System Overview
TC-8000 Master Display Unit (MDU)
Provides the following functions:
•full control from one central location on your boat
•visual indication of tank level (bar graph or lts / gals & percentage)
•visual indication of seacock position & pump status
•ability to turn holding tank macerator pump on & off manually or automatically
•ability to turn holding tank macerator pump on manually & off automatically
•all tanks are name programmable e.g. (Aft-Grey) (Port Fuel) (Aft-Fuel)
•audible alarm
•backlight
HT-100 or HB-200 or HT-100/P or HB-200/P Input/Output
Unit:
Is a controller which provides an input for the fluid level sensor. Each tank on the network
requires an IOU. The HT-100 or HB-200 allow for monitoring only while the
HT-100/P or HB-200/P provide monitoring and management of pumps connected to them.
The HT-100 or HT-100/P is to be used if using the pressure sensor.
The HB-200 is used with the ultra-sonic sensor for monitoring only.
The HB-200/P is duel purpose and used for the ultra-sonic sensor or the pressure sensor for
both monitoring and pump control.
Features include:
•teach-in level sensor with 5 point interpolation for irregular shaped tanks
•controls the pump and provides the input for the level sensor
•reversed output for tanks programmed as either fuel, enabling for fuel transfer pumps
to turn on when the tank is empty and off when full
•tank high level output which can be connected to the Aus/Sea toilet controller and will
disable the toilet when the holding tank is full
•an internal pump on/off override switch for tank servicing and cleaning
•supplied in two different models:
HT-100 or HB-200 features level sensor and tank high output
HT-100/P or HB-200/P features level sensor, tank high output, pump & electric
seacock control
RD-800 Remote Display Unit (RDU)
The RD-800 Repeater Display is an optional extra.
Any number of these may be connected throughout the vessel for convenient tank
monitoring. Note: The RDU is for monitoring only and will not allow control.