4
6
VIEW WITHOUT COVER
8
BOTTOM VIEW OF COVER
9
7
5
2
3
1
Copyright © 2001 SloanValve Company
Parts List —EHD Hand Dryer
Item Part Code Description
No. No. No.
1 EHD-93 0305427 Mounting Hardware (Not Shown)
2 EHD-127 0305438 Lock Washer (4 Required)
3 EHD-17 0305437 Cover Screw (4 Required)
4 EHD-214-A 0305574 Chassis Assembly, 120 VAC
EHD-215-A 0305540 Chassis Assembly, 208 VAC/240 VAC
5 EHD-182-A 0366002 Power Board Assembly, 120 VAC
EHD-183-A 0366003 Power BoardAssembly, 208 VAC/240 VAC
6 EHD-216-A 0305577 Blower Assembly, 120 VAC
EHD-217-A 0305541 Blower Assembly, 208 VAC/240 VAC
7 EHD-11-A 0305401 Heater Assembly, 120 VAC
EHD-14-A 0305543 Heater Assembly, 208 VAC/240 VAC
8 EHD-184-A 0366004 Exhaust Grille/Fiber Optic Cable Sub-Assembly
9 EHD-204-A1 0305709 Cover Assembly, White
EHD-204-A2 Cover Assembly, Black
EHD-204-A3 0305711 Cover Assembly, Almond
EHD-204-A4 0305712 Cover Assembly, Gray
NOTICE:The information contained in this document is subject to
change without notice.
SLOAN VALVE COMPANY •10500 Seymour Avenue• Franklin Park, IL 60131
Phone: 1-800-9-VALVE-9or 1-847-671-4300 •Fax:1-800-447-8329 or 1-847-671-4380
http://www.sloanvalve.com
Printed in U.S.A. 01/01
Table 4 — Power Board and Sensor Replacement Kits †
Production
Dates Voltage
Power
Board
Part No.
(Obsolete)
Sensor
Part No.
(Obsolete)
Sensor/Power
Board Replacement
Kit Part No.
(Code No.) ‡
1986 - 1991 120 VAC EHD-12-A EHD-13-A EHD-1006-A (3366007)
208/240 VAC EHD-65-A EHD-13-A EHD-1007-A (3366008)
1991 - 1995 120 VAC EHD-12-A EHD-234-A EHD-1006-A (3366007)
208/240 VAC EHD-65-A EHD-234-A EHD-1007-A (3366008)
1995 - 1999 120 VAC EHD-1004-A EHD-1003-A EHD-1006-A (3366007)
208/240 VAC EHD-1005-A EHD-1003-A EHD-1007-A (3366008)
†Power Boards and Sensors are no longer available for EHD Hand Dryers
manufactured prior to June 1999. When servicing this older product, both the
Power Board and Sensor must be replaced using the Sensor/Power Board
Replacement Kits listed in Table 4 above.
‡The Sensor/PowerBoard Replacement Kitsinclude Sloan’slatest technology
Power Board Assembly (Item No. 5), Exhaust Grille/Fiber Optic Cable
Sub-Assembly (Item No. 8), Wiringand Installation Instructions.
WHEN SERVICING OLDER SLOAN EHD HANDDRYERS
Sloan Valve Company is dedicated to providing sensor operated
productsthat incorporatetoday’slatestelectronictechnologies.Tokeep
pacewith thesenewtechnologiesitisoftennecessarytomake changes
to our products. Current EHD Hand Dryer Power Boards and OPTIMA
Fiber Optic Sensors will operate in older Sloan EHDHand Dryersif the
following conditions are met:
•Hand dryers built between September 1995 and June 1999 used
Power Board Assemblies EHD-1004-A (120 VAC) and EHD-1005-A
(208/240 VAC) and OPTIMA Sensor Assembly EHD-1003-A. These
unitscanbeidentifiedbyaRangePotentiometerlocatedonthePower
Board.
•Hand dryers built before September 1995 used Power Boards
EHD-12-A (120 VAC) and EHD-65-A (208/240 VAC) and OPTIMA
Sensor EHD-234-A (EHD-13-A if built before 1991). These units can
be identified by a Range Potentiometer located on the OPTIMA
Sensor (NOT on the Power Board).
IF EITHER THE POWER BOARD OR THE OPTIMA SENSOR HAS
FAILED IN AN OLDER UNIT, BOTH COMPONENTS MUST BE
REPLACED.
Note: Hand Dryers built before 1991 included a flashing indicator light
visiblethroughawindowontheHandDryerCover.ReplacementCovers
no longer furnish the indicator light; therefore, disconnect and remove
the light if replacing the Cover or OPTIMA Sensor.
6