Smacq Technologies Co., Ltd. PS2016 Series Manuale utente

PS2016 Series High Precision Isolated Data Collector
PS2016V /PS2016I
PS2016V-485 /PS2016I-485
User Manual
Rev: D
Beijing Smacq technologies Co., Ltd.
www.smacq.com
www.smacq.cn

2
Content
1. PRODUCT OVERVIEW...............................................................................................................3
1.1. GENERAL INTRODUCTION ...............................................................................................................3
1.2. PRODUCT FEATURES ......................................................................................................................3
1.3. PRODUCT SPECIFICATIONS...............................................................................................................4
2. PRODUCT APPEARANCE AND SIGNAL CONNECTION .................................................................5
2.1. PRODUCT APPEARANCE ..................................................................................................................5
2.2. SIGNAL CONNECTION .....................................................................................................................6
3. INSTALLATION AND TESTING ....................................................................................................7
3.1. DRIVER INSTALLATION ....................................................................................................................7
3.2. SOFTWARE INSTALLATION................................................................................................................8
3.3. VOLTAGE SIGNAL TEST ....................................................................................................................8
3.4. TEMPERATURE SIGNAL TEST...........................................................................................................11
3.5. DATA FILE DETAIL.........................................................................................................................14
4. PROGRAMMING GUIDE .........................................................................................................15
4.1. OVERVIEW.................................................................................................................................15
4.2. GENERAL COMMANDS .................................................................................................................15
4.3. SETTING COMMANDS...................................................................................................................15
4.4. MEASUREMENT COMMANDS.........................................................................................................16
5. ORDERING INFORMATION .....................................................................................................17
6. SERVICE AND WARRANTY ......................................................................................................18
7. REVISION HISTORY.................................................................................................................19

3
1. Product Overview
1.1. General introduction
Smacq PS-2000 Series data collector is a compact, fully isolated multi-channel testing device
with up to four and a half readings to ensure the accuracy of test data. It is ideal for design
verification, automatic test and data acquisition, aging monitoring and many other test and
measurement applications.
Only one PS-2000 series data collector is needed to start multi-channel test tasks, scaling up
to 500 channels. It can help you start test tasks at very low cost and complete the task with very
high efficiency.
1.2. Product features
up to 4 ½ digit reading resolution,and 0.015% DC voltage accuracy
Max 200V DC voltage range
DC voltage measurement 16 channel full differential input
Only 1 module is needed to start multi-channel testing tasks, with 500-channel
scalability.
Optical isolation between measurement input and computer port
Flexible configuration system. The switch unit can collaborate with third-party test
equipment to set up test system.
SCPI instruction, Visual Studio, LabVIEW and MATLAB development support, convenient
for independent development of automated test system.
USB or RS-485 interface optional

4
1.3. Product specifications
The following specification parameters, if not specified otherwise, were tested after running the
device for 30 minutes under the temperature of 25 degree Celsius and the relative humidity of
40%.
Diagram 1、Product specifications
Model
PS2016V
PS2016V-485
PS2016I
PS2016I-485
Parameters
Voltage, Temperature(Thermocouple)
Current
Resolution
4½ - Digit
Basic accuracy
±(% reading + digits)
Voltage:0.02%+4
0.05%+4
Temperature
(Thermocouple)
K
±2℃
J
±2℃
R
±3℃
S
±3℃
E
±2℃
T
±2℃
N
±2℃
Range
Voltage:20V,200V
100mA
Temperature
(Thermocouple)
K
-50~1200℃
J
-50~910℃
R
0~1750℃
S
0~1750℃
E
-50~670℃
T
-100~400℃
N
-50~1300℃
Resolution
20V range:1mV
200V range:10mV
Temperature:0.1℃
10uA
Input resistance
1MΩ
20Ω
Sampling rate
2.5Sa/s

5
Channel
16
Channel type
2 line differential input
Channel isolation
>10GΩ
Relay pull time
6ms
Relay release time
4ms
Relay life expectancy
Mechanical 100,000,000 cycles;Electrical 500,000 cycles (full load)
Connection method
Bundled screw terminals
Control method
SCPI instruction
Communication
interface
USB
RS-485
USB
RS-485
PSU(Built-in
self-healing fuse)
USB power
5VDC
USB power
5VDC
Power consumption
5VDC,<150mA
Dimensions
Refer to chapter 2.1 dimensions diagram
Weight
Without screw terminals:500g
With screw terminals:525g
Working
environment
Temperature: 0°C to +50°C
Relative humidity: 5% to 80% (No condensation)
Storage
requirements
Temperature: –20°C to 80°C
Relative humidity: 5% to 90% (No condensation)
Calibration cycle
1 year
2. Product Appearance and Signal Connection
2.1. Product appearance
PS-2000 series DAQ device utilizes metal shield case. It uses plug-in screw terminal connectors to
connect signals. The USB communication interface uses Type-B USB connector. Figure 1 shows its
appearance. The dimensions inside the figure are millimeter.

6
2.2. Signal connection
The screw terminal connector in front of the DAQ device is for connecting the measured
signals.
On the back of the DAQ device, there are two groups of connectors, one USB interface for
connecting with computers directly; the other RS485 interface for connection with computers or
embedded processing system like PLC.
Figure 2 and Diagram 2 show its pin distribution and the corresponding signal in detail.
Diagram 2、Screw terminal connector corresponding signals
Name
Notes
ch+
ch0+ to ch15+ is the signal positive input of channel 0 to 15
ch-
ch0- to ch15- is the signal negative input of channel 0 to 15
5VDC
5VDC power input of RS-485 interface
GND
Power ground of RS-485 interface
A+
Positive input of RS-485 communication signal
B-
Negative input of RS-485 communication signal
Attention:For models with USB interface, there is no need of extra 5VDC power supply.
Figure 2、Screw terminal connector pin detail

7
3. Installation and Testing
3.1. Driver installation
When PS2016 DAQ device is connected to computers running Microsoft Windows for the first
time, it will require installing the driver before the computer can recognize PS2016 correctly.
Open the folder of "\PS Series DAQ/driver" on the Resources CD, double click the file
"SETUP.EXE", then click "Install", and there will be a dialog of success after the driver is installed.
After correctly installing the driver, Windows Device Manager will recognize PS2016 as a virtual
serial port device under the name of "USB-SERIAL CH341A". The OS will assign a serial port
number for the device as shown in parentheses in Figure 3.
Figure 3、The Device Manager with correctly recognized PS2016

8
3.2. Software installation
Open the folder "\PS Series DAQ\PS2016 - DAQ Lite Setup\Volume" and run the file "setup.exe".
Set the installation directory for the software, click "Next" all the way till it's installed. Usually you
can keep the default installation directory. Start the software after the installation. Figure 4
shows the software interface.
3.3. Voltage signal test
Connect a voltage signal of a known voltage to the PS2016 data collector, as shown in Figure
5.
Figure 4、PS2016-DAQ Lite software interface

9
Make corresponding settings on PS2016-DAQ Lite, as shown in Figure 6, with detailed notes
below.
1:Select the correct serial port connection.
2:Set the sampling cycle in seconds.
3:Set the range. Can be set as 20V or 200V range when measuring voltage signals.
4:Set the path of data storage.
5:Choose the channel to run the DAQ device in.
Figure 5、Voltage signal test connection
Attention :When measuring voltage signals, if the thermocouple range is
selected by mistake, the PS2016 DAQ device may be damaged after it runs.

10
Within the data acquisition interface after finishing the settings, click "START" button to
begin the data acquisition and real-time data storage, as showed in Figure 7, with detailed notes
below.
1: Start/Stop button
2: Real time value display.
3: Trend graph display.
4: Corresponding channel legend display.
In the trend graph display, the ordinate scale value is automatically scaled by default. You
can cancel the "automatic Y scale adjustment" by right-clicking the pop-up menu on the ordinate
scale, so as to achieve fixed vertical coordinates. After fixing the ordinate, you can double-click
the ordinate number to modify the ordinate scale value.
The same method can be used to modify the coordinate scale value.
Figure 6、Voltage testing settings