Smiths Kiosk Guida

Issue 002 - October 2018 | SmithsEP.co.uk | 1
Pedestal Range
Installation, commissioning
and user manual
Kiosk
Trafalgar
Tube
Issue 002 | October 2018
ENGLISH | UK | IRL | SmithsEP.co.uk

2 | SmithsEP.co.uk | Issue 002 - October 2018
Introduction
This product has been assembled and prepared
for easy installation.
In the event of any visible damage, please contact
us on +44 (0) 1245 324560.
Please leave this Installation and User Guide with
the owner of the property.
Contents
Introduction 2
Declaration of conformity 3
Symbols used in this guide 3
Important safety and installation instructions 4
Application 5
Product Information 5
Installation - Kiosk and Trafalgar 6
Commissioning - Kiosk and Trafalgar 7
Installation - Tube 8
Commissioning - Tube 11
Fault nding 12
User Manual
Important safety guidance 14
Introduction 15
Operation 15
Fault nding 16
Registering your product 17
Disposal 17
After sales and spares 17

Issue 002 - October 2018 | SmithsEP.co.uk | 3
Declaration of conformity
EC Declaration of conformity
We, Smith’s Environmental Products Limited
1-2 Blackall Industrial Estate
South Woodham Ferrers
Chelmsford
Essex CM3 5UW
Tel: 01245 324900 Fax: 01245 324422
Declare under sole responsibility that the products:
Product name:
Natural Convectors
Product range:
Pedestal: Kiosk, Trafalgar and Tube
Conform to the following European Union
directives and harmonised standards:
EN 442-2-2014
EN 442-1-2014 Clause 5.3
Construction Products Regulation No.
3052011
This Declaration is made on behalf of Smith’s
Environmental Products Limited by:
Gary Haynes
Chief Executive Ofcer
Date 08.09.17
Symbols
This manual contains information and
prescriptions marked by the following symbols.
Ignoring these safety provisions
marked by the symbol “caution:
hazard” may endanger the safety
of people.
The removal of the screws can
cause the output of hot uids
under high pressure from heating
system. Drain the system or close
the isolating valves.
High temperature surface. Take
utmost care to prevent people
from getting in contact with the
hot surfaces of the appliance.

4 | SmithsEP.co.uk | Issue 002 - October 2018
Important safety and installation instructions
Prior to installation, read these installation and operating instructions. The installation and operation should
also be in accordance with national regulations and accepted codes of good practice.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play
with the appliance.
To guard against injury, basic safety precautions should be observed, including the
following:
1. Read and follow all safety instructions and all the important notices on the appliance
before installing, using and maintaining the appliance. Failure to do so may cause
personal injury or damage to the appliance or installation.
2. Risk of scalding. To avoid injury before any servicing operation wait until the water has
cooled inside the appliance. Do not touch the uid or the appliance when temperature
is higher than 60°C.
3. Improper use.
This is an appliance to be used in heating systems with clean water without
abrasive particles.
4. Installation.
The appliance must be mounted in a stable/xed position in a dry, frost-free and
waterproof place, with sufcient ventilation around it. Make sure that the appliance is
securely and correctly installed before operating it and that there is enough room
around it for maintenance operations, dismantling, checking for free inspection.
Non-observance of the safety instructions results in the loss of any claims to damages.
The indicated limit values are binding and cannot be exceeded for any reason whatsoever.
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Issue 002 - October 2018 | SmithsEP.co.uk | 5
Application
Kiosk, Trafalgar and Tube are primarily
intended for installation at oor level against
a wall or window.
Tube may be installed in any orientation on the
oor or against the wall. Natural convectors can
help reduce condensation on oor to ceiling glass
when position in front of them, providing a
consistent blanket of warm exiting air from
the emitter.
These products are designed for use on standard
two-pipe pumped central heating systems.
Pipe connections are 15mm and may be
used as either ow or return. TRV should be at
Flow end. This product is not suitable for
one-pipe systems.
The heater must be installed In line with best
plumbing practices and with reference to industry
standards, such as the CIBSE Domestic Heating
Design Guide. Isolating valves (as supplied) must
be tted to system ow and return connections.
Failure to t isolating valves may mean that the
product is not serviceable in the event of failure.
Wall mounted - horizontal
Except Tube
Floor mounted
Inverted mounted
Wall mounted - vertical
Tube can be installed in the
vertical plane, but the TRV
should be at low level.
Î
Î
Î
P
Product mounting options
Product performance
Heat output
150
200
Model A
Tube .5m 500
Tube 1m 1000
Tube 1.5m 1500
Tube 2m 2000
A
Product
length
∆T °C
20 ∆T 30 ∆T 40 ∆T 50 ∆T 60 ∆T 70 ∆T
Kiosk
0.5m 22 39 60 83 109 136
1.0m 73 133 202 281 367 459
1.5m 125 226 345 479 626 783
2.0m 176 320 487 677 884 1106
Trafalgar
0.5m 39 72 110 154 201 253
1.0m 133 243 373 519 681 856
1.5m 226 414 635 885 1160 1459
2.0m 320 585 898 1250 1640 2062
Tube
0.5m 36 64 96 132 170 212
1.0m 88 157 237 325 421 524
1.5m 141 251 378 519 671 836
2.0m 193 344 519 712 922 1148
Entering ambient air temperature of 20°C
Outputs in Watts. In accordance with EN442 - BSRIA veried
210
A
92
Model A
Kiosk .5m 500
Kiosk 1m 1000
Kiosk 1.5m 1500
Kiosk 2m 2000
206
A
180
Model A
Trafalgar .5m 500
Trafalgar 1m 1000
Trafalgar 1.5m 1500
Trafalgar 2m 2000

6 | SmithsEP.co.uk | Issue 002 - October 2018
1. Remove product
from packaging
2. Remove x 2 screws from each
end of the casing
3. Slide the casing up from
the chassis
4. Position heater in
required location
Please note:
When installing a thermostatic radiator valve the
following aspects must be considered to ensure that
the valve performs to its optimum level.
1. The valve should be in a position where it is in
contact with free air circulation within the area
and is not subject to draughts as this will effect
the valve’s performance
2. The valve must not be installed in a position
where the head is likely to be damaged or
where the valve is subject to excessive heat,
either at time of installation or in
operating conditions
3. Ensure that the system is clean and free from
debris and the installation is in accordance with
good plumbing practices
5. Unscrew both end panels
to access Flow and Return
pipe unions
Installation - Kiosk & Trafalgar
➀Heat Exchanger
➁TRV (Thermostatic Radiator Valve)
➂LSV (Lockshield Valve)
➃End Panels
➄Bleed valve
➀
➁
➂
➃
➃
➄

Issue 002 - October 2018 | SmithsEP.co.uk | 7
8. Secure product to the oor
9. Commissioning
• Align the TRV head over the valve body with
the indicator point at setting V. Ensure that the
TRV head is square to the body, screw the TRV
head onto the body in a clockwise direction
until tight, being careful not to over – tighten
the head on the body
• Turn on the heating system
• Fully open Thermostatic Radiator Valve (in the
system ow) to Setting V while leaving the Lock
Shield Valve (in the system return) totally closed
• Allow the system to ll the heat emitter
• Open the air vent situated on the heat
exchanger
• Once the heat emitter is free of air, close
the air vent
• Open Lock Shield Valve and allow the heating
system to run for minimum of 1 hour
• After minimum 1-hour period, the heating
system may require further bleeding.
Follow best practices when purging the heating
system of air
Note: It may be necessary to balance the heating
system to achieve best ow and/or water
temperature.
10. Re-t casing
6. Prepare ow/return connection
and connect to heating system
using suitable ttings
• Pipe connection is 15mm
• Flow connection should be TRV End
• Isolating valves must be tted to ow and
return pipework for servicing
7. Ret end panels
Commissioning
All factory tted connections/compression joints
should be inspected prior to lling the system, in
case of loosening during transit

8 | SmithsEP.co.uk | Issue 002 - October 2018
1. Remove product
from packaging
2. Remove x 2 screws from inside
legs of the product to release the
end trim
4. TRV and Lockshield valves are
pre-tted to the heat exchanger
Installation - Tube
Standalone:
Tube is designed to be installed as standalone
heat emitters.
Each unit stands on its own with pipework being
made through the feet in each end of the product.
The heat-exchanger within the products casing is
factory tted with TRV & LSV.
3. Slide the end trim away from
product casing
0.5m 1.0m 2.0m
1.5m
Product lengths/sections in products

Issue 002 - October 2018 | SmithsEP.co.uk | 9
6. Prep ow and return
connections and ready system
pipework for connection
Check connection is good and undamaged
from transit.
7. Fix both ends to the oor
using suitable xings
8. Connect system pipework to
the TRV and Lockshield valves of
each end of the product
5. Position heater where required
Pipe entry is through ooring surface.

10 | SmithsEP.co.uk | Issue 002 - October 2018
12. Screw the TRV onto
the product
11. Ensure that the TRV is set on
the V position
10. Ret retaining screws to x
the end panels
9. Ret end trims
Installation - Tube
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Smiths Stufa
Manuali Stufa popolari di altre marche

Empire Heating Systems
Empire Heating Systems WCC65 Manuale utente

Wetekom
Wetekom 92 86 43 Manuale utente

Desa
Desa SPC170-F Manuale utente

Watlow
Watlow Watrod Electric Tubular Heaters Manuale utente

Haverland
Haverland ECO-DRY GPS Series Manuale elenco delle parti

Stelpro
Stelpro ASILVC2060 Series Manuale utente