Solvera Lynx COMBOX.L Manuale utente

1
USER MANUAL
COMBOX.L
Long Range Low Power
Wireless Logger

Solvera Lynx d.d.
Stegne 23A
SI-1000 Ljubljana
T+386 1 40 12 860
F+386 1 40 12 861
Wsolvera-lynx.com
Solvera Lynx d.d. is entered in the Court at Ljubljana District | Share capital: 53.434,75 EUR | ID number: 1716808000 |VAT ID: SI98578537 | Board Chairman: dr. Otmar Zorn
Bank account: SI56 0203 6009 1956 438 at NLB d.d., SWIFT: LJBASI2X
User manual
V1.1

3
CONTENTS
1. Information about the document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.1. Document data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2. Disclaimer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.3. Technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Product presentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1. Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2. Package Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3. Highlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4. Advanced features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
2.5. ComBox.L Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3. Tehnical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
3.1. Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
4. Technical data according to type:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.1. ComBox.L CI-B type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.2. ComBox.L DI-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
4.3. ComBox.L 2T-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
5. Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.1. Notication for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.2. Hardware installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
5.3. Connection to NMS (Network Management Server) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
6. Recommended elds of use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7. Certication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.1. LoRa Certicate of Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7.2. SIQ Certicate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
8. EU Declaration of Conformity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

4
1. INFORMATION ABOUT THE DOCUMENT
Title User Manual: ComBox.L
Subtitle Long Range Low Power Wireless Logger
Document type User Manual
Version V 1.1
1.1. DOCUMENT DATA
1.2. DISCLAIMER
All rights to this manual and the information contained herein are the property of Solvera Lynx.
Reproduction, use or disclosure to third parties without expressed permission is prohibited.
Solvera Lynx reserves the right to change the technical specications of its products without notice in
writing and urges its customers to make sure that the information they have is valid.
If you have technical problems or cannot nd the required information in the provided documents,
contact our Technical Support by e-mail using our dedicated e-mail address:
[email protected]. Your request will be processed as soon as possible.
Solvera Lynx d.d.
Stegne 23A
SI-1000 Ljubljana
Slovenia
Email: [email protected]
Phone: +386 1 40 12 860
Fax: +386 1 40 12 861

5
2.4. ADVANCED FEATURES
• 868 and 915 MHz ISM band LongRange™ for Europe and North America
• Wide coverage range from 1,5 - 2,5 km (urban areas) to 10 km (suburban areas)
• Uses LoRa modulation under LoRaWAN™ v 1.0.1. protocol
• This is not a point to point device and can not be used in this manner
• Long Range and Low Power
• Radio transmission data through LoRaWAN™
• Long Battery Life
• Battery powered device
• Versatile Applications
• Electricity/Heat/Water meters
• IoT applications in Home/Building/Facility Energy Meters
• Data types - optional: counter (unconrmed data type) / counter & logger (conrmed data type)
• OTA-C: specication will be sent on request
• 100 most recent measurments are saved localy in case of network failure
1. PULSE COUNTER (ComBox.L CI-B)
• 15 min or 1 hour measuring/sending period
• 1x Ultra Low Power Counter – Left connector
• 1x Low Power Counter – Right connector
• 2x Tampering detection (1x per counter)
2. STATE SENSOR (ComBox.L DI-B)
• 4x Digital input
• Sending data once per hour or according to change of state on input
(within LoRaWAN protocol limitations)
• 1x device ComBox.L
• 2x battery LI-SOCI2 LS14500 3,6 V
• 1x cable for counter or temperature probe (optionally 2x, depending on the type of the device)
• 4x screw with O-ring
• 1x plastic plug (optional, depending on the type of device)

6
3. TEHNICAL DATA
3.1. DIMENSIONS
Values in millimetre
1. RADIO
• Frequency: 868 MHz
• TX Power: 14 dBm (25 mW)
• RX Sensitivity: -139 dBm
• Modulation: LoRa
• MAC Layer: LoRaWAN
2.
• IImpedance: 22 kΩ
• Capacitance: 110 pF
• Voltage: 3.6 V
• Impedance: ≥ 4 kΩ
• Capacitance: 325 pF
• Voltage: 3.6 V
• Battery: 2x AA (LI-SOCI2 LS145000 3,6V)
• Battery Capacity: 2 x 2600 mAh
• Operation: -20 °C to +60 °C
• Storage: -20 °C to +70 °C
• Dimensions: 200 x 90 x 43 mm
• Weight: 280 g
• IP Protection: IP67 (IEC 60529)
3. TEMPERATURE SENSOR (ComBox.L 2T-B)
• 2x Temperature input (Pt 1000)
• 15 min measuring/sending period

7
• PULSE COUNTER (ComBox.L CI-B)
• STATE SENSOR (ComBox.L DI-B)
• TEMPERATURE SENSOR (ComBox.L 2T-B)
Left connector Right connector
CI-B (CNT1=10Hz,CNT2=0Hz)
Period Autonomy @ SF7 Autonomy @ SF12
4 packets/hour 5 0,7
1 packet/hour 6,7 2,3
1 packet /day 7,5 6,9
CI-B (CNT1=10Hz,CNT2=1Hz)
Period Autonomy @ SF7 Autonomy @ SF12
4 packets/hour 1,5 0,5
1 packet/hour 1,7 1,1
1 packet /day 1,7 1,7
CI-B (CNT1=70Hz,CNT2=0Hz)
Period Autonomy @ SF7 Autonomy @ SF12
4 packets/hour 4,2 0,7
1 packet/hour 5,3 2,1
1 packet /day 5,8 5,4
• Autonomy
• 15 min measuring/sending period
• Frequency CNT 1: average of 70 Hz throughout sending period
• Frequency CNT2: 1 Hz MAX
• Min. pulse lenght: 5 ms

8
• 15 min measuring/sending period
• 2 x Temperature input (Pt1000)
Left connector Right connector
2T-B
Period Autonomy @ SF7 Autonomy @ SF12
4 packets/hour 6,1 0,8
1 packet/hour 8,5 2,6
1 packet /day 9,7 8,7
• Autonomy
Left connector Right connector
DI-B
Period Autonomy @ SF7 Autonomy @ SF12
4 packets/hour 6,1 0,9
1 packet/hour 8,5 2,7
1 packet /day 9,7 8,8
• Change of state or 1 h sending period (regarding LoRaWAN protocol limitations)
• 4 x Digital Input
• Autonomy

9
• Do not mount device beside any other electrical device or antenna
• The ComBox.L device must be vertically mounted, the antenna must be on top
• Before device placement you must observe nearby metal objects and possible RF
interference devices
• The device should be mounted and positioned in a shortest way to the base station
• Do not place the device in a shaft which is too deep under ground
• There are two buttons on the PCB. The
upper left one is MODE (1) and the lower
right one is RST (2) (Reset).The reset
button is used for rebooting the device
and resetting the counters. After the reset
is asserted, the device starts registration
to the network.
5. INSTALLATION
5.1. NOTIFICATION FOR INSTALLATION
5.2. HARDWARE INSTALLATION
• PCB contains two battery holders for two AA size batteries. The device is powered by two SAFT
LS14500 3,6V batteries. Observe the battery polarity when inserting the batteries.The positive
pole is on the left side and the negative pole is on the right side, at the spring (Picture 3, 4 and 5).
Picture 1. Device specications
Picture 2. PCB
• On the front side of the ComBox.L
device (Picture 1), you can see the device
manufacturer and its DevEUI address. On
the backside of the device (Picture 1) you
can see device specications.

10
• Take the supplied cable and attached it to the input of the device. Secure the safety screw
(Picture 6 and 7) to prevent cable disconnection and insure the IP rating of connector.
• Interference with the device interior is permitted only when replacing batteries. Any other
interference with the device is strictly prohibited.
• Batteries are standard AA size batteries, but if you insert 1.5 V alkaline batteries, the device
will not work. Use ONLY SAFT LS14500 batteries.
Pictures 3, 4 and 5. Holders for two AA size batteries
Pictures 6 and 7: Cable Connection
+ - + -
Indice
Altri manuali Solvera Lynx Registratore di dati