Sinapsi SIN.RPT868XT Manuale utente

S I N A P S I S . r . l .
V i a d e l l e Q u e r c e 1 1 / 1 3
0 6 0 8 3 B a s t i a U m b r a ( P G ) I t a l y
T . + 3 9 0 7 5 8 0 1 1 6 0 4 F . + 3 9 0 7 5 8 0 1 4 6 0 2
w w w . s i n a p s i t e c h . i t |i n f o @ s i n a p s i t e c h . i t
SIN.EQRPT868XT
868 MHz W. M-Bus
sinapsitech℗repeater
User Guide
Rev 1.6
This manual refers to the 1.23 Firmware
version

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 2
TABLE OF CONTENTS
1. INTRODUCTION............................................................................................................................................... 3
1.1 Purpose of the document ..................................................................................................................... 3
1.2 Content of the package ......................................................................................................................... 3
2. SIN.EQRPT868XT TECHNICAL SPECIFICATIONS .......................................................................................... 4
3. ASPECT OF THE SIN.EQRPT868XT ................................................................................................................. 5
3.1 Description of the SIN.EQRPT868XT .................................................................................................... 5
3.2 SIN.EQRPT868XT device......................................................................................................................... 6
4. REPEATER CONFIGURATION THROUGH KEYS FUNCTIONS....................................................................... 7
4.1 Change ID MESH..................................................................................................................................... 7
4.2 Activate SND_IR mode (Installation Mode) ......................................................................................... 8
4.3 Accept mode activation ALL - SIN.EQRPT868XT ................................................................................. 9
4.4 SIN.EQRPT868XT –S, T, C+T, S & C+T Mode of operation modification........................................ 10
4.5 Restore factory settings....................................................................................................................... 11
5. WALL MOUNTING AND PASSING OF CABLES ........................................................................................... 12
6. USB CONNECTION TO THE PC, CONNECTION VIA RADIO TO THE SIN.EQRTU1T AND POSITIONING
13
7. CONFIGURATION OF THE REPEATERS NETWORK .................................................................................... 14
8. TROUBLESHOOTING..................................................................................................................................... 15

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 3
1. INTRODUCTION
1.1 Purpose of the document
This document is the complete guide for installation, configuration and commissioning of
repeater/receiver wireless service for meters with W. M-Bus protocol (EN13757-4) / OMS, Cod.
SIN.EQRPT868XT hereinafter also called Smart Repeater sinapsitech℗, able to acquire the signal from
one or more measuring devices communicating according to the W. M-Bus standard 868MHz and
retransmit the received data to a network of other sinapsitech℗devices in order to extend the wireless
range of the meters themselves. The data shared by the MESH network are stored by the datalogger
SIN.EQRTU1T. Each SIN.EQRPT868XT handles up to 500 W. M-Bus devices. The plastic container, the
electrical connections totally retractable, the integrated antennas in the same device make the Smarts
Repeaters sinapsitech℗suitable for wall installations also “in view”. Commissioning of SIN.EQRPT868XT
service is facilitated by the software toolkit and on-board LEDs that indicate the signal strength.
Also, the search for the best point of installation is facilitated by the ability to power the device through
its USB port, making possible to move it during the search for the best signal / distance compromise.
1.2 Content of the package
The following are present in the SIN.EQRPT868XT package:
•SIN.RPT868XT Repeater
•2 x 5x25 plugs
•2 x 5x30 screws
•2 x Cable glands
•2 x 2,2x9,5 screws
•1 x clamp headband
•Instructions for installation

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 4
2. SIN.EQRPT868XT TECHNICAL SPECIFICATIONS
SIN.EQRPT868XT is a repeater and receiver for W. M-Bus devices.
The device’s main technical specifications are given below:
•Operating Temperature: [-20..+55°C]
•Storage Temperature: [-25..+85°C]
•Ingress Protection: IP40 (EN60529)
•Protection Class: II
•Mounting: wall, with screws
•Dimensions: LxHxD (160x160x35 mm)
•Power supply: 100..240Vac 50-60Hz
USB (5Vdc, 500 mA) for commissioning
•Consumption: Max 4.5 W
•Frequency: 868 MHz –max. transmission power 27 dBm
•W. M-Bus mode supported: S / T / C+T / S & C+T
•Max distance between two RPT: 500 m in free field - 40 m in buildings
•W. M-Bus area coverage: 250 mt in free field - 25 meters in building

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 5
3. ASPECT OF THE SIN.EQRPT868XT
3.1 Description of the SIN.EQRPT868XT
The devices uses a technology that allows you to expand the W. M-Bus networks, in fact, between them,
the antennas will automatically establish the connection that allows the best signal quality and, upon
receipt of the W. M-Bus plots, spread to the datalogger SIN.EQRTU1T. In the case in which one of the
antennas is turned off or blurred, the network, if possible, is re-created so that all the antennas have a
path to follow up to the datalogger. In this way, in fact, the antenna behaves as a multi-hop repeater. To
this functionality is added the possibility of inserting in the Smart Repeater sinapsitech℗a list of W. M-
Bus devices which represents a white-list, in this way, in the case in which the installation is in an area
where more than 500 W. M-Bus devices are received, the antenna will only take charge of its relevance
devices.
Figure 1 –Example of application of the SIN.EQRPT868XT coupled with a SIN.EQRTU1T
Below find the summary of the main operational features, which will be described in this document:
•Receiver and repeater for W. M-Bus devices (EN13757-4)/OMS
•Multi-hop function mode support
•Easy-to-install thanks to the software supplied
•Wall mounting
•USB interface for local data reading
•WEB interface in conjuction with SIN.EQRTU1T

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 6
3.2 SIN.EQRPT868XT device
Below find an image of the SIN.EQRPT868XT device with indications regarding its operational parts:
Figure 2 –View of RPT868XT
Figure 3 –Connections/buttons/LEDs
1. 100..240Vac power supply input (screw clamps)
2. “Multi-function”button
3. “Multi-function”button
4. Reset button
5. USB Port
6. MESH network TX-RX LED
7. W. M-Bus network TX-RX LED
8. Signal level LED (green colour; active only in scan mode)
9. Status LED (blue colour)
A. Cables compartment lid
B. LED

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 7
4. REPEATER CONFIGURATION THROUGH KEYS FUNCTIONS
4.1 Change ID MESH
The SIN.EQRPT868XT is considered installed and correctly powered..
-If blue led (9) flashes for more than 5 minutes
-If blue led (9) remains fixed access after a few minutes
1. Press keys 2 and 3 (2s. < T <6s) simultaneously.
2. On release all the LEDs (8) will flash at the same time to indicate that you have entered edit mode
ID MESH
3. Now press button 3 (at least 1s.) to switch the MESH ID.
a. ID MESH 1 →Green LED (8.1) on - the others off
b. ID MESH 2 →Green LED (8.2) on - the others off
c. ID MESH 3 →Green LED (8.3) on - the others off
d. ID MESH 4 →Green LED (8.4) on - the others off
4. To SAVE press keys 2 and 3 simultaneously for more than 1s. Press the 2 button to exit without
saving.
5. Verify that the blue LED does not remain on steady. Otherwise, restart from point 1. by selecting
another MESH ID.
6. If, after switching on all four MESH IDs, the blue LED continues to remain on steady, it will be
necessary to configure the SIN.EQRPT868XT via “Equobox Toolkit” code SIN.EQSW1 software.
7. Repeat for each SIN.EQRPT868XT.

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 8
4.2 Activate SND_IR mode (Installation Mode)
a) It typically involves the installation of the AMR system and subsequently the installation of the
heat cost allocators
b) Both the AMR system and the distributors must be configured to work in this mode
c) SND_IR mode activation procedure on a newly installed SIN.EQRPT868XT
1. Press button 2 (t > 6s.). When pressing button 2, the green LED (8.1) flashes every second, until
you are under the 6s. Once the 6s have passed, the LED (8.1) flashes every 500ms →this indicates
that the "SND_IR" scan mode has been changed.
2. RPT enters the "SND_IR" scan mode. RPT receives and takes over all the devices that transmit the
installation W-M-Bus telegram. (This frame contains no data)
3. Scan duration without user intervention 12 hours -> Manual stop of the scan →press key 2 (no
coded pressure time)
Note: SIN.EQRPT868XT automatically exits the SCAN mode after 12 hours.

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 9
4.3 Accept mode activation ALL - SIN.EQRPT868XT
a) It is used when the commissioning is carried out after with respect to the installation of the heat
cost allocators
b) To activate the accept ALL mode on a newly installed SIN.EQRPT868XT
1. Press button 2 (2s. < T < 6s)
2. When pressing button 2, the LED (8.1) flashes every second. When the key 2 is released, the LED
(8.1.) remains lit to indicate the activation of the accept ALL mode.
3. RPT receives and takes charge of all devices transmitting in W.M-Bus including frames in
Installation Mode (SND_IR) - The first green LED lights up permanently - Scan duration without
user intervention 12 hours
4. press the button 2 (no coded pressure time) to stop the scan manually
Note: if during the scan the RPT connects into the MESH network the mode of operation will automatically
change with the value set on the RTU.

SIN.EQRPT868XT –User Guide Rev. 1.6
S I N A P S I S . r . l . | V i a d e l l e Q u e r c e 1 1 / 1 3 - 0 6 0 8 3 B A S T I A U M B R A ( P G ) –I t a l y
T . + 3 9 075 8011604 - F . + 3 9 075 8014602| w w w . s i n a p s i t e c h . i t -i n f o @ s i n a p s i t e c h . i t 10
4.4 SIN.EQRPT868XT –S, T, C+T, S & C+T Mode of operation modification
The SIN.EQRPT868XT is considered installed and correctly powered.
1. Press keys 2 and 3 simultaneously (t > 6s.)
─during the simultaneous pressing of keys 2 and 3, the green LEDs (8.1) and (8.2) will flash every
second, until you are under the 6s. Exceeded the 6s. they flash every 500ms
─When keys 2 and 3 are released, one of the green LEDs (8) starts to flash (500ms) to indicate the
currently active mode of operation on that SIN.EQRPT868XT
2. The mode of operation is changed by pressing the 3 key briefly
•Mode C+T →Green LED (8.1) on - the other off ➔Factory setting
•Mode S →Green LED (8.2) on - the other off
•Mode T →Green LED (8.3) on - the other off
3. save settings by pressing the 2 and 3 buttons (t> 2s.)
4. exit →key 2 for ESC function without saving (during programming status). Automatic ESC from
programming status after 10 minutes later.
Note: SIN.EQRPT868XT automatically exits the SCAN mode after 12 hours.