Simrad NSO evo3S MPU Manuale utente

ENGLISH
NSO evo3S MPU
Installation Manual
www.simrad-yachting.com


Preface
Disclaimer
As Navico is continuously improving this product, we retain the right to make changes to the
product at any time which may not be reflected in this version of the manual. Please contact
your nearest distributor if you require any further assistance.
It is the owner’s sole responsibility to install and use the equipment in a manner that will not
cause accidents, personal injury or property damage. The user of this product is solely
responsible for observing maritime safety practices.
NAVICO HOLDING AS AND ITS SUBSIDIARIES, BRANCHES AND AFFILIATES DISCLAIM ALL
LIABILITY FOR ANY USE OF THIS PRODUCT IN A WAY THAT MAY CAUSE ACCIDENTS, DAMAGE
OR THAT MAY VIOLATE THE LAW.
This manual represents the product as at the time of printing. Navico Holding AS and its
subsidiaries, branches and affiliates reserve the right to make changes to specifications
without notice.
Governing language
This statement, any instruction manuals, user guides and other information relating to the
product (Documentation) may be translated to, or has been translated from, another
language (Translation). In the event of any conflict between any Translation of the
Documentation, the English language version of the Documentation will be the official
version of the Documentation.
Copyright
Copyright © 2020 Navico Holding AS.
Warranty
The warranty card is supplied as a separate document. In case of any queries, refer to the
brand website of your unit or system:
www.simrad-yachting.com
Compliance statements
Europe
Navico declare under our sole responsibility that the product conforms with the
requirements of:
•CE under RED 2014/53/EU
The relevant declaration of conformity is available in the product's section at the following
website:
•www.simrad-yachting.com
United States of America
Warning: The user is cautioned that any changes or modifications not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
ISED Canada
This device complies with ISED (Innovation, Science and Economic Development) Canada’s
license-exempt RSSs. Operation is subject to the following two conditions: (1) This device
may not cause interference; and (2) This device must accept any interference, including
interference that may cause undesired operation of the device.
La traduction française de ce document est disponible sur le site Web du produit.
Preface | NSO evo3S MPU Installation Manual 3

Australia and New Zealand
Navico declare under our sole responsibility that the product conforms with the
requirements of:
•level 2 devices of the Radiocommunications (Electromagnetic Compatibility) standard
2017
Internet usage
Some features in this product use an internet connection to perform data downloads and
uploads.
Internet usage via a connected mobile/cell phone internet connection or a pay-per-MB type
internet connection may require large data usage. Your service provider may charge you
based on the amount of data you transfer. If you are unsure, contact your service provider to
confirm rates and restrictions.
Trademarks
Navico®is a registered trademark of Navico Holding AS.
Simrad®is used by license from Kongsberg.
HDMI®and HDMI™, the HDMI Logo, and High-Definition Multimedia Interface are trademarks
or registered trademarks of HDMI Licensing LLC in the United States and other countries.
NMEA®and NMEA 2000®are registered trademarks of the National Marine Electronics
Association.
SD™and microSD™are trademarks or registered trademarks of SD-3C, LLC in the United
States, other countries or both.
Navico product references
This manual refers to the following Navico products:
•Broadband Radar™ (Broadband Radar)
•Broadband 3G™ (Broadband 3G Radar)
•Broadband 4G™ (Broadband 4G Radar)
•Halo™ Pulse Compression Radar (Halo Radar)
About this manual
Images used in this manual might not exactly match the screen on your unit.
Important text conventions
Important text that requires special attention from the reader is emphasized as follows:
ÚNote: Used to draw the reader’s attention to a comment or some important information.
Warning: Used when it is necessary to warn personnel that they should
proceed carefully to prevent risk of injury and/or damage to equipment/
personnel.
Intended audience
This manual is written for system installers.
The manual assumes that the reader has basic knowledge about this type of equipment with
regards to:
•installation work to be carried out
•nautical terminology and practices
4Preface | NSO evo3S MPU Installation Manual

Translated manuals
Available translated versions of this manual can be found on the following website:
•www.simrad-yachting.com
Preface | NSO evo3S MPU Installation Manual 5

Contents
7Introduction
7System overview
7 Operating the system
8 Parts included
9 Connectors
9 Card reader
10 Installation
10 General mounting guidelines
11 Wall mounting
12 Wiring
12 Access to connectors
12 Wiring guidelines
12 Control devices
12 Monitors
13 Power
15 NMEA 2000
16 Serial port
18 Ethernet
19 USB port
19 Video in
20 HDMI out
21 System setup
21 First time startup
21 Software setup sequence
21 The settings dialog
21 System settings
23 Alarms
23 Radar installation
26 Echosounder settings
29 Autopilot settings
30 Fuel settings
32 Wireless settings
32 Network settings
36 3rd party support
36 CZone
37 Naviop
37 Mercury
37 Suzuki Marine
37 Yamaha
37 Evinrude
37 Power-Pole
37 FLIR camera setup
38 Dimensional drawings
38 NSO-evo3S MPU
39 Technical specifications
39 NSO evo3S MPU
40 Supported data
40 NMEA 2000 compliant PGN List
43 NMEA 0183 supported sentences
6Contents | NSO evo3S MPU Installation Manual

Introduction
System overview
The basic system consists of the processor and one or two monitors.
The system can be configured and installed in various configurations:
•One processor with one monitor (A)
•One processor with two independent monitors (B)
•A complex network where additional networked processors are connected to
independent monitors throughout the boat (C)
Operating the system
The system supports single and dual touch-screen operation when compatible touch
monitors are connected.
If a compatible remote controller is available on the network, this can control multiple
processors and monitors, including power control. A separate manual is delivered with the
remote controller units.
You can also use a keyboard and mouse/trackball to control the system. Once these devices
are connected to the USB ports on a processor, they can be used to control the monitors
connected to the same processor.
The active controller is indicated with an icon in the status bar.
1
Introduction | NSO evo3S MPU Installation Manual 7

Parts included
F
ABC
D
E
G
H
I
J
A
B
C
NSO evo3S Marine Processor Unit (MPU)
MPU Power cable, 2 m (6.5')
Micro-C power cable, 1.3 m (4.3')
DMicro-C drop cable, male-female plugs, 1.8 m (6')
EMicro-C T-connectors (x3)
FMicro-C terminators, 120 ohm, (male and female)
GNMEA 0183 serial cable, 8 wires, 2 m (6.5')
HEthernet adaptor, 5 pin female to RJ45 male
IInstallation kit:
•Cable retainers (x2)
•Cable ties (x20)
•Pan head screws, 3.5 x 19, A4 DIN7981B (x8)
JDocumentation pack
8Introduction | NSO evo3S MPU Installation Manual

Connectors
NETWORK 1
NETWORK 3
USB 1
VIDEO 1 IN
HDMI 1 OUT
HDMI 2 OUT
SD CARD
NMEA2000
SERIAL 1 SERIAL 2
POWER
45W MAX
VIDEO 2 IN
USB 2
NETWORK 2
PoE 15W
COMBINED
A B C D E F
IH
G
ANetwork 1 and Network 2 ports (Ethernet with PoE)
BNetwork 3 (Ethernet)
CVideo 1 IN and Video 2 IN
DHDMI 1 OUT and HDMI 2 OUT
ENMEA 2000
FSerial 1 and Serial 2
GPower
HUSB 1 and USB 2
ISD card reader
Card reader
A memory card can be used for:
•Chart data
•Software updates
•Transfer of user data
•Logging user data
•System backup
ÚNote: Do not download, transfer or copy files to a chart card. Doing so can damage chart
information on the chart card.
Introduction | NSO evo3S MPU Installation Manual 9

Installation
General mounting guidelines
Warning: Do not install the unit in a hazardous/flammable atmosphere.
ÚNote: Choose a mounting location that will not expose the unit to conditions that
exceed the technical specifications.
Mounting location
This product generates heat which must be considered when choosing the mounting
location.
It is recommended that the unit is installed in a location on the vessel with adequate airflow
and away from areas heated by the environment or other equipment.
Ensure that the selected area allows for:
•Cable routing, cable connection and cable support.
•Connection and use of portable storage devices.
•Viewing any LED indicators.
•Easy access to serviceable parts.
Do also consider:
•The free space around the unit to avoid overheating.
•The mounting surface’s structure and strength, with regard to the weight of the
equipment.
•Any mounting surface vibration that might damage the equipment.
•Hidden electrical wires that might be damaged when drilling holes.
Ventilation
Inadequate ventilation and subsequent overheating of the unit may cause reduced
performance and reduced service life.
Ensure that cables do not obstruct the airflow and that the ventilation holes are not blocked.
Examples of enclosure ventilation options, in order of preference, are:
•Positive pressure air from the vessel's air conditioning system.
•Positive pressure air from local cooling fans (fan required at input, fan optional at outlet).
•Passive airflow from air vents.
Enclosure recommendations
AAir inlet
BAir outlet
2
10 Installation | NSO evo3S MPU Installation Manual