Please read before operating your new Air Purier
The air purier draws in room air from the air intake, passes the air through a Pre-
Filter and a HEPA Filter inside of the unit, then discharges the air through the air
outlet. The HEPA Filter can remove 99.97% of dust particles as small as 0.3 microns
that pass through the lter.
Some odors absorbed by the lter may break down over time, resulting in additional
odor. Depending on the usage environment, especially when the product is used in
extreme environments (signicantly more severe than normal household use), this
odor may become strong in a shorter period than expected. If the odor persists, the
lter should be replaced.
NOTE
• The air purier is designed to remove air-suspended dust, but not harmful gases
(for example, carbon monoxide contained in cigarette smoke).
HEPA Filter
Pre-Filter
OM_FP-F30A_EN.indd 2 2015/10/14 10:53:04

ENGLISH
E-1
ENGLISH
Thank you for purchasing the SHARP
Air Purier. Please read this manual carefully.
Before using this product, be sure to read the
section: “Important Safety Instructions.”
After reading this manual, keep it in a
convenient location for future reference.
For your reference, we recommend to keep
this manual in the place where you can read
at any time.
IMPORTANT SAFETY INSTRUCTIONS
..... E-2
PART NAMES...............................................E-4
FILTER INSTALLATION ............................. E-5
OPERATION .................................................E-6
CARE AND MAINTENANCE ..................... E-8
TROUBLESHOOTING ..............................E-10
SPECIFICATIONS...................................... E-11
CONTENTS
FEATURES
Unique Combination of Air Treatment
Technologies
Filtration System + Plasmacluster Ions
TRAPS DUST*
Pre-lter traps dust and other large
airborne particles.
REDUCES POLLEN & MOLD*
HEPA lter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to
the way nature cleans the environment
by emitting a balance of positive and
negative ions.
*When air is drawn through the lter
system.
OM_FP-F30A_EN.indd 1 2015/10/14 10:53:04

E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed,
including the following:
WARNING - To reduce the risk of electric shock, re or injury to persons:
• Read all instructions before using the unit.
• Use only a 220 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the
wall outlet is loosened.
•Periodically remove dust from the power plug.
• Do not insert ngers or foreign objects into the air intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electric shock and/or re from short circuit may occur as a result.
•
Be careful not to damage the power cord, it may cause electric shock, excess heat or
res.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not
using the unit.
Electric shock from bad insulation and/or re from short circuit may occur as a result.
•When cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electric
shock and/or re from a short circuit may result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service
agent, Sharp Authorized Service Centre or similarly qualified person in order to
avoid a hazard.
•Do not operate when using aerosol insecticides or in rooms where there is oily residue,
incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity
conditions, such as a bathroom.
•Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
•Only a Sharp Authorized Service Centre should service this air purifier. Contact the
nearest Service Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
NOTE - Radio or TV Interference
If this air purier should cause interference to radio or television reception, try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
OM_FP-F30A_EN.indd 2 2015/10/14 10:53:04

ENGLISH
E-3
CAUTIONS CONCERNING OPERATION
• Do not block the air intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may
come into contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on the back of the unit when moving it.
• Do not use without the lter installed inside the unit.
•Do not wash and reuse the HEPA lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
INSTALLATION GUIDELINES
•
When using the unit, place it away from equipment utilizing electric waves such as
televisions or radios to avoid electrical interference.
• Avoid using in locations where furniture, fabrics or other items may come in
contact with and restrict the air intake and/or air outlet.
• Avoid using in locations where the unit is exposed to condensation or drastic
temperature changes. Appropriate condition is at room temperature 0 – 35 ºC.
• Place on a stable surface with sucient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack as a result.
•Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper
airow.
The dust collecting performance will be the same even if using the unit 3cm away from
the wall, but place it as far as possible(30cm away recommended) because it may dirty
the wall or oor around.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lter.
OM_FP-F30A_EN.indd 3 2015/10/14 10:53:04

E-4
PART NAMES
13
14
16
2
1
1Main Unit 9 HEPA Filter
2Air Outlet 10 Upper Tabs
3Fan Speed Indicator Lights (green) 11 Back Panel (Pre-Filter)
4MODE Button / LIGHT ON/OFF Button (Press 3 sec.) 12 Bottom Tabs
5Plasmacluster Ion Indicator Light (blue) 13 Handle
6Plasmacluster Ion ON/OFF Button 14 Date Label
7POWER ON/OFF Button 15 Power Cord
8CLEAN ION SHOWER Button /
CLEAN ION SHOWER indicator Light (green) 16 Plug
FRONT
BACK
4
6
7
8
3
15
9
10
11
12
5
OM_FP-F30A_EN.indd 4 2015/10/14 10:53:04

ENGLISH
E-5
FILTER INSTALLATION
To maintain the quality of the lter, it is installed in the main unit and packed in plastic
bag. Be sure to remove the lter from the plastic bag before using the unit.
1
Remove the Back Panel.
2
Remove the plastic bag and
take out the Filter.
3
Place the Filter inside the main
unit.
Do not install the lter backwards or the
unit will not operate properly.
Upper Tabs
• Do not operate the unit without the lter.
Date Label
Pull Push
Be sure to remove the power plug
from the wall outlet.
4Replace the Back Panel to the
main unit.
5Fill in the usage start date on the
Date Label.
Use the date as a guide for the lter
replacement schedule.
Bottom Tabs
OM_FP-F30A_EN.indd 5 2015/10/14 10:53:05

E-6
OPERATION
MED MAX SLEEP
Releases high-density Plasmacluster ions and discharges strong air ow for 60 minutes.
CLEAN AIR
START
•Select the desired fan speed.
•Unless the power cord has been unplugged,
the operation starts in the previous mode it
was operated in.
STOP
CLEAN ION SHOWER
START
• If Plasmacluster Ion is OFF, Plasmacluster Ion will not be
released.
• When the operation nishes, the unit will return to the prior
operation mode.
It is able to change the other mode or turn o during
this mode.
NOTE
FAN SPEED
SLEEP
• The unit will operate very quietly with low fan speed.
Plasmacluster Ion Indicator goes o automatically. Even
though the indicator is o, Plasmacluster Ion is released
into air unless Plasmacluster Ion is turned o by .
NOTE
OM_FP-F30A_EN.indd 6 2015/10/14 10:53:05

ENGLISH
E-7
If the , , lamp Lights up for 10 seconds, the setting is completed.
3 sec.
3 sec.
OFF
OFF
Light Control
Plasmacluster Ion ON/OFF
You can set the Plasmacluster Ion Indicator to OFF when the Plasmacluster Ion Indicator is bright.
ON
more than
3 sec.
more than
3 sec.
OFF
•When the unit starts operation, the
Plasmacluster Ion Indicator always
lights.
•In SLEEP mode, Light Control
button doesn’t operate.
NOTE
When Plasmacluster Ion is ON, the Plasmacluster Ion Indicator Light will turn on. (blue)
ON OFF
Auto RESTART
If the unit is unplugged or if there is a power failure, the unit will resume operation with the previous
settings after power is restored.
ON OFF
(with the unit OFF)
more 3 sec.
(with the unit OFF)
more 3 sec.
When Indicator is o,
•To turn OFF Plasmacluster Ion, the
indicator will ash for 3 seconds.
•To turn ON Plasmacluster Ion, the
indicator will light up for 3 seconds.
NOTE
Flashing
Lighting
Lighting Flashing
OM_FP-F30A_EN.indd 7 2015/10/14 10:53:06

E-8
Gently remove dust from the back panel
by using a vacuum cleaner attachment or
similar tool.
BACK PANEL (Pre-lter)
To maintain optimum performance of this air purier, please clean the unit including the lter
periodically.
Be sure to disconnect the power cord from the wall outlet before performing any maintenance.
CARE AND MAINTENANCE
Back Panel
Back Panel
UNIT
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
•Do not use volatile uids
Benzene, paint thinner, polishing powder, etc. , may damage the surface.
•Do not use detergents
Detergent ingredients may damage the unit.
CAUTION
1. Add a small amount of kitchen detergent to
water and soak for about 10 minutes.
2. Rinse o the kitchen detergent with clean
water.
3. Completely dry the lter in a well-ventilated
area.
How to clean stubborn dirtNOTE
Do not apply excessive pressure when
scrubbing the back panel.
CAUTION
Gently remove dust from the HEPA FILTER with a vacuum
cleaner attachment or similar tool.
HEPA FILTER
CAUTION
• Do not WASH in water and DRY in the sun.
• Apply the maintenance only on the side with the tag.
Do not clean the opposite side; otherwise, the lter will be
damaged.
The lter is fragile, be careful not to apply too much force.
Tag
OM_FP-F30A_EN.indd 8 2015/10/14 10:53:06
Indice
Altri manuali Sharp Purificatore d'aria

Sharp
Sharp KC-D60EU-W Manuale utente

Sharp
Sharp FU-551KB Manuale utente

Sharp
Sharp FU-D40A Manuale utente

Sharp
Sharp KC-A60EU Manuale utente

Sharp
Sharp IG-A20EK-W Manuale

Sharp
Sharp KC-D60E Manuale utente

Sharp
Sharp FU-40SE Manuale utente

Sharp
Sharp FP-GM50Y Manuale utente

Sharp
Sharp KCF31RW Manuale utente

Sharp
Sharp IG-BC2A Manuale utente

Sharp
Sharp UA-HG30E Manuale utente

Sharp
Sharp IG-EX20B Manuale utente

Sharp
Sharp FZ-S63MF Manuale utente

Sharp
Sharp FP-J50 Manuale utente

Sharp
Sharp Plasmacluster KC-30TX1 Manuale utente

Sharp
Sharp KC-A50EU Manuale utente

Sharp
Sharp FZ-Y30SFE Guida

Sharp
Sharp FZ-28SEF Manuale utente

Sharp
Sharp UA-HG60E Manuale utente

Sharp
Sharp Plasmacluster KC-860U Manuale utente