Solutions VT1007 Manuale tecnico

Talking Thermostat
Key Information
Guide
Models
VT1007, VT2007 & VT2207


Talking Thermostat
Key Information Guide
Models VT1007, VT2007 and VT2207
TOPICS Page(s)
All Settings: Quickly Reviewing ...........................................................12
Bypass Compressor Short Cycle Protector ..........................................5
Calibrate Indoor Temperature................................................................2
Cycle Rate (Setting)...............................................................................3
Fahrenheit to Celsius (Changing to and from).......................................4
Filter, Service and UV Light Alerts –
Default Setting (Months & Optional Hours) ........................................9
Adjusting Months .............................................................................10
Changing to Hours ...........................................................................11
Adjusting Hours ...............................................................................11
Reviewing Months (or Hours) ..........................................................12
Clearing “CHK FILT” Display ............................................................13
Clearing “CFS” Service Display .......................................................13
Clearing “CFS” UV Light Display......................................................13
Resetting Filter Months or Hours (CFS Svc, CFS UVL, CHK FILT ...13
Turning Off CHK FILT Alert .................................................................9
Heat Pump
Activating Emergency Heat (“Eon”)..............................................6, 14
Reducing 2nd Stage Time Delay (“Eon”)................................6, 14, 17
Locking Out Programmable Operation .................................................7
Locking Out All Operations ...................................................................7
Model Number by Type .........................................................................1
Operation Keys (Descriptions & Functions)...........................................1
Program Keys........................................................................................6
Reset Key
Escape Program Mode..........................................................................4
Escapes Faulty Operation (FFr) .............................................................4
Service Alert – (see above Filter, Service and UV Light Alerts)
Troubleshooting Tips ...........................................................................17
Voice On/Off (Set Point Temp UP & DOWN Keys) ................................8
VT2007 2nd Stage Differential – Setting..............................................14
VT2207 2nd Stage Differential – Setting..............................................16
VT2007& VT2207: 2nd Stage Differential Table...................................15

Operation Keys and Alert Light
Model Number by Type
1
For Custom Message / Warranty Information
Press HELP
For Indoor Temperature and Set Point Temperature
(Also reports Check Filter, Low Battery and Call For Service)
Press REPORT
ALERT LIGHT – When Flashing Press REPORT Key to
hear alert message
To Raise Temperature Press UP
To Lower Temperature Press DOWN
FUNCTION Key
Press BRIEFLY to backlight display screen
Press and HOLD to hear revision number
MODEL Number
VT1007 -- Single Stage Heat / Cool
VT2007 – 2 Stage Heat / Single Stage Cool / Heat Pump
VT2207 – 2 Stage Heat / 2 Stage Cool (NOT for Heat Pumps)

Calibrate Indoor Temperature
2
Press the UP and DOWN keys together
and HOLD until INDOOR TEMPERATURE
starts to FLASH. RELEASE. Press the UP
or DOWN key to raise or lower INDOOR
TEMPERATURE to the desired setting.
When finished
press RUN.
NOTE: Indoor Temperature calibration is limited to (+ / -) 3˚ F /
2˚ C from factory default setting. Do not calibrate until unit has
run one complete cycle.

Setting Cycle Rate
3
Press the UP and DOWN keys together
and HOLD until INDOOR TEMPERATURE
starts to FLASH. RELEASE. Press BOTH
again until Cr1 appears in setpoint location.
Press UP and DOWN key to move to the
desired setting. Press Run.
Cr1 will appear here.
NOTE:
Cr1 = 1 Degree
Cr2 = 2 Degrees
Cr3 = 3 Degrees
CR1

Fahrenheit to Celsius
& Reset Key
4
To Change From Celsius to Fahrenheit,
Press and HOLD the YES and NO keys
together for 6 seconds.
Reset Key
The RESET key has two primary functions.
1. Escape Program Mode: If, during programming, you
get lost or wish to quit, press RESET. You will exit the
programming mode without making changes.
2. FFr (Escapes Faulty Operation): Static discharge
can cause faulty operation. To correct, press both
the NO and RESET buttons together until the display
disappears. When it reappears, press the RUN button
to accept the FLASHING INDOOR TEMPERATURE.

Bypass Compressor
Short Cycle Protector
5
If you turn the cooling OFF and back ON in
less than 5 minutes, the unit will activate
the time delay. COOL and DELAY will
FLASH.
Press the NO and FUNCTION keys and
HOLD for 8 seconds. This will disable
the time delay feature for 10 minutes.
COOL will stop FLASHING and DELAY
disappears.
COOL
DELAY

Program Keys
6
PROGRAM ON / OFF KEY
Press to turn program on or off.
WEEKDAY AND WEEKEND KEYS
Press and follow instructions to change program.
DAY / TIME KEY
Press and follow instructions to change the time
and day of the week.
RUN KEY
Press to advance to next step when programming.
NOTE:
On heat pump models, pressing and holding RUN
and YES will send thermostat into emergency or
reserve heat. This also reduces the Time Delay
between 1st & 2nd stage HEAT to 1 minute. To
restore the default 8-minute delay, perform an
“FFr” Reset per instructions on page 4.

Locking Out Programmed Operation
7
Locking Out All Operations
Lock out
prevents users
from accidentally
running
programmable
operation. Press
Full lock
out prevents
unauthorized
users from
making changes.
Press and hold
YES and HELP
keys until you
hear “OFF”.
and hold NO and ON/OFF keys for 6 seconds.
Audio plays “OFF” when any program button is
pressed. To unlock, repeat same.
Locks out all functions except the REPORT
and HELP keys. To unlock, repeat same until
you hear “O”.