Solutronic Energy GridManager Manuale utente

User Manual GridManager
with FEED-IN function
User manual GridManager with FEED-IN function
MoS/MM/JK 2016-11-23 Version: A8, Subject to change without prior notice

GM_User Manual_A8_EN
User Manual GridManager with FEED-IN function
2.1 Aim of this manual...............................................................................................................
2.2 Scope.................................................................................................................................
2.3 Target group...................................................................................................................
2.4 Explanation of the symbols and associated terms used............................................
2.5 Abbreviations....................................................................................................................
3.1 Safety in general..............................................................................................................
3.2 Intended use.......................................................................................................................
9.1 LED power..........................................................................................................................
9.2 LED L1, L2, L3..............................................................................................................
9.3 LED error.........................................................................................................................
11.1 IP-address GridManager..................................................................................................
11.2 Total AC power of connected inverters...........................................................................
11.3 Minimum withdrawal from grid / Maximum feed in to the grid..............................
11.4 Additional settings.............................................................................................................
12.1 Activating FEED-IN mode.................................................................................................
12.2 Assigning phases L1 L2 L3...........................................................................1.................
12.3 UDP-Port (Parameter are not active).........................................................................
12.4 Fallback.........................................................................................................1.
12.5 Using more than one GridManager................................................................................
12.6 Verifying communication...............................................................................................
Contents
Contents
3 Safety..................................................................................................................................
4 Prerequisites..............................................................................................................................
5 Mode of Operation..............................................................................................................
6 Installation GridManager 63........................................................................................................
7 Installation GridManager 250................................................................................................
8 Connecting GridManager, inverters and PC1...............................................................................
9 Operating status............................................................................................................................
10 Data connection to GridManager using SOLPLUS+...........................................................
11 Parameter settings GridManager............................................................................................
12 Parameter settings Inverter.......................................................................................................
13 Measurement readings GridManager..................................................................................
14 Attachment..............................................................................................................................
14.1 Example.........................................................................................................................
1 Notes about the User Manual...................................................................................................
2 Notes about this manual........................................................................................................
1
1
1
1
1
1
3
4
4
4
5
6
7
9
11
12
12
12
12
13
14
14
15
16
19
21
21
22
22
23
24
25
26
27
27

GM_User Manual_A8_EN 1/28
12.1 Activating FEED-IN mode.................................................................................................
12.2 Assigning phases L1 L2 L3...........................................................................1.................
12.3 UDP-Port (Parameter are not active).........................................................................
12.4 Fallback.........................................................................................................1.
12.5 Using more than one GridManager................................................................................
12.6 Verifying communication...............................................................................................
1 Notes about the User Manual
Dear Customer,
Thank you for buying a GridManager with FEED-IN function designed and manufac-
tured by Solutronic Energy. This manual describes how to use your GridManager with
FEED-IN function. Please keep it somewhere where you have ready access to it
whenever you need to. Please comply at all times with the safety precautions we refer
to in this manual. Please be advised in all cases the security precautions referred to in
this document.
2 Notes about this manual
2.1 Aim of this manual
This manual will help you to carry out installation work on your inverter quickly and
safely. Please read this chapter thoroughly and carefully. It contains some important
tips on how to use this manual.
2.2 Scope
This User Manual applies to the Solutronic GridManager with FEED-IN function.
2.3 Target group
All service work on SOLPLUS inverters must be performed by a fully qualified
electrician who has completed the technical training offered by Solutronic. The fitter
must have the necessary certification and authorisation of the responsible power
utility.
2.4 Explanation of the symbols and associated terms used
2.4.1 Explanation of the symbols used for safety instructions
Please read and observe the following safety instructions in this manual.
The danger classes describe the risks of non-observance of the safety instructions.
(The safety instructions describe the following danger classes per ANSI.)
Notes about the User Manual

GM_User Manual_A8_EN2/28
Attention!
“Attention!" denotes a warning that, if not observed, can result in property
damage!
Warning!
"Warning!" denotes a warning that, if not observed, can result in death or
serious injury!
"Danger!" denotes a warning that, if not observed, will result in death or
serious injury!
Useful information and tips to help you operate the GridManager to best
effect.
Caution!
"Caution!" denotes a warning that, if not observed, can result in personal
injury!
Danger!
Note
Description of the Nameplate
Notes about this manual

GM_User Manual_A8_EN 3/28
2.5 Abbreviations
The following abbreviations are used in this manual:
SOLPLUS+ =
=
Read-out and monitoring software for use with all Solutronic
inverters
DC Direct current (direct voltage): electrical value on the input side of
theinverter
=
=
AC
PV
Generator
Photovoltaic
=
GM GridManager with FEED-IN function
Alternating current (alternating voltage): electrical
value on the output side of the inverter
=Solar generator: interconnection of several solar modules to
form a string or a number of parallel strings
Notes about this manual

GM_User Manual_A8_EN4/28
Warning!
Improper use of these devices, non-observance of the warnings given in this
manual and improper tampering with the safety functions can lead to property
damage, personal injury, electric shock and, in extreme cases, death.
Danger!
High voltage due to incorrect connection! Risk of fatal or bodily injury from
electric shock.
3 Safety
3.1 Safety in general
Please read the following safety information and instructions before you put the
GridManager with FEED-IN function into operation for the first time, in order to avoid
personal injuries and/or property damage. These instructions must be complied with
at all times.
If you are not able to understand the language used in this documentation sufficiently,
please contact and inform the supplier of the situation.
Do not try to attempt to install or put the GridManager with FEED-IN function into
service until you have read through all the documentation supplied thoroughly.
Solutronic Energy shall accept no liability for damages resulting from non-observance
of the warnings given in this User Manual.
If you sell on, hire out or pass on this device to someone else in some other way,
make sure that you give the new user these safety instructions, too. Trouble-free and
safe operation of the GridManager with FEED-IN function presumes proper,
professional and workmanlike transportation, storage, mounting and installation as
well as careful operation and thorough maintenance.
3.2 Intended use
This device must be used only for the purpose described in this User Manual:
accessory for use in grid-connected photovoltaic installations.
All safety regulations must be complied with. All installation work must be carried out
precisely as described in this manual. No modification of any kind to or in this device
or to its external wiring is permitted. Any such modification could lead to serious
safety problems and danger to life and limb.
Safety

GM_User Manual_A8_EN 5/28
Laptop or PC death.
with SOLPLUS+
professional
GridManager 63 or
GridManager 250
Switch
SOLPLUS 25-55:
SOLPLUS 80-120:
SE 40S2-SE 60S2:
Firmware
Firmware
Firmware
Preferably one with option
to ground the shield of
cables
V2.67.2 or higher
V1.49.13 or higher
V2.2.7
Firmware V1.4.9 or higher
For setting up the
GridManager. Not required
for operation.
V 2.7.4
or higher
4 Prerequisites
The inverters and the GridManager should be connected in one Ethernet using a
dedicated switch for this setup. Using RS485 for regulation is not possible.
Abbildung Bezeichnung Beschreibung
Inverter
Inverter
Inverter
Prerequisites

GM_User Manual_A8_EN6/28
The energy provider requires a temporary power reduction of the installation:
The inverters are regulated to produce no more power than the current allowed
amount plus the current consumption.
The connected power is generally limited: The inverters are regulated to produce
no more power than the allowed amount plus the current consumption.
There is no feed in allowed / required: The inverters are regulated to produce no
more power than the current consumption minus a small margin for regulation.
5 Mode of Operation
The GridManager covers the power management of the inverter as a function of local
consumption.
It’s located between the SOLPLUS inverters and appliances; and the power meter.
The typical reaction time for power regulation is 4 Milliseconds.
If e.g. a maximum of 70% of the installed DC power may be fed in but refrigerator,
lights etc. are switched on. The consumption of these is added to the 70% and allows
the inverter to produce more power to compensate for this.
Potential uses for GridManager:
Mode of Operation

GM_User Manual_A8_EN 7/28
6 Installation GridManager 63
Connection
3x 230 Volt, N, PE, 50 Hertz, max. 63 Ampere per Phase
It shall be installed between the meter (reference counter when feed in is zero
or bidirectional meter when grid-feed is limited) and the local distribution for
appliances and PV-inverter
You may install either a GridManager or a PowerReductionCard, installing both
at the same installation will not work.
Connect appliances to the same phase as the inverter, especially if only one
inverter is used.
Installation
AC-voltage measurement and power supply
The grid voltages L1, L2 and L3 and neutral line N are connected to the green
4-pin connector at the bottom side. L3 and N (230 V AC, 50 Hz) are used to
supply the GridManager. Wire cross-section 1,5 mm².
Check for correct phasing
For overall one phase operation connect the one phase used to all 3 pins L1,
L2 and L3 of the 4-pin connector for voltage measurement. This can be
achieved by bridging all 3 pins.
For correct display of the measured voltages connect ground to the GridMan-
ager. This is best done on the shield of the Ethernet connector. However, the
GridManager will regulate fine without ground connected.
AC-current measurement
The power lines have to be separated on terminals and routed from the
bottom-up through the current transformers of the GridManager.
Wire cross-section 16 mm² (max.) for GridManager 63
Check for correct phasing
Installation GridManager 63

GM_User Manual_A8_EN8/28
L1
L2
L3
N
SLS*Z2*
*If available/required
Note
PE connections not shown!
Installation schematic
House distribution,fuses etc.
Light etc.
Appliance 1-Phase
Appliance 1-Phase
Appliance 3-Phase
Stove
one or more 1-phase
or 3-phase inverter
~
=
Z1*
Yield counter
Ethemet-connection Grid-connection
of building
Lower side: power cable input, voltage measurement and N
Upper Side: Ethernet, power cable outlet
Installation GridManager 63
power cable input
CAN cable &
ground cable
voltage
measurement
Ethernet
GM
Two-way
counter
Load
isolator
N L1 L2 L3
N L1 L2 L3
Indice