1. Safety Instruction
Please make sure that the power voltage being used matches with the supply voltage of gate opener
(AC110V or AC220V); kids are not allowed to touch the control devices or the remote-control unit.
The remote-control unit is single button mode or three button mode (please refer to the instructions
of the remote control in accordance with the actual gate opener type). The indicator light on the
remote-control unit will flicker when its button is pressed. Main engine and gate can be unlocked
with a disengagement wrench and the gate can be manually operated after disengagement.
Please make sure that nobody is around the main engine or gate when the switch is operated.
Please temporarily stop using the product if the main engine needs to be repaired or regulated. The
installation and maintenance of the product must be carried out by professionals.
Please read this manual carefully before installing、using、maintaining or repairing it. Without
following this manual, any injury or property losses caused by improper use or unauthorized
modification is out of the responsibility of our company.

2
2. Packing List (standard)
No.
Picture
Name
Quantity
1
Main engine
1
2
Manual release key
2
3
A
B
C
D
A
B
C
D
Remote control
2
4
Spring limit switch
accessories box / Magnetic
limit switch accessories box
1
4-1
or
Spring limit switch block
/ Magnetic limit switch block
1
4-2
Limit switch block mounting
screw M6X18
4
4-3
Foundation bolt M8
4
4-4
Nut M8
8
4-5
Flat washer Ø8
8
4-6
Spring washer Ø8
4

3
2. Packing List (optional)
No.
Picture
Name
Quantity
1
Steel gear rack
1m/pc
2
Nylon gear rack
1m/pc
3
Infrared sensor
1
4
0
8
5 6
97
4
1 2 3
Wireless keypad
1
5
Alarm lamp
1
6
Mounting plate
1
7
Protect cover for output gear
1
8
Hexagon head bolt M8×60
4
3. Technical parameters
Model
SL600AC
Power supply
220V/50Hz;110V/60Hz
Motor power
280W
Gate moving speed
11-13m/min

4
Maximum weight of gate
600Kg
Remote control distance
≥30m
Remote control mode
Single button mode
/ Three button mode
Limit switch
Spring limit switch
Magnetic limit switch
Noise
≤58dB
Working duty
S2, 15min
Recording of up remote controls
25
Frequency
433.92 MHz
Working temperature
-20°C ~ +70°C
Package weight
9.4Kg
4. Installation
SL600AC sliding gate opener is applicable to gate weight less than 600kg, and length of the sliding
gate less than 12m. The drive mode adopts the rack and gear transmission. This gate opener must
be installed inside the enclosure or yard for protection.
4.1 Installation drawing
⑤
④
③
②
0
8
5 6
97
4
1 2 3
⑧
①
⑦
⑥
Figure 1
①Gate opener; ②Wireless keypad (optional); ③Gate; ④Infrared sensor (optional);
⑤Alarm lamp (optional); ⑥Safety stop block; ⑦Gear rack; ⑧Remote control;

5
4.2 Size of main engine and accessories
4.2.1 Size of main engine
251
260
227
Figure 2 (1) Spring Limit Switch
260
251 225
Figure 2 (2) Magnetic Limit Switch
4.2.2 Size of mounting plate

6
107
150
204±0.3
90±0.3
8×10
Φ
Figure 3
4.3 Installation procedures
4.3.1 Preparation work before installation
Please make sure that the sliding gate is correctly installed, the gate rail is horizontal, and the gate
can be manually moved smoothly before installing the gate opener.
Cable installation
In order to guarantee the normal operation of the gate opener and protect the cables from damages,
please bury the motor & power cable and controlling cable separately with two PVC tubes.
Concrete pedestal
Please precast a concrete pedestal with the size can be 400mm x 250mm, depth be 200mm in
advance, so as to firmly install SL600AC gate opener. Please make sure the distance
between the gate and gate opener is appropriate before casting the pedestal.
Embedded screws
Concrete
Power line
Mounting plate
Foundation bolt
Figure 4
4.3.2 Main engine installation
a) Dismantle the plastic housing on the main engine before installation and keep relevant fasteners

7
properly;
b) Please prepare the power line for connecting the mounting plate to the main engine (the number
of power supply cable cores should not be less than 3 PCS, the sectional area of cable core should
be over 1.5mm²and the length should be determined by users according to the situation on
installation spot.)
c) Please unlock the main engine before installation, the unlock method is: insert the key, open the
manual release bar till it rotates by 90°as shown in Figure 5. Then turn the output gear and the gear
can be rotated easily;
Turn on 90°
Figure 5
4.3.3 Gear rack installation
Fix the mounting screws to the rack.
Put the rack on the output gear, make the rack engage with the output gear then weld the
mounting screw to the gate (each screw with one solder joints firstly).
Manually move the gate (gate should be moved smoothly after motor unlocked) to check
whether there is a fit clearance between rack and output gear, as shown in Figure 7.
Weld all the mounting screws to the gate firmly.
Make sure that all racks on the same straight line.
Pull the gate after installed, make sure the entire trip is flexible without any stuck.
Figure 6
The fit clearance of output gear and rack is shown in Figure 7 below:

8
1-21-2
GearGear rackrack
OutputOutput geargear
mmmm
Figure 7
Warnings
·To ensure safety, install safety stop blocks on both ends of the rail to prevent the gate from running
out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place
and whether it has the function of preventing the gate from running out of the rail or safety range.
·Please make sure that the main engine and its components have good mechanical properties, and
the gate can be operated flexibly when manually moved before installing the main engine.
·Please note that for this product, one control can only drive one main engine, otherwise, the control
system will be damaged.
·Earth leakage circuit breaker must be installed in where the gate movement can be seen, and the
minimum mounting height is 1.5m to avoid being touched by children.
·After installation, please check whether the mechanical property is good or not, whether gate
movement after manual unlocking is flexible or not, whether the installation for infrared sensor
(optional) is correct and effective.
4.3.4 Limit switch adjustment
Spring limit switch - The installation position of spring limit switch is shown in Figure 8:

9
GateGate
SpringSpring limitlimit switchswitch
SpringSpring limitlimit switchswitch stopstop blockblock
GearGear rackrack
OutputOutput geargear
Figure 8
The installation of spring limit switch stop block is shown in Figure 9:
M6×18M6×18 M6×18M6×18
Figure 9
Magnetic limit switch - The installation position of magnetic limit switch is shown in Figure 10: