Sinclair ASV-35BS Manuale utente

Ver. | - -
User Manual
EN
CAMPER TRAILER
ASV-25BS (Wi-Fi)
ASV-35BS (Wi-Fi)
01
06
12
2021

„ORIGINAL INSTRUCTIONS“
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit.
Make sure to save this manual for future reference.

CONTENTS
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the appliance.
R32: 675
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of the
appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
When refrigerant leaks or requires discharge during installation, maintenance, or
disassembly, it should be handled by certified professionals or otherwise in
compliance with local laws and regulations.
This marking indicates that this product should not be disposed with other household
wastes throughout the EU. To prevent possible harm to the environment or human
health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable
reuse of material resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was purchased. They can
take this product for environmental safe recycling.
TROUBLESHOOTING GUIDE ............................................................................................19
ERROR CODE ....................................................................................................................20
ELECTRICAL DATA ..............................................................................................................1
SPECIALIST’S MANUAL ....................................................................................................22
PACKING LIST ......................................................................................................................3
A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT .......................................1
PARTS NAME........................................................................................................................4
OPERATION OF WIRELESS REMOTE CONTROLLER ......................................................5
ELECTRIC DIAGRAM ...........................................................................................................2
CONTROL PANEL ................................................................................................................9
INSTALLATION INSTRUCTION..........................................................................................10
NORMAL MAINTENANCE PROCEDURES .......................................................................21
STEP 3-MOUNTING OUTDOOR UNIT..........................................................................................14
STEP 4-INSTALLING THE CEILING ASSEMBLY .............................................................................15
STEP 5-ELECTRICAL WIRING
..................................................................................................16
STEP 6-COMPLETING THE INSTALLATION .................................................................................18
STEP 2-SELECTING AN INSTALLATION LOCATION & INSTALLING THE ROOF TOP AIR CONDITIONER ......10
STEP 1-STICK SPONGE (SEALING STRIP) AND SPONGE ON THE OUTDOOR UNIT ...............................10

THE REFRIGERANT
WARNING
Appliance filled with flammable gas R32.
Before install and use the appliance, read the owner’s manual first.
Before install the appliance, read the installation manual first.
Before repair the appliance, read the service manual first.
To realize the function of the unit, a special refrigerant circulates in the system. The
used refrigerant is the fluoride R32, which is specially cleaned. The refrigerant is
flammable and inodorous. Furthermore, it can lead to explosion under certain
conditions.But the flammability of the refrigerant is very low. It can be ignited only
by fire.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm
to the ozonosphere. The influence upon the greenhouse effect is also lower. R32
has got very good thermodynamic features which lead to a really high energy effi-
ciency. The units therefore need a less filling.
Appliance filled with flammable gas R32.
regralaeraroolfahtiwmooraniderotsdnadetarepo,dellatsniebllahsecnailppA
than 4 m
2
.
.secruosnoitingignitarepoylsuounitnoctuohtiwmooraniderotsebllahsecnailppaehT
( for example: open flames, an operating gas appliance or an operating electric heater.)
The appliance shall be stored in a well-ventilated area where the room size corresponds
to the room area as specified for operation.
.gnirruccomorfegamadlacinahcemtneverpotsaosderotsebllahsecnailppaehT
Ducts connected to an appliance shall not contain an ignition source.
Keep any required ventilation openings clear of obstruction.
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
esohtnahtrehto,naelcotrossecorpgnitsorfedehtetareleccaotsnaemesutonoD
recommended by the manufacturer.
Servicing shall be performed only as recommended by the manufacturer.
Should repair be necessary, contact your nearest authorized Service Centre.
Any repairs carried out by unqualified personnel may be dangerous.
Compliance with national gas regulations shall be observed.
Read specialist’s manual.

INSTALLATION PRECAUTION
Working temperature range
WARNING:
Otherwise, the cool air can’t be blown out and there will be condensate water on the
Before turning on the unit, please open the horizontal louver of indoor unit by hand.
horizontal louver.
Observe all governing codes and ordinances.
Do not use damaged or non-standard power cord.
Be caution during installation and maintenance. Prohibit incorrect operation
to prevent electric shock, casualty and other accidents.
Suggested working temperature range: -5 ~ 46℃. (heating: -5~24℃/cooling: +18~46℃).
Outdoor unit may stop operation, due to various kinds of protection within working
temperature range.
1. The place with strong heat sources, vapors, flammable or explosive gas, or
2.
5. The place with sulfureted gas.
6. Other places with special circumstances.
7.
volatile objects spread in the air.
The place with high-frequency devices (such as welding machine, medical equipment).
The place near coast area.
The place with oil or fumes in the air.
This air conditioner unit is only used for the vehicle without concave and convex
surface on the top of it.
8.
9.
Prohibit operating this air conditioner unit when starting up the vehicle or when the
vehicle is driving.
Prohibit supplying the power for the air conditioner unit with the vehicle power supply.
Requirement of air conditioner
1.
2. Select a location where the noise and outflow air emitted by the outdoor unit will
Air inlet should be far away from obstacles and do not put any objects near air
not affect neighborhood.
outlet. Otherwise, it will affect the radiation of heat-removal pipe.
3.Please try your best to keep far away from fluorescent lamp.
4.
Selection of Installation Location
3.
The appliance shall not be installed in the laundry.
4.
Basic requirement
Installing the unit in the following places may cause malfunction. If it is unavoidable,
please consult the local dealer:

Requirements For electric Connection
Safety precaution
8. The yellow-green wire or green wire in air conditioner is grounding wire, which
9.
10. The appliance shall be installed in accordance with national wiring regulations
3.
Must follow the electric safety regulations when installing the unit.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work related t o electricity and safety.
4.
5.
with specialized grounding device by a professional. Please make sure it is
always grounded effectively, otherwise it may cause electric shock.
can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
1.
For appliances with type Y attachment,the instructions shall contain the
substance of the following.If the supply cord is damaged,it must be replaced by
avoid a hazard.
INSTALLATION PRECAUTION

AIR CONDITIONING UNIT
A FEW WORDS ABOUT YOUR NEW
1.
ELECTRICAL
DATA
2.
3.
4.
All wiring must be complied with local and national electrical codes. All wiring
must be installed by qualified electricians. If you have
any questions about the
following instructions, contact a qualified
electrician.
The wiring diagrams are located on the cover of the control box. The assembly unit
wire diagrams are located on the ceiling panel.
5.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
6.
The Electric schematic diagram are subject to change without notice. Please refer
to which one on the unit.
Check the available power supply and resolve any wiring problems BEFORE installing
and operating this unit.
- 1 -
This air conditioner is designed to operate from a 220-240V AC, 50Hz, 1 Phase
power supply.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should
be connected in fixed wiring.
Including an air switch with suitable capacity, Air switch capacity:10A.
Air switch should be included magnet buckle and heating buckle function, it can protect the
circuit-short and overload.
Thank you for choosing the Recreational Vehicle Air Conditioner.
This manual will supply you with all the information for installation, operation and maintenance.
Take a few minutes to discover how to get the most in cooling comfort and economic operation
from your new air conditioner.
Please keep this manual well for future reference.

ELECTRIC DIAGRAM
Roof Top Air Conditioner
- 2 -
Ceiling Assembly
AP2
LAMP
MODULE
OUTDOOR UNIT
AP1
DISPLAY
CN1
DISP1
BOARD RT1 ROOM
SENSOR
ROOM
AP3
WIFI
MODULE
WIFI
0
OPTIONAL
CONNECTOR
CONNECTOR
CAP. WH
BU
S
BU
R
C3
INDOOR UNIT
OUTROOM
SENSOR
N14WAY
VALVE
4-WAY
4YV
NCOMP
AC-L
PE
BU
BN
YEGN
AP1
TUBE SENSOR
OUTDOOR
RT1
TUBE
SENSOR
RT2
MAIN BOARD
RT3
(20K) (15K)(20K)
(WH) (BK)
VT VT
K7
DISP1
T-SEN
MOTOR
IN_FAN
0
0
0
C
RD
COMP
COMP.
L
N
POWER
PE
M2
YEGN
MOTOR
OUT_FAN
C2
RD BN
CAP.
M1
C1
RD BN
CAP.
FAN
YEGN
PE
OFAN

PACKING LIST
owner’s manual
Bolt sub-assy
M8X135
Mounting plate remote controller
Remote controller holder
Double-sided
gummed paper
Foam (accessory)
Sunk screw
(remote controller holder) Foam (up)
Mounting plate sub-assy
Insulating sheath
Tapping screwBolt sub-assy M6X25
Sponge (foam accessory)
Sponge (sealing strip) Sponge Bundle
battery
(AAA 1.5V)
- 3 -
LED

PARTS NAME
Indoor Unit
Filter sub-assy Air-in grille
LED indicator
Air-out grille
Control panel (membrane)
remote controller
Outdoor Unit
Outer case
Air-in grille
Drainage outlet Chassis
(Display content or position may be different from above
graphics, please refer to actual products)
- 4 -
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
LED
Questo manuale è adatto per i seguenti modelli
1
Indice

















