socomec DATALOG H80 Manuale utente

DATALOG H80/H81
for collecting energy data
EN
InstructIon
manual
http://www.socomec.
com/datalogger

2EN DATALOGGER H80-81 - 546226A - SOCOMEC
GB CONTENTS:
1. Table of conTenTs
1. DOCUMENTATION .............................................................3
2. PRELIMINARY OPERATIONS....................................................3
3. INTRODUCTION ...............................................................3
3.1. General presentation .................................................3
3.2. Communication architecture ...........................................5
3.3. Data file.............................................................6
3.4. Configuration of 3G communication of DATALOG H81 ....................7
3.5. Access the configuration of DATALOG H80/H81 .........................9
4. CONFIGURATION .............................................................10
4.1. Identification........................................................10
4.2. Configuration home page ............................................11
4.3. Declare devices .....................................................12
4.3.1. Management of communication gateways .....................12
4.3.2. Adding devices to DATALOG H80/H81: .......................13
4.3.3. Auto discovery of devices ..................................13
4.3.4. Add a device..............................................14
4.4. Declare data........................................................17
4.4.1. Data configuration page ....................................17
4.4.2. Selection of variables for the device concerned ................18
4.4.3. Setting the properties of the variables (for the following types:
Measuring, Meter/Index)..........................................18
4.4.4.
Setting the properties of the variables (for the following types: Status)... 19
4.4.5. Setting the properties of the variables (for the following types: Alarm).... 20
4.5. Configure the data logger ............................................21
4.5.1. “System” tab..............................................21
4.5.2. “Publish data” tab .........................................22
4.6. Configure the activity report ..........................................22
4.7. Options ............................................................24

3
EN
DATALOGGER H80-81 - 546226A - SOCOMEC
1. DocumenTaTion
All documentation on the DATALOG H80/H81 is available on the
SOCOMEC website at the following address:
http://www.socomec.com/datalogger-documentation
2. Preliminary oPeraTions
It is highly recommended to become thoroughly acquainted with the contents of this manual before conguring and
using DATALOG H80/H81.
To install and connect DATALOG H80/H81, a Quick Start guide is delivered with the device. It is also available at the
following address: Http://www.socomec.com/datalogger-documentation
DATALOG H80/H81 can be congured by connecting:
• directly to DATALOG H80/H81 via the available interfaces (HDMI interfaces, USB 2.0 and USB 3.0). User can
directly connect their devices (screen, keyboard, mouse), as indicated in the Quick Start guide,
• to the web server of DATALOG H80/H81, via the browser on a workstation connected to the network.
Here is the list of compatible browsers:
• Internet Explorer v9 and higher
• Firefox v24 and higher
• Chrome v30 and higher
We recommend the use of a screen with 1280 x 900 pixel format.
3. inTroDucTion
3.1. General presentation
DATALOG H80/H81 is part of the range of communication gateways proposed by Socomec.
DATALOG H80/H81, installed at the heart of the energy ecosystem, allows you to:
• automatically collect energy data from meters and multi-uid measuring stations;
• pool, secure and store energy data;
• publish data to a system or an external application.

4EN DATALOGGER H80-81 - 546226A - SOCOMEC
The following diagram summarises the major functions of DATALOG H80/H81
DATALOG H80/H81 is available in 2 versions:
• DATALOG H80: 4 LAN Ethernet ports
• DATALOG H81: 4 LAN Ethernet ports + 1 wireless 3G port (for publishing data)
Detailed description of the H80:
Mini Fanless Industrial PC, Intel Atom CPU with dual core N2807 1.58 GHz processor, CFAST slot, 1 x RS232, 1
x USB3.0, 2 x USB2.0, HDMI output, 2 x GbeLAN, Vin +12 VSC (lockable plug). Supplied with AC/DC adaptor for
Europe.
Includes:
• RAM 4GB DDR3L
• FLASH CFAST 32 GB MLC type Top -40° to 85°C card
• LICENCE and OS MICROSOFT WES7 installed
• RAILDIN 9741640401 mount
The DATALOG H80 is guaranteed for 1 year.
Detailed description of the H81:
Mini Fanless Industrial PC, Intel Atom CPU with dual core N2807 1.58 GHz processor, CFAST slot, 1 x RS232, 1
x USB3.0, 2 x USB2.0, HDMI output, 2 x GbeLAN, Vin +12 VSC (lockable plug). Supplied with AC/DC adaptor for
Europe.
Includes:
• RAM 4GB DDR3L
• FLASH CFAST 32 GB MLC type Top -40° to 85°C card
• LICENCE and OS MICROSOFT WES7 installed
• RAILDIN 9741640401 mount
• 3G modem with antenna installed.
The DATALOG H81 is guaranteed for 1 year.

5
EN
DATALOGGER H80-81 - 546226A - SOCOMEC
3.2. Communication architecture
DATALOG H80/H81 is interconnected with various external devices for the operation of certain services:
• FTP / HTTP servers for the publication of data stored in DATALOG H80/H81 and the backup of alarm and log
les, as well as a conguration backup
• SMTP server: for sending activity reports by e-mail
The diagram below shows the standard communication architecture:

6EN DATALOGGER H80-81 - 546226A - SOCOMEC
3.3. Data le
Example of the le activity reports from DATALOG H80/H81 to the FTP / HTTP server:
Data Type,"TimeZone","Datation","Transfert Cycle (sec)","Polling Time","Version","Site Id","Gateway Id"
Measure,"Europe/Paris","Local","300","N/A","1.0","Benfeld","U1"
Index Key,"Key","Type","Name","Fluid","Use","Coef","Unit","Path","Device Id","Index","Data Id"
0,"Benfeld|U1|5|1|ANA|10002|0","ANA","CLIM local therm - Gateway - 172.23.24.100 - Current L3","None","None",1,"A"," / ","5","1","10002"
1,"Benfeld|U1|5|1|ANA|10001|0","ANA","CLIM local therm - Gateway - 172.23.24.100 - Current L2","None","None",1,"A"," / ","5","1","10001"
2,"Benfeld|U1|5|1|ANA|10000|0","ANA","CLIM local therm - Gateway - 172.23.24.100 - Current L1","None","None",1,"A"," / ","5","1","10000"
3,"Benfeld|U1|5|1|ANA|110002|0","ANA","CLIM local therm - Gateway - 172.23.24.100 - Voltage L3","None","None",1,"V"," / ","5","1","110002"
4,"Benfeld|U1|5|1|ANA|110001|0","ANA","CLIM local therm - Gateway - 172.23.24.100 - Voltage L2","None","None",1,"V"," / ","5","1","110001"
5,"Benfeld|U1|5|1|ANA|110000|0","ANA","CLIM local therm - Gateway - 172.23.24.100 - Voltage L1","None","None",1,"V"," / ","5","1","110000"
Index Key,"Date","Value","Quality"
0,2017-01-19T15:40:42,3.039,192
1,2017-01-19T15:40:42,3.169,192
2,2017-01-19T15:40:42,2.403,192
3,2017-01-19T15:40:42,232.1,192
4,2017-01-19T15:40:42,232.81,192
5,2017-01-19T15:40:42,232.13,192
0,2017-01-19T15:41:42,3.036,192
1,2017-01-19T15:41:42,3.256,192
2,2017-01-19T15:41:42,2.441,192
3,2017-01-19T15:41:42,231.77,192
4,2017-01-19T15:41:42,233.14,192
5,2017-01-19T15:41:42,231.73,192
0,2017-01-19T15:42:42,3.112,192
1,2017-01-19T15:42:42,3.201,192
2,2017-01-19T15:42:42,2.392,192
3,2017-01-19T15:42:42,231.96,192
4,2017-01-19T15:42:42,232.39,192
5,2017-01-19T15:42:42,231.94,192
0,2017-01-19T15:43:42,2.938,192
1,2017-01-19T15:43:42,3.199,192
2,2017-01-19T15:43:42,2.307,192
3,2017-01-19T15:43:42,231.54,192
4,2017-01-19T15:43:42,232.12,192
5,2017-01-19T15:43:42,231.47,192
0,2017-01-19T15:44:42,5.267,192
1,2017-01-19T15:44:42,5.214,192
2,2017-01-19T15:44:42,4.76,192
3,2017-01-19T15:44:42,232.2,192
4,2017-01-19T15:44:42,232.84,192
5,2017-01-19T15:44:42,231.69,192

7
EN
DATALOGGER H80-81 - 546226A - SOCOMEC
3.4. Conguration of 3G communication of DATALOG H81
If a 3G connection is used, the user will need to congure the Windows services of DATALOG H81 so that the
connection can be activated automatically.
To access the conguration menu of the Windows services, the user can use the script “Remote Desktop
Connection”.
- Access the “MSTSC.exe” script on your computer
- Enter the URL of DATALOG H81
- Use the Windows account
Account: .\admin
Password: To nd out the password, contact your advisor at Socomec.
Once connected to DATALOG H81:
- Access the “Control Panel” section in the Start menu.

8EN DATALOGGER H80-81 - 546226A - SOCOMEC
- Then access the “Administrative Tools” section
- Then access “Services”
- Finally access the “Socomec Network Connection Service”

9
EN
DATALOGGER H80-81 - 546226A - SOCOMEC
Set the “Start-up type” in the General menu to “Automatic”
3.5. Access the conguration of DATALOG H80/H81
To access the conguration of DATALOG H80/H81, the user has several ways:
1. By directly connecting a keyboard and screen to DATALOG H80/H81, then by clicking on the icon
2. By accessing the “Remote Desktop Connection” script (see Chapter 3.5), and then clicking on the icon
3. Via a web browser: enter the URL of DATALOG H80/H81

10 EN DATALOGGER H80-81 - 546226A - SOCOMEC
4. confiGuraTion
DATALOG H80/81 must be congured so the different functions of collecting, storing and publishing data can be
used.
Below are the details of the various possible conguration options.
4.1. Identication
To accessing the conguration interface, the user requires a password.
To nd out the password, contact your advisor at Socomec.
Altri manuali per DATALOG H80
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali socomec Registratore di dati