Skov DOL 2400 Manuale utente

DOL 2400 • DOL 2300
Alarm System
User Manual
612541 • 2022-12-23 Software version 4.5
English For other language variants of this document we refer to:
Español Para otras variantes del idioma de este documento, visite:
Français Pour les versions dans d'autres langues de ce document veuillez consulter:
http://docs.skov.com/1095


DOL 2400 • DOL 2300
1 Product description ....................................................................................................................................... 5
2 User guide....................................................................................................................................................... 7
2.1 Handling alarms ......................................................................................................................... 8
2.1.1 Stop alarm with phone call........................................................................................................... 9
2.1.2 Stop alarm with SMS message.................................................................................................... 9
2.1.3 Video streaming via mobile in the event of an alarm ................................................................... 9
2.2 Pages ........................................................................................................................................ 10
2.2.1 The page Overview.................................................................................................................... 10
2.2.2 The page Outputs ...................................................................................................................... 12
2.2.3 The I/O Overview Page.............................................................................................................. 13
2.2.4 The page Activity log.................................................................................................................. 14
2.2.5 Select display language ............................................................................................................. 15
2.2.6 Editing and creating pages ........................................................................................................ 15
2.3 Settings..................................................................................................................................... 18
2.4 Remote control......................................................................................................................... 19
2.4.1 Entering phone numbers............................................................................................................ 19
2.4.2 SMS commands......................................................................................................................... 20
2.5 Voice messages from the alarm unit ..................................................................................... 21
2.6 Surveillance.............................................................................................................................. 22
2.6.1 Activation of surveillance ........................................................................................................... 22
2.6.2 Deactivation of surveillance alarm ............................................................................................. 22
2.7 Details menu............................................................................................................................. 23
2.7.1 Overview .................................................................................................................................... 23
2.7.2 Temperature alarms (Only DOL 2400) ..................................................................................... 24
2.7.2.1 Setting temperatur alarm limits .................................................................................................. 25
2.7.2.2 Temperature setpoint................................................................................................................. 25
2.7.2.3 Summer rise............................................................................................................................... 26
2.7.3 Log ............................................................................................................................................. 28
2.7.4 Function test .............................................................................................................................. 28
2.7.4.1 Manual test - with reminder........................................................................................................ 29
2.7.4.2 Automatic testing ....................................................................................................................... 29
2.7.5 Sound......................................................................................................................................... 30
2.7.6 System status ............................................................................................................................ 30
2.7.7 Supervision of the alarm unit’s input terminals .......................................................................... 31
2.7.7.1 Stop input supervision................................................................................................................ 31
2.7.8 Service break ............................................................................................................................. 32
2.8 Phone ........................................................................................................................................ 32
2.9 User login ................................................................................................................................. 34
3 Maintenance instructions ............................................................................................................................ 36
3.1 Recycling/Disposal .................................................................................................................. 36
4 Utility table for finished tests ...................................................................................................................... 37
User Manual

DOL 2400 • DOL 2300
4 User Manual
Product and Documentation Changes
SKOV A/S reserves the right to change this document and the product herein described without further notice.
In case of doubt, please contact SKOV A/S.
The date of change appears from the front and back pages.
In case of an operating error or improper use, alarm systems can cause production losses or the
loss of lives among animals.
SKOV A/S recommends that alarm systems be mounted, operated and serviced only by trained
staff and that the emergency opening and alarm system be maintained and tested at regular inter-
vals, in accordance with SKOV A/S´s terms and conditions of sales and delivery.
The installation must be carried out by an authorized electrician and according to current national
regulations and in the EU also applicable EU regulations.
SKOV A/S recommends that prepaid mobile service cards are not used for alarm units with mobile
modem.
SKOV A/S recommends that the alarm unit is connected to its own separate telephone line to en-
sure optimum use and safety. It is therefore important to avoid connecting the alarm unit together
with, e.g. a fax machine.
Note
• All rights belong to SKOV A/S. No part of this manual may be reproduced in any manner whatsoever without
the expressed written permission of SKOV A/S in each case.
• All reasonable efforts have been made to ensure the accuracy of the information contained in this manual.
Should any mistakes or imprecise information occur in spite of this, SKOV A/S would appreciate being noti-
fied thereof.
• Irrespective of the above, SKOV A/S shall not accept any liability with regard to loss or damage caused or
alleged to be caused by reliance on any information contained herein.
• Copyright by SKOV A/S.

DOL 2400 • DOL 2300
User Manual 5
1 Product description
The DOL 2400/DOL 2300 alarm system is primarily used to monitor ventilation in livestock houses. The alarm
system collects all incidents such as alarms and operation in a joint log, which can be used for analysis and sta-
tistics. The system can also be used for triggering alarms at equipment errors and other alarm situations.
Without extension the DOL 2400 can monitor the temperature in up to 20 house sections.
The alarm unit is not a fire alarm device, but when an additional sensor is connected to DOL 2400, it can signal
a rapid temperature rise, which may indicate an ignition in the building. This feature is for informational purposes
only and cannot replace a fire alarm. It is also possible to set up the DOL 2400 with surveillance to prevent
unauthorized visitors from entering livestock houses.
Camera
Outside temperature sensor
Silo and water alarm
Climate/Production
Mobile/fixed-line
Horn
Flash
Climate backup
Figure1: DOL 2400 alarm system
The alarm system consists of the DOL 2400/DOL 2300 alarm unit, input providers such as sensors and house
controllers, and alarm indicators such as horns or text messages.
The DOL 2300 is a reduced edition of the DOL 2400. The DOL 2300 is different from the DOL 2400 in that it
only has ON/OFF inputs and no climate backup and outputs. See the table ‘DOL 2400 and DOL 2300 function-
ality’.
The alarm unit is available in several variants - with or without a fingerprint reader - and two sizes - with 10 or 20
inputs. Depending on the variant DOL 2400/2300 can notify alarms in a clear voice and send warnings via SMS,
while the user can call or send an SMS to the unit to get alarm status or to acknowledge alarms. SMS is avail-
able when the alarm unit is fitted with a GSM modem. Furthermore, a fixed-line modem is available for areas
with poor mobile coverage.

DOL 2400 • DOL 2300
6 User Manual
Accessories
As an accessory, an extension box comes with a further ten terminal inputs. Up to eight extension boxes can be
connected to a large alarm unit and nine to a basic unit. Place the extension boxes immediately next to the
alarm unit. Another extension option is to use a DOL 2400/DOL 2300 in a Master/Client system. It can be done
in a LAN network, mainly where the alarm system covers a geographically large area. You can use up to nine
client units in the same system.
Functions DOL 2400 DOL 2300
Universal inputs:
• Temperature Yes No
• Digital ON/OFF Yes Yes
• Analogue Yes No
• Other sensor types (see below) Yes No
Outside temperature sensor Yes No
Phase break relay Yes Yes
Climate backup Yes No
Video streaming (SMS with browser view URL) Yes No
Outputs Yes No
Master/client Yes Yes
Surveillance Yes No
Table1: DOL 2400 and DOL 2300 functionality.
10" and 7" display
The displays shown in this manual are from a 10" display where the menu overview is shown to the left in the
display. If you use an alarm unit with a 7” display, the menus are shown in the middle of the display.
Using a 7” display you can press the menu headlines at the top
of the display to go back step-by-step in the menus.
If more steps are available that what can be shown, you can
press the 3 dots and select a menu from the appearing list.

DOL 2400 • DOL 2300
User Manual 7
2 User guide
The alarm unit is operated by means of the touch display.
The view in the display is called a page. One page can contain more information than what you can immediately
see, and you can scroll up and down on the page.
BDE
F
G H I J K
L
A
C
Figure2: 10" display.
BDE
F
L
G
H
I
J
A
K
C
Figure3: 7" display.
AThe page content.
BShortcuts to available pages.
CShortcut to activity log.
DThe name of the alarm unit and the time of day.
EThe icon and name of the displayed page.
FAccess to Settings and language selection. See also Select display language [}15].
GDisplay of outside temperature, if outside temperature sensor is connected. Not possible for all vari-
ants.
HDisplay of telephone status. See also Remote control [}19].
IDisplay of the phase break status. See also the Technical Manual.
JDisplay of the battery status. See also Maintenance instructions [}36].

DOL 2400 • DOL 2300
8 User Manual
KDisplay of the output status.
LAccess to page setup. See also Editing and creating pages [}15].
The colors of the icons, the text and lines on the pages show the current status of the function.
Green: All is OK
Red: Alarm
Yellow: Supervision of the function is disabled
Orange: The livestock house is set for service break / warning
Empty: Nothing is installed on this input
2.1 Handling alarms
The alarm units displays the alarms as a pop-up.
There are two types of alarm:
Hard alarm:
Red alarm pop-up on the alarm unit. At the same time local
alarms such as horns and flashes are triggered, and alarms are
also sent by phone calls and SMS message.
Silent alarm (soft):
Yellow warning pop-up on the alarm unit and registration in the
activity log.
See the Technical Manual about setting up inputs.
In the event of a power failure, local alarms with horns and
flashes will change from constant to pulsing.
The icon for the activity log indicates the number of active
alarms, as long as an alarm situation has not ended.
The icon for the inputs with alarm is also red/yellow on the page
Overview.

DOL 2400 • DOL 2300
User Manual 9
Acknowledging alarms
Press Acknowledge to stop the alarm and calls.
Alarms can also be acknowledged by:
• sending an SMS message to the alarm unit. See Stop alarm
with phone call [}9].
• calling the alarm unit. See Stop alarm with phone call
[}9].
• acknowledging the alarm via the management programme
FarmOnline Explorer.
The alarm unit cannot be operated before alarms have been ac-
knowledged.
Login
The alarm unit can be set up so that the user must log in - with code or fingerprint (applies only to alarm units
with fingerprint scanner) - to be able to acknowledge alarms. See User login [}34].
Temporary remote acknowledgment - snooze
The alarm unit can be set up for temporary alarm acknowledg-
ment via phone, SMS message or FarmOnline Explorer. If the
alarm situation continues, the alarm unit activates the alarm
again after 15 minutes (setting).
See the Technical Manual.
2.1.1 Stop alarm with phone call
In case of alarm the alarm unit makes a call (only with mobile ((GSM)) or fixed-line modem).
• Stop the alarm by answering the call and pressing 1 on the phone to acknowledge the alarm. Press 2 for the
next alarm. Press 9 to repeat the alarm.
• The alarm unit acknowledges the alarm.
2.1.2 Stop alarm with SMS message
In case of alarm the alarm unit sends an SMS message (only with mobile modem).
• Stop the alarm by responding to the SMS alarm and sending the text ACK.
• The alarm unit acknowledges the alarm and sends an SMS confirmation stating that the alarm has been ac-
knowledged.
2.1.3 Video streaming via mobile in the event of an alarm
• DOL 2400 can can connect up to 20 cameras, which can display what is happening in the livestock house
during an alarm.
• DOL 2400's alarm SMS message can include a link to a web camera in the alarm location. As such, it is
possible to gain access to the live streaming from the camera.

DOL 2400 • DOL 2300
10 User Manual
2.2 Pages
We recommend that you create a number of pages to show exactly the necessary functions and values and
cover the needs of the daily user. See also Editing and creating pages [}15].
The pages work as shortcuts to the key values and settings and therefore gives you quick access to reading val-
ues and changing some settings.
The individual key values shown on the pages are also called cards.
2.2.1 The page Overview
Gives an overview of the installed alarm inputs and their status and provides a shortcut to the setup of the in-
puts. Each input appears as a card on the page.
C
D
A
B
E
AThe icon for the Overview page.
BThe icon and name of the displayed page.
CCard for the each input.
DThe color of the card shows the current status of the input.
No color: OK
Red: Alarm
Yellow: Warning
Grey: Supervision of the input is paused
EThe 3 dots indicate that pressing the card will display additional information and give access to reading
current values and settings and to enable or disable supervision of the input.
Depending on the type of input pressed, the card will display additional information such as:
Supervision Enabling and disabling supervision of the input. See the section Stop input super-
vision [}31].
Setpoint The set value for the input.
Alarm limit The value that will trigger the alarm if exceeded.
Altri manuali per DOL 2400
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Skov Sistema di sicurezza
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente