SIGNIFY LUMEC TULS Manuale utente

Signify Classified - Internal
www.lumec.compage6/10/2019 1
TULS/TULM/TULL
IMPORTANT: FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR
ENTIRETY PRIOR TO INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE. If you do not understand these warnings and instructions, or if additional
S/A INSTRUCTION SHEET FOR MOUNTING SWIVEL TUL
SW - 442294907461
•Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all federal, state and local
laws, regulations and electrical codes. This professional should be familiar with the construction and operation of this product and any hazards
involved. If not qualified, do not attempt installation, service or maintenance.
•To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please read
all warnings and instructions included with the luminaire, on the luminaire’s packaging and affixed to the luminaire itself.
•Maintenance of the luminaires should be performed by person(s) familiar with the luminaire’s construction and operation and any hazards involved.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
•Disconnect or turn off power before attempting any installation, service or
maintenance.
•Verify that supply voltage is correct by referencing the luminaire label
information.
•Make all electrical and ground connections in accordance with the National
Electrical Code (NEC) and any other applicable laws, regulations or codes.
•All wiring connections should be capped with UL-approved wire connectors.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
•Wear gloves and safety glasses at all times when removing luminaire
from carton, installing, servicing or performing maintenance.
•▪Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF PRODUCT DAMAGE
• Never connect luminaires and/or components under load with supply voltage turned on.
• Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
• Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insulation, foam or other material that will
prevent convection or conduction cooling.
• Do not exceed luminaire maximum ambient temperature.
• Do not modify the luminaire.
• Only use luminaire in its intended application and location.
• Led products are polarity sensitive. Ensure proper polarity before installation.
• Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.
• Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.
• Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and contact
Signify.
• Always read the luminaires complete installation instructions prior to installation for any additional luminaire specific warnings.
• In the case of HID or Fluorescent luminaires, regular re-lamping is required to keep luminaire operating within safe limits
• Do not install damaged product. Handling and installing damaged products can potentially increase the risks mentioned In case of damage and/or missing parts
upon arrival of the luminaire.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation,
operation or maintenance.
• Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to follow
any of these Instructions could void luminaires warranties.
Luminaire Maintenance
• Regular luminaire maintenance programs are recommended.
• It is recommended to clean the outside of the luminaire and the refractor/lens.
• Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user.
• If clean water is not sufficient for cleaning, use a neutral, synthetic, not-scratching and not-abrasive cleaning substance.
• Never use alkaline and/or acetous cleaning substances.
• Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water.
• Signify recommends using a cleaning solution that has a PH between 5 and 8.
• Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.
WARNING
RISK OF FIRE OR PERSONAL INJURY
•Keep combustible materials away from LED/lamp & lens
•▪Do not operate in close proximity to persons, combustible materials
or substances affected by heat or drying.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
•Allow Led/lamp & lens to cool before handling.
•▪Do not touch enclosure or light source
•▪Do not exceed maximum wattage marked on luminaire label.
•▪ Follow all manufacturer’s warnings, recommendations, instructions
and restrictions for driver type, burning position, mounting locations
and replacement.

Signify Classified - Internal
page6/10/2019 2
Installation Instructions - 442294907461
Instructions for attaching luminaire to surface
TULS/TULM/TULL
www.brandwebaddress.com
INSTRUCTIONS
1. After the luminaire is installed, the vertical angle of the
luminaire can be adjusted up or down.
2. Unscrew screws (2) on door or open Latches (2) to access
to terminal block and electrical components.
3. Install the ½’’ Liquid Tight Cordgrip (in hole ready to
receive ½’’) with sealing washer, lock nut and power cord
(by others). Torque as supplier recommendation.
4. Connect the service leads to the terminal block. Tight the
set screws between 20 and 25 lbs.in
5. To adjust the angle, loosen the (2) ½-13’’ studs or bolts (by
others) located in the Swivel. (Do not remove stud or
bolts). Loosen only enough to allow rotation.
6. For luminaires with Photo Control, the aiming angle must
be restricted to +/- 45° from horizontal aim.
7. Rotate the luminaire to the desired position and retighten
the bolts loosened in step 4 to approx. 45 ft.-lbs.
NOTE:
Install luminaire as per traffic direction label
Model
B
TULS
19’’
TULM
19’’
TULL
26 ¾’’
Mounting Holes Patterns
3 poles
Terminal Block
2-14 AWG
B
0°
45°
-45°
CAUTION Prevent over torque
damage
Do not over torque nuts and bolts
NOTE: Angle adjustment can be made before
luminaire installation.
Adjustment Bolts
Suggested electrical connection
with Liquid Tight Cordgrip IP66
rated.
Screws
Latches
Hole for .875” Connectors
45 ft.-lbs
20 to 25 lbs.in