Sharp FP-G50J Manuale utente

FP-G50J
R
AIR PURIFIER
OPERATION MANUAL
Free standing type
“Plasmacluster” and “Device of a cluster of grapes” are
trademarks of Sharp Corporation.
*The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm3,
which is measured around the center of a room with
the “high-density plasmacluster 7000” applicable oor
area (at 1.2 m height above the oor) at the medium
wind volume in air purifying mode, when an air purier
using the high-density plasmacluster ion evolving
device is placed close to a wall. This product is
equipped with a device corresponding to this capacity.
OM_FP-G50J_EN.indd 1 2017/01/10 16:47:14

HEPA Filter
Deodorizing Filter
Back Panel
NOTE
The air purier draws in room air from the air intake, passes the air through a Back
Panel, a Deodorizing Filter and a HEPA Filter inside of the unit, then discharges the air
through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small
as 0.3 microns that pass through the lter and also helps absorb odors.
The Deodorizing Filter gradually absorbs odors as they pass through the lter.
Some odors absorbed by the lters may break down over time, resulting in additional
odor. Depending on the usage environment, especially when the product is used in
extreme environments (significantly more severe than normal household use), this
odor may become strong in a shorter period than expected. If the odor persists, the
lters should be replaced.
• The air purier is designed to remove air-suspended dust and odor, but not harmful gases (for ex-
ample, carbon monoxide contained in cigarette smoke). If the source of the odor still exists, the air
purier may not completely remove the odor.
Please read before operating your new Air Purier
OM_FP-G50J_EN.indd 2 2017/01/10 16:47:15

E-1
ENGLISH
Thank you for purchasing the SHARP
Air Purier. Please read this manual carefully.
Before using this product, be sure to read the
section: “Important Safety Instructions.”
After reading this manual, keep it in a
convenient location for future reference.
For your reference, we recommend to keep
this manual in the place where you can read
at any time.
IMPORTANT SAFETY INSTRUCTIONS
..... E-2
PART NAMES...............................................E-4
FILTER INSTALLATION ............................. E-5
OPERATION .................................................E-6
CARE AND MAINTENANCE .....................E-8
TROUBLESHOOTING ..............................E-10
SPECIFICATIONS...................................... E-11
FOR CUSTOMER ASSISTANCE ............E-12
CONTENTS
FEATURES
Unique Combination of Air Treatment
Technologies
Triple Filtration System + Plasmacluster
TRAPS DUST*
Pre-filter traps dust and other large
airborne particles.
DECREASES ODORS
Deodorizing filter absorbs many common
household odors.
REDUCES POLLEN & MOLD*
HEPA filter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the
way nature cleans the environment by
emitting a balance of positive and negative
ions.
*When air is drawn through the lter
system.
Sensor Technology continuously monitors
air quality, and automatically adjusting
operation based on detected air purity.
OM_FP-G50J_EN.indd 1 2017/01/10 16:47:15

E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, in-
cluding the following:
WARNING - To reduce the risk of electrical shock, re or injury to persons:
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the
wall outlet is loosened.
• Periodically remove dust from the power plug.
• Do not insert ngers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or re from short circuit may occur as a result.
• Be careful not to damage the power cord, it may cause electric shock, excess heat or
res.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not
using the unit.
Electrical shock from bad insulation and/or re from short circuit may occur as a result.
•When cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electrical
shock and/or re from a short circuit may result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service
agent, Sharp Approved Service Centre or similarly qualified person in order to
avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue,
incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity con-
ditions, such as a bathroom.
• Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
• Only a Sharp Authorized Service Centre should service this air purier. Contact the near-
est Service Centre for any problems, adjustments, or repairs.
• This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
NOTE - Radio or TV Interference
If this air purier should cause interference to radio or television reception, try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
OM_FP-G50J_EN.indd 2 2017/01/10 16:47:15

E-3
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may
come into contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on the back of the unit when moving it.
• Do not use without the lters inside the unit.
• Do not wash and reuse the HEPA lter and the deodorizing lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
INSTALLATION GUIDELINES
•When using the unit, place it away from equipment utilizing electric waves such as
televisions or radios to avoid electrical interference.
• Avoid use in locations where furniture, fabrics or other items may come in contact
with and restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or drastic
temperature changes. Appropriate conditions are when room temperature is
between 0 – 35 ºC.
• Place on a stable surface with sufcient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack as a result.
•Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper
airow.
The dust collecting performance will be the same even if using the unit 3cm away from
the wall, but place it as far as possible(30cm away recommended) because it may dirty
the wall or oor around.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lter.
OM_FP-G50J_EN.indd 3 2017/01/10 16:47:15

E-4
PART NAMES
19
18
2
1
1Main Unit 10 Handle
2Air Outlet 11 Dust Sensor /
Dust Sensor Filter
3OFF TIMER Button / OFF TIMER indicator Light (green)
LIGHT ON/OFF Button (Press 3 sec.) 12 HEPA Filter
4MODE Button / MODE Indicator Light (green)
Plasmacluster Ion ON/OFF Button(Press 3 sec.)
13 Deodorizing Filter
14 Upper Tabs
5CLEAN ION SHOWER Button /
CLEAN ION SHOWER indicator Light (green) 15 Back Panel (Pre-Filter)
6POWER ON/OFF Button 16 Bottom Tabs
7ODOR sensor 17 Power Cord
8DUST AND ODOR SIGN 18 Plug
9PLASMACLUSTER SIGN 19 Date Label
FRONT
BACK
17
14
15
PLASMACLUSTER SIGN
blue Plasmacluster ON
off Plasmacluster OFF
9
8
Clean
Impure
Red
Orange
Green
3 4 5 6
10
11
12
13
16
DUST AND ODOR SIGN
Indicates the air purity of the room
in 3 levels with color changes.
7
(Shape of plug depends on country.)
OM_FP-G50J_EN.indd 4 2017/01/10 16:47:18

E-5
FILTER INSTALLATION
To maintain the quality of the lter, it is installed in the main unit and packed in plastic
bag. Be sure to remove the lter from the plastic bag before using the unit.
• Do not operate the unit without the lter.
Date Label
Be sure to remove the power plug
from the wall outlet.
1
Remove the Back Panel.
2 Remove the lter from the plas-
tic bag.
3
Place the Filter within the main
unit.
Do not install the lter backwards or the
unit will not operate properly.
Upper Tabs
Pull
HEPA Filter
Deodorizing Filter
Starting date of use
. .
. .
. .. .
. .. .
FZ-F50HFE
HEPA Filter
Deodorizing Filter
FZ-F50DFE
. .. .
. .. .
. .. .
MODEL
MODEL
Push
Push
4 Replace the Back Panel to the
main unit.
5Fill in the usage start date on the
Date Label.
Use the date as a guide for the lter re-
placement schedule.
Bottom Tabs
OM_FP-G50J_EN.indd 5 2017/01/10 16:47:21

E-6
OPERATION
AUTO SLEEP MED MAX
CLEAN AIR
START
• Select the desired fan speed.
• Unless the power cord has been unplugged,
the operation starts in the previous mode it
was operated in.
STOP
FAN SPEED
SLEEP
• The unit will operate very quietly, and the fan speed
is automatically switched depending on the amount of
impurities in the air.
DUST AND ODOR/PLASMACLUSTER SIGN go off
automatically.
Even though the indicator is off, Plasmacluster Ion is
dispersed into air unless Plasmacluster Ion is turned off by
.
NOTE
AUTO
• The fan speed is automatically switched depending on the
amount of impurities in the air. The sensors detect impurities
for efcient air purcation.
Releases high-density Plasmacluster ions and discharges strong air ow for 60 minutes.
CLEAN ION SHOWER
START
• If Plasmacluster Ion is OFF, Plasmacluster Ion will not be
released.
• When the operation nishes, the unit will return to the prior
operation mode.
It is able to change the other mode and during this
mode.
NOTE
OM_FP-G50J_EN.indd 6 2017/01/10 16:47:26

E-7
Light Control
Plasmacluster Ion ON/OFF
You can set the DUST AND ODOR/PLASMACLUSTER SIGN to OFF when their SIGN is bright.
ON
more than 3 sec.
OFF
• When the unit restarts its
operation, Light Control
resumes its setting set before
turning off.
• At Sleep Mode, Light Control
is available.
NOTE
When Plasmacluster Ion is ON, the PLASMACLUSTER SIGN will turn on. (blue)
(In operation)
ON OFF
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY
Set to “Low” if the DUST AND ODOR SIGN is constantly red to reduce sensitivity, and set to “High” if
the DUST AND ODOR SIGN is constantly green to increase sensitivity.
OFF TIMER
Select the length of time you want, with the unit on. The unit automatically stops once the selected
time is reached.
CANCELLATION
• If the power ON/OFF Button is
not pushed within 8 seconds of
adjusting sensor sensitivity, the
setting will be saved automatically.
• The sensor sensitivity setting
will be saved even if the unit is
unplugged.
NOTE
1
2
3
(with the unit OFF)
High
Standard
Low
more than 3 sec.
more than 3 sec. more than 3 sec.
more than 3 sec.
OM_FP-G50J_EN.indd 7 2017/01/10 16:47:34

E-8
CARE AND MAINTENANCE
Gently remove dust from the back panel, using a vacuum
cleaner attachment or similar tool.
BACK PANEL (Pre-lter)
To maintain optimum performance of this air purier, please clean the unit including the lter
periodically.
Be sure to disconnect the power cord from the wall outlet before performing any maintenance.
Back Panel
CAUTION
Back Panel
Do not apply excessive pressure, when scrubbing the back
panel.
NOTE How to clean hard to remove dirt
1. Add a small amount of kitchen detergent to water and soak
for about 10 minutes.
2. Rinse off the kitchen detergent with clean water.
3. Completely dry the lter in a well-ventilated area.
FILTERS
Tag
HEPA Filter
Deodorizing Filter
CAUTION
Gently remove dust from HEPA Filter and Deodorizing Filter with a vacuum
cleaner attachment or similar tool.
Do not WASH in water and DRY in the sun.
The lters are fragile, be careful not to apply too much force.
• HEPA Filter
Apply the maintenance only on the side with the tag.
Do not clean the opposite side; otherwise, the lter will be
damaged.
• Deodorizing Filter
The maintenance can be applied to the both sides.
UNIT
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
•Do not use volatile uids
Benzine, paint thinner, polishing powder, etc., may damage the surface.
•Do not use detergents
Detergent ingredients may damage the unit.
CAUTION
OM_FP-G50J_EN.indd 8 2017/01/10 16:47:37
Indice
Altri manuali Sharp Purificatore d'aria

Sharp
Sharp IG-CL15B Manuale utente

Sharp
Sharp FU-425E Manuale utente

Sharp
Sharp UA-PE30E Manuale utente

Sharp
Sharp FU-P40S Manuale utente

Sharp
Sharp FP-K50UW Manuale utente

Sharp
Sharp KC-F32EU Manuale utente

Sharp
Sharp KC-A60TA Manuale utente

Sharp
Sharp KC-A60J Manuale utente

Sharp
Sharp IG-A10EK-W Manuale

Sharp
Sharp Plasmacluster FP-P40CX Manuale utente

Sharp
Sharp Plasmacluster FP-A28C Manuale utente

Sharp
Sharp IG-A10UR Manuale utente

Sharp
Sharp IG-A20EK-W Manuale

Sharp
Sharp KC-D61R Manuale utente

Sharp
Sharp KC-860EKW Manuale utente

Sharp
Sharp FP-JM40B Manuale utente

Sharp
Sharp FZ-C150DFE Manuale utente

Sharp
Sharp FP-J40E Manuale utente

Sharp
Sharp FU-Z31E Manuale utente

Sharp
Sharp IG-DL1Y Manuale utente