SMART-AVI SM-RS232 Manuale utente

www.smartavi.com
Installation
Manual
Control up to 16 RS232 compliant devices
up to 50 feet away over UTP
or from anywhere via TCP/IP (optional)
SM-RS232
16-Port RS232 Router
with optional TCP/IP control

2www.smartavi.com
What’s in the Box?
PART NO. QTY DESCRIPTION
SM-RS232 1 SM-RS232 16-Port RS232 Router.
PS5VDC2A 1 Power Supply 5 Volts DC 2 Amps.
SM-RS232 Front
SM-RS232 Rear
Technical Specications
RS232
Input Interface (1) DB9 Female
Output Interface (16) RJ45 Female
Pinouts TXD, RXD, GND Only, No Handshake
Control Via Software @ 9600 bps
OTHER
Power External 100-240 VAC/5VDC2A @10W
Dimensions 17”W x 6”D x 1.75”H
Weight 5 lbs.
Approvals UL, CE, ROHS Compliant
Operating Temp. 32-131°F (0-55 °C)
Storage Temp. -4-185 °F (-20-85 °C)
Humidity Up to 95%

3
www.smartavi.com
Introduction
The SM-RS232 is a 1U rack-mountable RS232 router capable of
controlling up to 16 remote RS232 compliant devices from 50 feet
away. Using seamless RS232 switching, one PC can be used to
control up to 16 devices. The SM-RS232 is perfect for controlling
the functions of multiple RS232 devices such as TVs, A/V Routers,
Signage Players, DVRs, PCs, network hubs and many other devices.
Features
• 16 RS-232 DB9 female slave ports
• Automatic transmit and receive control
• Uses standard CAT5/5e/6 cabling with compact RJ45 to DB9
adapters
• Network up to 16 RS-232 devices up to 50 feet away
• Can be controlled remotely with optional TCP/IP controller
• Supports multiple baud rates, parity, and character length
• 1U rack mountable enclosure
Applications
• Control multiple audio and video matrixes
• Remotely control displays to save energy
• Send commands to signage players
• Consolidate home or industrial automation products
• Manage co-located servers
• Control network equipment
• Manage point-of-sale terminals

4www.smartavi.com
Installation
1. Turn o all devices.
2. Connect an RS-232 cable from the console computer to the SM-RS232.
3. Connect up to 16 RS232 compliant devices to the SM-RS232 using CAT5/5e/6 cabling with
RJ45 to DB9 adapters (not included).
4. Connect the power cord to power-on the SM-RS232.
5. Power on the devices.
Control
1. First you will need to set up the terminal
application.
APPLICATION DIAGRAM
Console
Control
SM-RS232
TCP/IP
Control
Signage
Players
Routers, Switches,
Matrixes
SMTCP-R
• Open Hyperterminal on the PC. (or use
the terminal client of your choice)
• Use the default settings to create a
connection to the device. Settings MUST
match those shown on the right.
• Be sure that Flow Control is None.
• The output of the device will be the same
as the PC.

5
www.smartavi.com
2. To select a port for control, use **P[01-16]<space>
3. Once a port is selected, the connection will be transparent for sending commands to the
device.
Computers Servers
Displays
For example, if you want to manage a device on port 6, send **P06<space>.
At this point any commands you send will transparently go to the device on port 6.
If you are using a DVSW8 for example, you would select its port and then use the standard
control commands for it.
To select a port on the DVSW8 for display, use the standard “//M”command prompt.
To select the “IN 1” port, send “//M1 [ENTER]”
To select the “IN 2” port, send “//M2 [ENTER]” etc.
At any time you can switch ports on the SM-RS232 using the **P[01-16]<space> command.

6www.smartavi.com
The SMTCP-R (optional) is an RS-232
control module that allows the SM-RS232
to control most SmartAVI switching
matrixes to be controlled remotely via
HTTP or TELNET. Manage the switching
functions of your matrixes or other devices
with ease from anywhere in the world.
TELNET access provides transparent
command control of your matrix, perfect
for use with automated third-party control
software.
Applications
• Server Collocation
• Digital Signage
• Airports
• Dealer Rooms
• Control Rooms
• Audio/Visual Presentations
• Hotels/Resorts
• KVM Switches
Features
• Supports HTTP and TELNET control
• 10/100 Ethernet Interface
• Up to 10 user-denable congurations
• Password Protected
• Up to 5 Users can Control the Matrixes
• IP Conguration via TCP/IP and RS-232
• Flexible control of several types of matrixes
Technical Specications
Power External 100-240 VAC/5VDC2A @10W
Dimensions 2.8125”W x 1”H x 3.375”D
Weight 0.5 lbs
Approvals UL, CE, ROHS Compliant
Operating Temp. 32-131°F (0-55 °C)
Storage Temp. -4-185 °F (-20-85 °C)
Humidity Up to 95%
Using the SM-RS232 with the SMTCP-R Module

7
www.smartavi.com
COMPUTER IP ROUTER SMTCP-R
RS-232
SERIAL
CAT5
CAT5
Connecting to the SMTCP-R for the rst time (with DHCP)
The rst time you connect the SMTCP-R, you will need to perform the following steps to set
the initial conguration. This includes establishing an HTTP connection and manually setting
the IP address for the SMTCP-R.
1. Power o all devices.
2. Use a female to male Straight-Through RS-232 (Serial) cable
to connect the SMTCP-R to the computer.
3. Use a CAT5 ethernet cable to connect the SMTCP-R to a TCP/
IP network via a network router or other network connection
that has DHCP enabled. If your network does not support DHCP,
please see page 11 of this manual for instructions.
4. Power on the computer and run a terminal program such as Hyperterminal to open a
serial connection to the SMTCP-R using the standard 9600 baud, 8, N, 1 conguration.
5. Power on the SMTCP-R. When powered on, it will obtain an IP address automatically via
DHCP from the network.
6. The IP information for the SMTCP-R will be displayed on the terminal screen as follows:
**************************
* SmartAVI control is UP *
* version 10.12.20#6 *
**************************
addr:192.168.1.102
Mask:255.255.255.0
gtwy:192.168.1.1
**************************
NOTE: the above IP address is for demonstration purposes only. Actual results may be dierent.
7. The IP address shown must be used to connect to the SMTCP-R via HTTP.
Controlling the SM-RS232 with the SMTCP-R module (continued)

8www.smartavi.com
8. Open a web browser and navigate to the IP address
that is indicated. You will be prompted to enter a
username and password.
9. The default login (case sensitive) is as follows:
User ID: Admin
Password: Pass
10. Once connected to the SMTCP-R, you will see the following menu of options:
11. Once you have manually assigned an IP address to the
SMTCP-R, you may disconnect the Straight-Through RS-232
(Serial) cable from the computer
12. Connect the SMTCP-R to the SM-RS232 with a Cross RS-
232 (Serial) cable.
For the initial setup, click the Network Setting button and
manually assign an IP address to the SMTCP-R. This will assure
that the SMTCP-R will always
have the same IP address. Be
sure to choose an address that
will not conict with any other
devices on the network, and
that the address is not in the
range of the DHCP server.
1. Switches
2. Network Setting
3. Device Cong
COMPUTER IP ROUTER SMTCP-R
RS-232
SERIAL
CAT5
CAT5
SM-RS232
Controlling the SM-RS232 with the SMTCP-R module (continued)

9
www.smartavi.com
Controlling the SM-RS232 with the SMTCP-R module (continued)
Switches Menu
The switches menu allows you to select the output for each port on the SM-RS232.
For example, to activate input 5 on a switch that is
on port 1 of the SM-RS232, simply select port 5 on
switch 1.
Example shown in diagram:
Switch 1 is set for input 5.
Switch 2 is set for input 5.
Switch 3 is set for input 2.
Once you have completed the Initial Setup for the SMTCP-R, you can now begin conguring
it for your devices.
Using the SMTCP-R Web Interface
Device Cong Menu
The device conguration menu allows you to select the type of
matrix you are using, specify the dimensions of the matrix and
reset the system to factory defaults.
To begin, set the type of device you are using from the drop-down
menu labeled Device Type and specify the Matrix Dimensions.
After specifying the Matrix Dimensions, press the Submit button
to make the changes.
User Administration Menu
The User Administration menu allows you
to change the user name and password for
the SMTCP-R. The default user name for the
SMTCP-R is Admin and the password is Pass.
Once you modify the login information, press
the Submit button to make the changes.

10 www.smartavi.com
Controlling the SM-RS232 with the SMTCP-R module (continued)
COMPUTER IP ROUTER SMTCP-R
RS-232
SERIAL
CAT5
CAT5
Connecting to the SMTCP-R for the rst time WITHOUT DHCP
The rst time you connect the SMTCP-R, you will need to perform the following steps to set the initial
conguration. This includes establishing an HTTP connection and manually setting the IP address for the
SMTCP-R.
1. Power o all devices.
2. Use a female to male Straight-Through RS-232 (Serial) cable to connect
the SMTCP-R to the computer.
3. Use a CAT5 ethernet cable to connect the SMTCP-R to a TCP/IP network
via a network router or other network connection.
4. Power on the computer and run a terminal program such as Hyperterminal to open a serial connection
to the SMTCP-R using the standard 9600 baud, 8, N, 1, None Flow Control conguration.
5. Power on the SMTCP-R, and wait for a command prompt to appear.
6. Press ? <enter> to show the network conguration help screen as follows:
Command:
ÉÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍ»
º Network Conguration help º
ÈÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍÍͼ
Enter a command followed by optional parameters
Commands are SET DHCP INFO RESET and QUIT/SAVE
SET command allows you to change the network conguration:
SI xxx.xxx.xxx.xxx = Set IP Address
(if IP address is not entered then DHCP is ENABLED)
SM xxx.xxx.xxx.xxx = Set IP Mask
SG xxx.xxx.xxx.xxx = Set Gateway Address
RN = Reset Network Params:
IPADDR = 192.168.0.2
IPMASK = 255.255.255.0
GATEWAY = 192.168.0.1
DHCP ON = Enable DHCP
DHCP OFF = Disable DHCP
INFO = Display network conguration
RESET = Factory reset
QUIT = Saves conguration and quits
SAVE = Same as QUITNOTE: the above IP address is for demonstration purposes only.
Actual results may be different.
7. Follow the menu options to manually assign an IP address to the SMTCP-R, then refer to
page 8 for instructions to connect via HTTP.
Indice
Altri manuali SMART-AVI Router di rete

SMART-AVI
SMART-AVI HDR-UltraS Manuale utente

SMART-AVI
SMART-AVI AV Router Manuale utente

SMART-AVI
SMART-AVI HDMI4X4 Manuale utente

SMART-AVI
SMART-AVI HDC-MXS Manuale utente

SMART-AVI
SMART-AVI HDTV Router Manuale utente

SMART-AVI
SMART-AVI DVI Router 4x4 Manuale utente

SMART-AVI
SMART-AVI AVRouter 8x8 Manuale utente

SMART-AVI
SMART-AVI AVRouter AV08X08 Manuale

SMART-AVI
SMART-AVI DVR8X8 Manuale utente
Manuali Router di rete popolari di altre marche

NETGEAR
NETGEAR FS526T - Switch Manuale utente

Korenix
Korenix JetNet 5710G Series Manuale utente

Automated Logic
Automated Logic ZN551 Manuale del proprietario

Cisco
Cisco ASR 1000 Series Manuale dell'operatore

EnGenius
EnGenius ESR-9710 Manuale utente

Cisco
Cisco 805 Series Istruzioni operative e di sicurezza