentera, LLC. All rights reserved.
Figure 5: Enter URL
2. To ensure the camera is ready to go, click Capture Image, as shown in Figure 6.
Figure 6: Capture Image Button
3. In File Explorer, navigate to \\sentera-6x.local\ and find the current session folder. Check to make
sure the single image you captured is present, as shown in Figure 7.

6X Multispectral Sensor Reflectance Panel User Guide
www.sentera.com Page 10 of 13 Updated August 13, 2020
844.SENTERA © 2020 Sentera, LLC. All rights reserved.
Figure 7: Captured Image Location
4. Perform a compass calibration or other adjustments as necessary before recording reflectance panel
images.
3.3 Capture Reflectance Panel Images
To record reflectance panel images:
1. In a clear area, open the reflectance panel, only holding it by the edges, and place it on a flat surface
or the ground near the drone, as shown in Figure 8.