Model number SDO-10D SDO-16D SDO-20D
Power supply 220-240 V ~ 50 Hz 220-240 V ~ 50 Hz 220-240 V ~ 50 Hz
Power consumtion 175 W 400 W 390 W
Dehumidifying 10 L/day (30°C, 16 L/day (30°C, 20 L/day (30°C,
capacity RH 80%) RH 80%) RH 80%)
Water tank 2 L 2 L 2 L
3
3
3
4
Notes On Refrigerant R290 6
8
8
9
11
12
12

EN
SAFETY INSTRUCTIONS
4
•Please read the operating instructions carefully
before using your dehumidifier for the first time and
keep it on a safe floor.
•Never immerse the appliance in water or other
liquids.
•Place the unit on a stable flat surface to avoid loud
noises and vibrations.
•Never operate the appliance if a cable or
connector has been damaged, after appliance
malfunction or if the appliance was dropped or
otherwise damaged.
•The appliance may only be repaired by qualified
personal, improper repair work can be a source of
considerable danger for the users.
•Pull out the power plug before transporting it and /
or before cleaning.
•Operate the appliance only at the voltage specified
on the rating label.
•The device may not be connected to a power strip
with other household appliances.
•Use the appliance only in the household, and only
for the purpose it was developed for.
•Do not operate this unit near heating appliances
and flammable or dangerous objects.
•If the dehumidifier is operated in a room with gas
driven devices, so the room must be aired regularly
and often.

•Please use the function of the internal drying, if the
device is not used for a long time. This will prevent
formation of mildew and unpleasant smell inside the
unit.
•Do not place heavy objects on the appliance.
•Do not hang curtains or wet clothes in front of the air
outlet, this will overload the device.
•The drainage hose may not be installed outdoors at
low temperatures.
•To prevent spillage, empty the water tank before
relocating the appliance.
•Do not tip the appliance to any side as escaping water
could damage the appliance.
•If the supply cord is damaged, it must be replaced by
a qualified person to avoid a hazard.
•If you smell the smoke during start-up or if you can see
the smoke, immediately disconnect the power plug out
and contact your dealer.
•The unit should be installed with a minimum distance of
20 cm from the wall or other obstacles.
•This appliance can be used by children aged from 8
years and above and persons with reduced physical,
sensory and mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved. Cleaning
and user maintenance shall not be made by children
without supervision.
5

NOTES ON REFRIGERANT R290
Warnings
•The air conditioning system must be kept and
transported upright. Otherwise, irreparable compressor
damage may occur. Leave the unit for at least 24 hours
before putting it into operation.
•Switch off the device and disconnect it from the power
supply before cleaning.
•Make sure that the product creates a steady stream of
air. Ensure the air inlets and outlets are not blocked.
•To prevent leaks, operate this unit on a horizontal
surface.
•Any person performing work on a refrigerant circuit
should have a current
certifi cate from an industry-accredited assessment
body. This ensures competence for the safe handling of
refrigerants according to an industry-recognised
assessment specifi cation.
•If the device stops working, dispose of it properly.
•Store the device in a well-ventilated place when not in
use.
•Store the device so that it is not damaged.
•Repairs may only be carried out by the manufacturer or
an authorised specialist company.
•The cables connected to the device may contain
potential ignition sources.
•Do not damage any components of the refrigerant
circuit. Escaping refrigerant may not be noticed
because it is odourless.
EN
6

Information for rooms with refrigerant pipes
•Limit the piping to a minimum.
•Be careful not to damage the piping.
•Appliances with fl ammable refrigerants may only be
installed in a well-ventilated room.
•Comply with national gas regulations.
•All mechanical connections must be freely accessible
for maintenance purposes.
CAUTION
Risk of fi re! This device contains the
flammable refrigerant R290. If the
refrigerant escapes and is exposed to an
external ignition source, there is a risk of fi re.
•Maintenance and repairs must be carried out under
the supervision of specialists in the use of fl ammable
refrigerants.
7

EN
8

High
Low
Auto
Cloth-dry
Waterfull
In standby state press the Power button to start, and during operation
of the dehumidifier press the Power button to shut down. For initial
startup the default is low wind, the display show the environment
temperature and the default set humidity is RH50%. If the dehumidifier
is not energized for the first time, after startup the state is kept the
same as that before shutdown. The LED is closed, only power light is
illuminated when standby.
In boot state or regular boot, press this button to chose autumatic
dehumidification or cloth dry function , each function have 2 second
confirmation delay time.
In boot state, press this button, the LED light and blink. In blink time,
press button to set the time of timing. press
buttom to add/reduce one hour . Keep pressing the button
to add/reduce time as well. The maximum is 24 hour, the minimum is
1 hour. LED blink 5 time to confirm the timing set. Press the timer
button again to reset the timing time in timing status.
Press button( each press for 5%RH to select humidity
from 30-80%RH only in automatic dehumidification.
Press this button to choose fan speed, high-low-high, only valid in
automatic dehumidification. Keep pressing fan speed button for 5s
to start inside dry.
9

Important Notes
• Do not use the machine when the environmental temperature is over 35°C or below 5°C.
• Pour the water when the water tank is full and the indicator will become red. Then
put the water tank to the original place so that the machine can work again.
• Restart the machine after at least 3 minutes when it stopped in order to avoid to
destroy the compressor.
Water drainage manually
1 The compressor and motor will stop
when the water tank is full and the
red indicator light will be on.
2 Take out the water tank and then
pour the water off.
3 Put the water tank to the original place
and restart the machine (three minutes
self-protect for compressor after stop).
Water drainage continuously
1 Cut off the power.
2 Cut the three seal of continuous drainage hose.
3 Connect the water pipe of inner diaineter (thickness = 9mm*2mm) to the drain
hose)
4 Route the other end of the hose into a drain that is deeper than the water outlet.
EN