Skope SCS Connect Manuale utente

SCS Connect
Electronic Controller
Technicians’ Manual
MAN80199 Rev. 1.2 May 2023

SCS Connect Electronic Controller
Technicians’ Manual
MAN80199
Rev. 1.2 May 2023
© 2019 SKOPE Industries Limited. All rights reserved.
SKOPE Industries Limited reserves the right to alter specifications without notice.
is a registered trademark of SKOPE Industries Limited.
SKOPE INDUSTRIES LIMITED
Head Office
PO Box 1091, Christchurch
New Zealand
A.B.N. 73 374 418 306
AU: 1800 121 535
NZ: 0800 947 5673
E-mail: [email protected]
Website: www.skope.com
Trademark Infringement
The SKOPE trademark on this product is infringed if the owner, for the time being, does
any of the following:
• Applies the trade mark to the product after its state, condition, get-up or packaging
has been altered in any manner
• Alters, removes (including part removal) or obliterates (including part obliteration) the
trade mark on the product
• Applies any other trade mark to the product
• Adds to the product any written material that is likely to damage the reputation of the
trade mark
Notice of the above contractual obligations passes to:
• Successors or assignees of the buyer
• Future owners of the product

SKOPE SCS Connect Electronic Controller
Technicians’ Manual iii
Contents
1 Controller
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Controller Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Buttons and Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Service Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Application Procedures
App Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Field App . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
App Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Home Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
App Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Output Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Edit Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Load Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SCS Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
SCS Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Deactivate SKOPE-connect . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Reset Cabinet IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Track App . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
3 Faults and Alarms
4 Service Procedures
Exchanging a Refrigeration Cartridge . . . . . . . . . . . . . . . . . . . . . . . . 23
Swapping a Faulty Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23

4Controller
Technicians’ Manual
SKOPE SCS Connect Electronic Controller
1 Controller
Overview
The cabinet is fitted with an SCS Connect electronic controller, which is pre-programmed.
SKOPE does not recommend changing the settings unless it is absolutely necessary. To
ensure efficient operation, the controller automatically forces a defrost cycle when required.
Controller Faceplate
Buttons and
Display The faceplate includes the front display panel and interface buttons.
Table 1: Controller faceplate
No. Description Use
1 Night Mode Indicator On during night mode.
2 Display Indicator
Digital display of:
• the cabinet’s air (not product)
temperature.
• alarm messages.
3Light Switch - Night Mode
(back/abort) Button Used during programming.
Press to switch the lights on or off.
Press and hold to switch the cabinet
between Day and Night modes.
4 Up Button Used during programming.
5 Bluetooth Indicator Off when ready to connect to a device. On
and flashing when connected to a device.
6 Defrost Cycle (next/enter) Button Used during programming. Press and hold to start a manual
defrost.
7 Down Button Used during programming.
8 Fault - Alarm Indicator On during a fault or alarm.
9 Compressor Indicator On when the compressor is running.
10 Defrost Cycle Indicator On during the defrost cycle.
11 Evaporator Fan Indicator On when the fans are running.
1234 5
87
11
10
96

5
SKOPE SCS Connect Electronic Controller
Controller
Technicians’ Manual
Service Mode The service mode can be run using the controller faceplate, but SKOPE strongly
recommends using the SCS Connect Field app. You will need a 9-digit PIN to enter the
service mode via the controller. If you don’t have one, contact your User Manager (Corporate)
or SKOPE Customer Services (General Market) to request a PIN.
Service mode includes:
Parameters
Allows you to access and edit individual controller parameters.
Reset
Returns the controller back to factory or default settings.
Manual test
Allows you to see the input values from the sensors, check the effects of output adjustments
to peripherals, and run preset test routines.
Statistics
Displays logged values and event counts for diagnostics and fine tuning.
About
Lists the properties of the refrigeration system and the controller, including fridge model
codes, and firmware, hardware and software versions.
Refer to AoFrio documentation for further information.

6Application Procedures
Technicians’ Manual
SKOPE SCS Connect Electronic Controller
2 Application Procedures
App Access
Field App
The SCS Connect Field app gives authorised service technicians wireless access to the
controller from mobile devices with Bluetooth capability. The app provides data logging, alarm
notification, and control over inputs (e.g. probes and switches) and outputs (e.g. relays).
App
Categories Various options are available in the app menu which provide information about the connected
controller and its cabinet. Depending on user access level, some menu options may not be
available.
Home Screen The home screen shows a graphic representation of the current state of the cabinet being
controlled.
Procedure 1: To access an app
1. Download and install the Connect Field app:
•SCS Connect Field App
For SCS Connect Field app installation, see Quick Start Guide PRN80176.
•SCS Connect Track App
For SCS Connect Track app installation, see Quick Start Guide PRN80177.
2. Open the required app on your smart device.
Operating mode
(normal/standby)
Evaporating
temperature
Light status
Input voltage
Compressor status
Evaporator fan
Cabinet temperature
Event
Door status
Perishable/
Non-perishable mode
Condenser fan
Condensing
temperature

7
SKOPE SCS Connect Electronic Controller
Application Procedures
Technicians’ Manual
Note: Only inputs connected to, or components directly controlled by, the SCS Connect
controller will be displayed upon the Home Screen. For example, if the condenser fan is
directly driven from the compressor then the condenser fan icon will not be displayed on the
home screen.
Events (Alarms or Faults) can be accessed directly from
the home screen. This allows you to view details about
the fault, as well as the history of the recorded faults.
Tap on any component showing the small yellow triangle
symbol to view the current event.
From the details screen you can see the possible cause,
along with a current reading and any parameters that may
be related to the fault.
You can view the event history for that component by
tapping the yellow triangle beside Event History.
App Menu The menu (three horizontal bars on the top right hand side) provides access to the first level
of the app’s functions.
Table 2: App menu items
Menu item Description
Home Returns to the home screen
Output control Output control screen
Edit parameters Access the parameters for editing
Load parameter file Select a parameters file from local or cloud storage
Statistics Review the controller’s statistics
SCS info Details of the SCS controller
SCS setup Set up and change asset information
Disconnect Disconnect the app from the controller
Settings App settings
IMPORTANT
After connecting to or modifying any controller, always disconnect
your device from the controller to confirm all changes.
IMPORTANT
Always power cycle the cabinet if:
• changing time-based parameters.
• updating a significant number of parameters.
• updating the firmware.
App menu

8Application Procedures
Technicians’ Manual
SKOPE SCS Connect Electronic Controller
Output Control Displays real time data when connected to the cabinet by allowing real
time interaction with both inputs (probes, switches) and outputs
(relays, pulse width modulation (PWM)).
Note: Any selected output changes override any priorities in the
controller, but are limited to 2 minutes before resetting to their
previous status.
You can add or remove inputs or outputs via the + button. This will add
or remove a trace line from the live chart.
Only relays that are being used can be switched.
If the fan motor is a controlled speed motor, operating speeds are
shown. A negative number shows counterclockwise rotation.
Edit
Parameters Parameters are arranged in categories to help with navigation. Drop-down boxes give lists of
available parameters – scroll up and down for the complete list.
Only parameters needed to operate the cabinet will be visible. These may differ between
cabinet types.
Each category contains the parameters associated with that mode.
Updates are not applied until you disconnect from the controller.
CAUTION
Do NOT switch the compressor on and off without allowing
pressure to equalise in between. Switching on and off may cause
permanent damage to the compressor, leading to failure.

9
SKOPE SCS Connect Electronic Controller
Application Procedures
Technicians’ Manual
When a parameter is selected, a new screen opens allowing you to modify the parameter.
Load
Parameters You can download the SKOPE factory parameters files stored in the cloud using the Field
App when you are:
• installing a new controller.
• trying to diagnose a fault and you think that the parameters may have been corrupted or
modified.
To ensure that you have the most recent parameters file SKOPE recommends you always
download the latest release from the cloud.
If you are going to a location without a data connection, follow Procedure 3 before you travel.
Procedure 2: To change a parameter
1. Select the parameter.
2. Make the adjustments, using the slider, or the - and + buttons.
3. Save the using the Enter button within the newly opened screen.
The maximum and minimum allowances for each parameter are shown, along with a Default
button.
4. Note the details of your changes on the warranty and/or service documentation, including:
•the original setting.
•the new setting.
•reasons why the change was made.
5. To apply the updates, disconnect from the controller.
IMPORTANT
Do NOT press the Default button.
The Default button sets the parameter back to AoFrio defaults,
not SKOPE defaults.

10 Application Procedures
Technicians’ Manual
SKOPE SCS Connect Electronic Controller
Procedure 3: To download a parameters file
Before you start
Ensure you have a data connection.
1. Select Load Parameter File.
The Select Configuration File page shows the status of the
currently selected file and gives the option of selecting a new
file.
2. Press Select File.
3. Select the Server radio button. A list of files will load.
4. Select the relevant file, and press Download.
You must only use released files.
5. Click Local to check that the file has downloaded.
Procedure 4: To load a parameters file
Before you start
Ensure you either have a data connection, or have downloaded the most recent parameters file from
the cloud.
1. Select Load Parameter File.
The Select Configuration File page shows the status of the
currently selected file and gives the option of selecting a new
file.
2. Press Select File.
3. Select either Local or Server, depending on your data
connection, and make sure you have the most recent
parameters file.
You must only use released files.