9
BB380r-2, BB580r-3, BB780r-4
SKOPEBackbarRemote Chillers
2.2Refrigeration System
Drain
A500mm long, 19mm O.D. PVC drain hose is supplied. All drainage
is to conform to local regulations, covering removal of condensate to
waste water. Ensure drain is trapped with adequate fall. Venting the
drain may be required for a restrictive run.
Refrigeration lines
A 1/4” liquid line, and 3/8” suction line are provided to attach pipe
lines to. The suction lines must be insulated.
NOTE:The electronic controller supplied with the cabinet can switch
a solenoid. No solenoid is supplied with the remote unit.
Refrigeration Practice
Installation must be performed by arefrigeration tradesperson, to an
appropriate standard complying with all local regulations.
Performance depends on the overall installation (including
condensing unit). Cabinet suitability must always be quantified for
the application. The final responsibility for condensing unit
performance and component selection rest with the installer. The
installer must check matters such as:
•Heat load
•Refrigeration load
•Variable operating conditions (usage, ambient, humidity)
•Refrigeration pipe sizing
•Refrigeration pipe length (distance, elevation, pressure drop)
•Location and ventilation (cabinet and condensing unit)
•Drainage
NSTALLAT ON
2