Troubleshooting
The Quick Glove has a user friendly design but needs to be handled properly to perform as intended.
Following explanations have been made using the Quick Clamp attachment platform. Some of the
problems explained can occur, as well as be solved in the same ways, when using the Quick Cuff
as an attachment platform.
• The Release Ring of the Quick Glove assembly is threaded against its stop position on the
leading edge of the Connecting Ring.
• The Release Ring is in contact with the flange of the Quick Clamp.
• The Spanner Ring is positioned so that the Quick Glove assembly can use full travel length into
the Quick Clamp compartment.
This scenario prevents the Quick Glove assembly from reaching full travel length into the Quick Clamp
attachment platform. This will most likely cause instability that can lead to leakage and in worst
case cause the Quick Glove to be fully released and fall of.
This scenario will most likely cause instability that can lead to leakage and in worst case cause the
Quick Glove to be fully released and fall of.
This scenario will most likely cause instability that can lead to leakage and in worst case cause
the Quick Glove to be fully released and fall off.
In all cases when you notice that something is wrong, we recommend you to detach the Quick Glove
assembly from the docking ring. Solve the issue that caused the problem and attach the system again.
1
1
2
3
4
2 3 4
Illustration no.1 is correct! The other examples are incorrect.
Quick Glove when attached
properly into the Quick Clamp
attachment platform.
The Quick Glove assembly has
been guided in wrong and
ended up in a tilted position.
The Release Ring of the
Quick Glove assembly is
positioned incorrectly.
The Spanner Ring has
been pressed too far
into the docking ring.
www.sitech.sewww.sitech.se
Maintenance and Storage
• Ensure that all components are clean and properly lubricated before diving the system.
• Disassemble and rinse all parts thoroughly in fresh water to remove sand and dirt.
• Make sure that the O-ring and the groove in the Connecting Ring is clean before re-fitting
the O-Ring. Note: O-rings must be changed if damaged or contaminated by silicone lubricants.
• Disassemble the system when stored for longer periods.
Spare Parts
Item no.
Quick Glove
60231
60232
80185
61357-20
60211
60212
60233
Item
Connecting Ring
Release Ring
O-Ring
Paraffin Wax
Spanner Ring, black: for thick fabrics
Spanner Ring, blue: for medium fabrics
Pressure Equalization Tube
Item
Wrist Ring
Stiff Ring
Docking Ring
Spanner Ring, yellow: for thick fabrics
Spanner Ring, green: for thin fabrics
Spanner Ring, blue: for medium fabrics
Item no.
Quick Cuff
60420
60200
Quick Clamp
60931
60214
60219
60212
Seals
61150
61130
61100
61090
61025
61026
Latex Seal, X-Small (wrist circumference 12,5-14 cm / 5,0-5,5”)
Latex Seal, Small (wrist circumference 13,5-16 cm / 5,4-6,4”)
Latex Seal, Medium (wrist circumference 15,5-18 cm / 6,2-7,4”)
Latex Seal, Large (wrist circumference 18-21 cm / 7,2-8,4”)
Silicone Seal, Standard (wrist circumference 13,2-17 cm / 5,2-6,7”)
Silicone Seal, Small (wrist circumference 10,6-15 cm / 4,2-5,9”)