Sollae SIG-5451 Manuale utente

SIG-5451 User Manual Ver. 1.0
- 1 -
https://www.ezTCP.com
This symbol, found on your product or on its packaging, indicates that
this product should not be treated as household waste when you wish to
dispose of it. Instead, it should be handed over to an applicable collection
point for the recycling of electrical and electronic equipment. By ensuring
this product is disposed of correctly, you will help prevent potential negative
consequences to the environment and human health, which could otherwise be caused by
inappropriate disposal of this product. The recycling of materials will help to conserve
natural resources. For more detailed information about the recycling of this product,
please contact your local city office, household waste disposal service or the retail
store where you purchased this product.

SIG-5451 User Manual Ver. 1.0
- 2 -
https://www.ezTCP.com
Contents
1Overview .......................................................- 4 -
1.1 Introduction ........................................................ - 4 -
1.2 Features ............................................................ - 4 -
1.3 Specification ....................................................... - 5 -
1.4 Interface ........................................................... - 6 -
1.4.1 Power .................................................................. - 6 -
1.4.2 Ethernet ............................................................... - 7 -
1.4.3 Digital Output Port .................................................... - 7 -
1.4.4 LED .................................................................... - 8 -
1.4.5 Function Button ........................................................ - 9 -
1.4.6 Setup Port ............................................................. - 9 -
2Preparation ...................................................- 10 -
2.1 Installing the Setting Tool ........................................ - 10 -
2.2 Connecting a Product ............................................... - 10 -
2.3 Searching Devices .................................................. - 10 -
2.4 Logging in ......................................................... - 10 -
3Settings ......................................................- 11 -
3.1 Network ............................................................ - 11 -
3.1.1 Obtain an IP address automatically..................................... - 11 -
3.1.2 Use a Static IP address................................................ - 12 -
3.2 General ............................................................ - 13 -
3.2.1 Comment ............................................................... - 13 -
3.2.2 Digital Output ........................................................ - 13 -
3.3 Security ........................................................... - 14 -
3.3.1 Password .............................................................. - 14 -
3.3.2 Certificate ........................................................... - 14 -
3.3.3 spFinder .............................................................. - 14 -
3.3.4 Client ID ............................................................. - 15 -
4Management ....................................................- 16 -
4.1 Checking Status .................................................... - 16 -
4.1.1 Product Information ................................................... - 16 -
4.1.2 Communication Status .................................................. - 17 -
4.1.3 Timeout ............................................................... - 18 -
4.1.4 Copy status ........................................................... - 18 -
4.2 Firmware Change .................................................... - 19 -
4.2.1 Online Upgrade ........................................................ - 19 -
4.2.2 Manual Upgrade ........................................................ - 20 -
4.2.3 Remote Upgrade via cloud............................................... - 20 -
4.3 Console ............................................................ - 21 -

SIG-5451 User Manual Ver. 1.0
- 3 -
https://www.ezTCP.com
4.3.1 Output Tab ............................................................ - 21 -
4.3.2 FW Log Tab ............................................................ - 22 -
4.3.3 Timeout ............................................................... - 22 -
4.4 Export/Import Setting Values ....................................... - 23 -
4.5 Factory Reset ...................................................... - 24 -
5Technical Support and Warranty ................................- 25 -
5.1 Technical Support .................................................. - 25 -
5.2 Warranty ........................................................... - 25 -
5.2.1 Free Repair Services .................................................. - 25 -
5.2.2 Charged Repair Services................................................ - 25 -
6Precaution and Exemption from Liability .......................- 26 -
6.1 Precaution ......................................................... - 26 -
6.2 Exemption from Liability ........................................... - 27 -
6.2.1 English version ....................................................... - 27 -
6.2.2 French version ........................................................ - 28 -
7Revision History ..............................................- 30 -

SIG-5451 User Manual Ver. 1.0
- 4 -
https://www.ezTCP.com
1 Overview
1.1 Introduction
SIG-5451 is an industrial I/O Gateway connected to Sollae Cloud. It is equipped
with 2 digital output ports and an Ethernet interface. Users can use this product to
control remote devices by using a web browser on your PC, tablet or smartphone.
This document presents the information related to device only. To connect the
device to Sollae Cloud, see Sollae Cloud User Guide.
1.2 Features
⚫2 digital output ports (Relay): Both NO and NC output
⚫Ethernet Interface
⚫Freely connected to Sollae Cloud via MQTT
⚫Data is encrypted and securely transmit using TLS 1.2
⚫Client certificate authentication for devices
⚫Industrial temperature range (-40℃ ~ +85℃)

SIG-5451 User Manual Ver. 1.0
- 5 -
https://www.ezTCP.com
1.3 Specification
Digital Output
Output Type
Relay (Type C - NO/NC, Max DC 30V/2A with resistive load)
Number of Ports
2 ports
Network Physical Interface
Network Interface
10Base-T/100Base-TX Ethernet (RJ45)
Ethernet Speed Auto Sense
1:1 or Cross-over Cable Auto Sense
Software Functions
Protocols
IP, TCP, ICMP, DHCP, mDNS, MQTT, SSL/TLS 1.2
Network Security
Client certificate-based mutual authentication over TLS
1.2
Indicators
LED
PWR, STS, MTX, MRX, Do0, Do1
Management
spFinder
Configuration and Monitoring Tool
Access Security
Password
Dimension
Size
94mm x 57mm x 23mm
Weight
about 68g
Operating Environment
Input Voltage
DC5V±0.5V
Protection
Reverse Voltage Protection / Surge Protection
Current Consumption
typically, 210mA
Operating Temperature
-40℃ ~ +85℃
Storage Temperature
-40℃ ~ +85℃
Certificate
KC
Registration (KN 32, KN 35)
CE
EMC 2014/30/EU, RoHS 2011/65/EU
FCC
FCC Part 15 Subpart B, Class A
Table 1-1 Specification

SIG-5451 User Manual Ver. 1.0
- 7 -
https://www.ezTCP.com
1.4.2 Ethernet
SIG-5451 provides 10/100Mbps Ethernet. The pin assignment is as follows:
Figure 1-3 Ethernet
1.4.3 Digital Output Port
This port is interfaced with a 3.5mm pitch 6-pole terminal block.
Figure 1-4 Digital output port
⚫Port Specification
Division
Value
Number of ports
2
Max. Allowed Current
at DC 30V
Normal Open
5A
Normal Close
1A
Table 1-2 Port Specification
The port specifications are for resistive loads. For capacitive loads such as
SMPS and inductive loads such as motors, the current under normal operation
should be about 10 ~ 20% of the maximum allowed current.
⚫Port Specification
State
NO Operation
NC Operation
LOW
NOT Connected to C0/C1
Connected to C0/C1
HIGH
Connected to C0/C1
NOT Connected to C0/C1
Table 1-3 Port Operation

SIG-5451 User Manual Ver. 1.0
- 8 -
https://www.ezTCP.com
1.4.4 LED
SIG-5451 provides 8 LEDs.
Figure 1-5 4 LED operations according to each state are as follows:
When the supplied power is stable: PWR
When the supplied power is NOT stable: PWR
When the script is running: RUN
When the script is running: RUN
When a network is not connected: LINK
When a network is connected: LINK
When a MQTT connection is NOT established: MTX & MRX
When sending data to the cloud: MTX
When receiving data (command) from cloud: MRX
When the output port is LOW: Do0 & Do1
When the output port is HIGH: Do0 & Do1
Indice
Altri manuali Sollae Portale
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente