Sharp IG-A10A Manuale utente

中文
Plasmacluster Ion Generator
OPERATION MANUAL
HD 離子簇抗
菌機
使用說明書
Read and keep this manual carefully.
請仔細閱讀並妥善保存這本手冊。
IG-A10A
Plasmacluster and Plasmacluster HD are
trademarks of Sharp Corporation.
ENGLISH
IG-A10A Chi-5.indd 1 2008/11/20 12:31:10

FEATURES
SHARP’s Original Air Disinfecting Technology.
Plasmacluster HD helps to improve the air quality by eliminating of
airborne mold*1, viruses*2, allergens*3,and adhering odor*4.
Release Plasmacluster Ions.
1
Plasmacluster Ions are the
same positive and negative
ions found in nature. The
ions are surrounded by water
molecules, and are released
into the air.
2
Attack Airborne microbes.
The ions form hydroxide
radicals that are highly
oxidizing only when they
adhere to the surfaces of mold
and viruses. They instantly
remove the hydrogen from
the surface proteins, breaking
them down.
3
Return to the air as water.
The hydroxide (OH) radicals
combine with hydrogen (H) to
form water (H2O) which returns
to the air.
Testing and verication Organization.
*1 Ishikawa Health Service Association.
*2 Retroscreen Virology, Ltd, UK.
*3 Hiroshima University.
*4 Japan Spinners Inspecting Foundation.
GLP*5-compliant test facilities have gathered highly
reliable safety data on Sharp's Plasmacluster
technology.
•Skin irritation/corrosion test
•Eye irritation/corrosion test
•
Inhalation toxicity test (lung tissue genetic impact assessment)
Tested by: Mitsubishi Chemical Safety Institute
*5 GLP(Good Laboratory Practice) is a system of
management controls for test facilities and test
procedures designed to ensure the reliability of
chemical safety assessment tests.
Hydroxide (OH) radical
Protein
water (H2O)
Hydrogen(H)
IG-A10A.Eng-5.indd 2 2008/11/20 12:15:11

ENGLISH
ENGLISH
Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please
read this manual carefully before using Plasmacluster Ion Generator.
After reading, keep the manual in a convenient location for future reference.
E-1
Hydroxide (OH) radical
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS ...............E-2
• WARNING ...............................................................E-2
• CAUTIONS CONCERNING OPERATION ......................E-2
• INSTALLATION GUIDELINES......................................E-2
PARTS NAME ........................................................E-3
• FRONT.................................................................................E-3
• BACK ................................................................................... E-3
INSTALLATION POSITION...........................................E-4
OPERATION ...................................................................... E-4
CLEANING AND MAINTENANCE .............................E-5
• MAIN UNIT...........................................................................E-5
• FILTER ................................................................................. E-5
PLASMACLUSTER ION GENERATING UNIT REPLACEMENT
.... E-6
HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT
.... E-7
SPECIFICATIONS............................................................ E-8
TROUBLESHOOTING....................................................E-8
• While IG-A10A can inactivate and eliminate suspended viruses
and other contaminants, it cannot create a completely sterile
environment. SHARP does not guarantee its ability to prevent
microbial infection.
• To enable stable emission of high-density Plasmacluster ions, the
Plasmacluster Ion Generating Unit mounted in IG-A10A will need
to be replaced periodically*.
*Replacement is required approximately every 2 years (17,500 hours) when operated
24 hours a day. IG-A10A will stop operating after about 26 months (19,000 hours) if
the Plasmacluster Ion Generating Unit is not replaced.
IG-A10A.Eng-6.indd 3 2008/11/21 10:41:45

E-2
CAUTIONS CONCERNING OPERATION:
• DO NOT block the air intake and/or air outlet.
• DO NOT use the unit near or on hot objects, such as stoves or heaters or where it may come
into contact with steam.
• Always operate the main unit in an upright position.
• Clean the exterior with a soft cloth only, otherwise the main unit surface may be damaged or
cracked.
• Keep the main unit away from water.
INSTALLATION GUIDELINES:
• Place at least 2m away from equipment utilizing electric waves such as televisions or radios to
avoid electrical interference when using the unit.
• Avoid using in locations where the unit is exposed to condensation or drastic temperature
changes. Appropriate room temperature is between 0-35ºC.
• Avoid locations where grease or oily smoke is generated, otherwise the main unit surface may
crack as a result.
NOTE - Radio or TV Interference:
If this Plasmacluster Ion Generator may cause interference to radio or television reception,
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the distance between the unit and radio/TV receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the following:
WARNING - To reduce the risk of electrical shock, re, or injury :
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• DO NOT use the unit if the power cord or plug is damaged, or the connection to the wall outlet
is loosened.
• Periodically remove dust from the plug.
• DO NOT insert ngers or foreign objects into the air intake or air outlet.
• Always hold the plug and never pull on the cord when removing the power plug.
Electrical shock and/or re from a short circuit may result.
• DO NOT remove the plug when your hands are wet.
• DO NOT use the unit near gas appliances or replaces.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent, a
Sharp authorized Service Center or qualied person in order to avoid a hazard.
• Be cautious when cleaning the unit.
Strong corrosive cleansers may damage the exterior.
• DO NOT use it in the areas where the unit may get wet.
• DO NOT use spray products near the unit.
•
DO NOT use in the rooms, containing oil component, incense, cigarettes’ sparks, and chemical fumes.
• DO NOT operate when using aerosol insecticides or in rooms where there is oily residue, in-
cense, sparks from lit cigarettes, chemical fumes in the air, or in locations where the unit may
get wet, such as a bathroom.
• Only a Sharp Authorized Service Center should service this Plasmacluster Ion Generator.
Contact the nearest Service Center for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
• Children should be supervised to ensure that they do not play with the appliance.
IG-A10A.Eng-5.indd 4 2008/11/20 12:15:11

ENGLISH
E-3
FRONT
BACK
Louvers
Power Cord
Plug
DISPLAY
High (blue)
Low (blue)
Operation
Button
Unit Replacing
Light (red)
PARTS NAME
Use a pointed object, e.g a pen tip, to press
this button after replacing Plasmacluster Ion
Generating Unit.
Do not press it for any other purpose.
(This is to reset the Unit Replacing Light.)
(See E-4)
Top Cover Cap
Screws
Air outlet
Top Cover
Plasmacluster Ion
Generating Unit
(See E-6,7)
Filter (Air Intake)
Filter (Air Intake)
(See E-5)
(See E-6)
Fan Speed
Indicator
IG-A10A.Eng-5.indd 5 2008/11/20 12:15:12

E-4
INSTALLATION POSITION
Place the main unit on a smooth,
stable surface in a room and
insert the plug into an outlet.
LOW
HIGH
'OFF'
OPERATION
DO NOT hold the louvers when carrying the unit.
Leave at least 15cm of clearance behind the Unit.
Press the operation button to directly turn on the power and
select the preferred mode.
UPSIDE More than 1m
DO NOT USE the below items near the unit.
TV
RADIO
FURNITURE
ATOMIC
CLOCK
silicone-containing products*
SPRAY WAX
PESTICIDE
*Hair care products, cosmetic products,
water proof sprays, polish glass cleaner,
wipe and wax.
Release high-density
Plasmacluster ions quietly.
Increase the volume of
Plasmacluster ions to increase
the purifying capacity.
Power 'OFF'.
Installation Guidance.
BACKSIDE
More than 15cm
LEFT/RIGHT SIDE
More than 20cm
Louvers
The air comes from direction, which is stamped on the
louvers.
•When releasing ions to the entire room, put each louver in
an opposite direction.
•When releasing ions to the point to deodorize the adhering
odor on clothes, put both louvers in the same direction.
IG-A10A.Eng-5.indd 6 2008/11/20 12:15:14

ENGLISH
E-5
CLEANING AND MAINTENANCE
WARNING:
When cleaning the unit, be sure to rst unplug the power cord,
and never handle the plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
Main Unit
Every month or more often if necessary
Wipe with a dry soft cloth.
<For Stubborn Dirt>rt>
Use water and a mild detergent. And
then, wipe with a wet cloth.
Make sure to dry out the main unit.
Filter
Every 2 weeks or more often if necessary
Filter
Filter
Gently remove dust from the
filters by using a vacuum
cleaner.
<For Stubborn Dirt>
Detach the filter and remove dust with
using a vacuum cleaner.
*The lter is not disposable item, often clean it.
IG-A10A.Eng-5.indd 7 2008/11/20 12:15:14

E-6
PLASMACLUSTER ION GENERATING UNIT REPLACEMEN
T
In order to release Plasmacluster Ion stably, periodical Plasmacluster
Ion Generating Unit replacement is necessary. The Unit Replacing
Light will be ON as a reminder for replacement.
Elapsed Time
Replacement of Plasmacluster Ion Generating Unit
Display Message
*Usage environment affects the lifetime of the Plasmacluster Ion Generator.
The Plasmacluster Ion Generator may stop working before estimated lifetime.
In this case, press Operation button again and restart.
If this does not help, replace with a new Plasmacluster Ion Generating Unit.
Plasmacluster Ion Generating Unit
Model Number IZ-CA10E
Beginning to use
approx. 2 years
(approx. 17,500hours)
approx. 2 years and
2 months
(approx.19,000hours)
Plasmacluster Ions
are not released.
lighting
(blue)
lighting
(blue)
ashing(red) Suggest replacing
ashing faster
(red)
• Stop working
• Replace the
Plasmacluster
Ion Generating
Unit
All light are
ashing Error*
<For Disposal>
Please dispose the used Plasmacluster
Ion Generating Unit according to any local
laws and regulations.
-materials-
• Case : Polystyrene
•
Unit : Polystyrene Terephthalate, Electric
parts
IG-A10A.Eng-5.indd 8 2008/11/20 12:15:15

ENGLISH
E-7
PLASMACLUSTER ION GENERATING UNIT REPLACEMEN
T
HOW TO REPLACE THE PLASMACLUSTER
ION GENERATING UNIT
*When replacing the Plasmacluster Ion Generating Unit, be sure to turn off the
main unit, unplug the power cord, and never handle the plug with wet hands.
1
Remove the
LOUVERS.
Remove the TOP
COVER CAP.
2
Turn the 2 SCREWS
SCREWS
4
5
Lift up the TOP
COVER.
Replace the
Plasmacluster Ion
Generating Unit.
Suggest replacing
3
*See the manual of Plasmacluster Ion
Generating Unit for replacement.
IG-A10A.Eng-6.indd 9 2008/11/20 16:48:41

E-8
SPECIFICATIONS
TROUBLESHOOTING
*The target oor surface area for which an emitted airborne ion density of about 25,000 ions/cm3can
be measured at a point near the center of the room (at a height of about 1.2 m from the oor), during
operation at the HIGH mode when the main unit is placed near a wall.
• The number of ions will vary according to the room conditions and the main unit operation mode.
Model
Power supply
Power consumption (W)
Operating noise level (dBA)
Airow volume (m3/hour)
Applicable oor surface area (m2)*
Power cord (m)
Outer dimensions (mm)
Weight (kg)
220-240V, 50/60Hz
(High)
14.0
(High) 44
(High) 102
10
1.8
140 160 345 (W D H)
2.5
IG-A10A
(Low) 6.5
(Low) 34
(Low) 72
Problem WHAT TO DO
The Plasmacluster Ion Generator
does not work.
Make sure to put in the plug.
Approx. 2 years and 2 months (approx. 19,000
hours) has been passed.
Replace with a new Plasmacluster Ion Generating
Unit. See page E-6,7.
Plasmacluster Ions are not released.
Press the Operation button and restart.
Failure
Unplug and contact the store you purchased or
Sharp Service Center.
The discharged air has odor. The Plasmacluster Ion Generator releases a
small trace of ozone which may produce odor.
This is not harmful to health.
A clicking or ticking sound comes
from the unit while operating the
Plasmacluster Ion Generator.
Loudness can be changed depending on a room
humidity, but the effectiveness is the same.
Relocate the Plasmacluster Ion Generator if
necessary.
ashing faster
(red)
ashing (red)
ashing (blue)
ashing (blue)
ashing (blue)
Before calling for service, please review the TROUBLESHOOTING chart below,since the problem may
not be Plasmacluster Ion Generator malfunctions.
If all lights keep ashing, replace with new
Plasmacluster Ion Generating Unit. See page E-6,7.
• Dust may block the lter, clean the lter.
IG-A10A.Eng-5.indd 10 2008/11/20 12:15:17