Sierra TV-10 Manuale utente

sierradentalequipment@outlook.com www.Dentalvacuums.com
TV-10 Dry Vacuum System
2022 USER MANUAL/Installation Instructions
1953 W. Gulf To Lake Hwy, Lecanto, FL 34461
Phone: 352-527-1975 FAX: 352-513-4801

TABLE OF CONTENTS
Cover
Congratulations
Customer support
Warranty Policy
Safety
Sub Assemblies
What’s Included
Specifications
-Site requirements
-Product Specifications
-Tank Specifications
-Chassis Specifications
System Layout
Installation
Operation
Maintenance
Troubleshooting
Accessories
1
2
3
4
5
6
7
8
8
9
10
11
12
13
17
18
19
20
On the Purchase of your TRU-VAC dry vacuum system. This state-of-the-art dry vacuum is a
very powerful, high volume, efficient system. 230-volt motor provides the HP necessary to
handle high demands while maintaining multiple operatories. Equipped with a Vortex Action
Separator(VAS) Tank, your TRU-VAC dry vacuum system will ensure efficiency and reliability.
We are certain you will love your new product!
If you are not satisfied 100% with this products please reach out and let us know,
we are successful because of your FEEDBACK!
352-527-1975
Email: sierradentalequip[email protected]om
2
Congratulations!

CUSTOMER SUPPORT
“We are happy to help you with any questions or
concerns you may have about your equipment”
Contact Us at 352-527-1975.
We’re here to help!
Sierra Dental Equipment Inc.
1953 W. Gulf to Lake Hwy
Lecanto, FL 34461
DentalVacuums.com
Look for us… on social media!
3

WARRANTY POLICY
Sierra Dental Equipment Limited Warranty
Warranty for the TRU-VAC Dry Vacuum System is limited to the original purchaser
of the unit. Sierra Dental Equipment is only obligated under this warranty to the
repair or replacement of defective parts or materials. The defect(s) must be
reported to Sierra Dental Equipment within the valid warranty period.
Sierra Dental Equipment will examine the product to determine if the parts are
defective. Equipment that has been abused, neglected, or damaged by being
improperly installed/maintained are not covered by this warranty. We are not
responsible for work performed on the unit by any unauthorized service agents.
Warranty Period
Warranty is valid only with the return of the warranty card within 30 days of
purchase for a period of 10 years.
Warranty Service and Return Policy
To obtain warranty service, product must be returned to Sierra Dental Equipment
for examination at the purchaser’s expense. All returns must be authorized, and a
return material authorization (RMA#) number must be obtained from Sierra Dental
Equipment. Returned units must be properly packaged for shipping. We are not
responsible for shipping damages or shipping charges. Sierra Dental Equipment
will, at their discretion, repair or replace defective parts.**PLEASE NOTE** there is
a 25% re-stocking fee on all returns.
4

SAFETY
WARNING
To prevent fire or electrical shock, do
not expose this unit to rain or
moisture, excessive heat or improper ventilation.
ATTENTION USERS
Alerts users of important operating
and maintenance instructions. Read
carefully to avoid any problems
Warns users of a potentially hot
surface, and a danger of burns
Warns users that uninsulated voltage
is present and can cause electric
shock
5
Use of the TRU-VAC not in compliance with the
instructions specified in this manual may result in
permanent failure / voided warranty of the unit.

SUB ASSEMBLIES
Low Voltage Control Box
Vortex Action
Separator Tank
Motor Assembly
6

WHAT’S INCLUDED
7
a) X1 90 Degree Elbow…………………….………………..….......................................……..(1 ½” mpt x 1 ½” fpt)
b) X1 90 Degree Elbow………………………………..………………..................….…...(1 ½” male slip x 1 ½” fpt )
c) X2 Black Nipple..……….....……………….….. ….......................................................(1 ½” mpt x 1 ½” Barbed)
d) X2 Stainless Steel Hose Clamps………..…….……..……………………......………….....….…..(1 13/16” -2 ¾”)
e) X1 Vacuum Flex Hose………….……………………………..…………....…..…..…………(1 ½” dia. x 5’ Length)
f) X1 Low Voltage Controller…….…………………...…….……………….....…...…….(24 Volt, Remote Capability)
g) X1 VAS Collection Tank……………..………....…………......…….....(12 Gallon, 1 ½” Female Slip connections)
h) X1 Motor Assembly….............….......................................……(1.75 HP, 1 ½” fpt inlet. 2" fpt Outlet “Exhaust”)
i) X1 Vacuum Relief Valve/Tee........................................................................(1 ½" Male Slip x 1 ½" Female Slip)
j) X1 Filter.......................................................................................................................(1 ½" fpt x 1 ½" male slip)
k) X1 TV-10………………………...…..……………………………………......….……………….…….USER MANUAL
l) X1 Warranty Card…………….….………………………………….….....……(Fill Out And Return within 30 days)
k.
l.
a.
b. c.
d.
e.
f.
g.
h.
c.
d.
i.
j.
1 ¼" fpt x 2" fpt
galv. bushing
included for
exhaust.

SPECIFICATIONS
Description Specification
(TV-10)
Circuit breaker rating 15 Amp
(230 Volts)
Minimum
wire size 14 Gauge
Vacuum piping 2” trunk -1 ½’ branch
(PVC)
Minimum exhaust vent pipe
2” High temperature flex
hose, 2" SCH. 80 Gray PVC,
2" galvanized, 2" copper,
3"
CPVC.
(DO NOT USE 90 DEGREE
ELBOWS)
(Over 50 feet requires 3-4")
Minimum drain line 1 ½” flex pipe
1 ½” Sch. 40 PVC
SITE REQUIREMENTS
8

SPECIFICATIONS
PRODUCT SPECIFICATIONS
Description Specification
(TV-10)
Voltage 230 V AC
Operating load 8.3 Amps
Start-up load 14 Amps
Frequency 50 –60 Hz
Low voltage remote 24 V AC
Max operators 5 users (5 HVE) or (10 SE)
Tank capacity 12 Gallons
Air flow 62 cfm
Ambient temp 41°-104°F
Max operating temp 214°F
Decibels 61 decibels
Thermal Safety Switch YES
*DO NOT store flammable liquids & mixtures
near this dry vacuum system 9

SPECIFICATIONS
TANK SPECIFICATIONS
TANK
Weight
Length
Width Height Capacity
V.A.S.
43 lbs.
15” 17” 40”
12 Gal.
10
17"
15"
40"
Indice