STEP 9INSTALLING THE ROVNAV 6 AND REMOTE TRANSDUCER ONTO AN ROVMake sure the ROVNav 6 is acoustically and electrically isolated from the ROV body.The Remote Transducer Cable (312-8044) is limited to 4 metres in length. Position the Remote Transducer so it is no more than 4 metres and has a clear line-of-sight view of the target transponder.Make sure the battery is connected prior to using the ROVNav 6 for acoustic commands, this reduces the power requirements from the ROV MUX.INSTALLING THE EQUIPMENTDo not attach the Remote Transducer to an extendable ram on an ROV if the extended ram and location of the ROVNav 6 is over 4 metres.When securing the Remote Transducer to an extendable ram, make sure the cable does not become trapped when the ram is retracted.Do not allow cables to vibrate on the outside of the hull where flow may make the cable strum and fatigue.The TCVR Comms & Power 8-Way Cable (312-8017), and Remote Transducer Cable (312-8044) are flexible, but the bend radius should not be too tight. Do not kink the cables. WARNINGS
1