Spa Sciences LEXI Manuale utente

User Guide
Model: LX-1917
Intense Pulse Light (IPL)
Permanent Hair Removal
System


CONTENTS
1 Recommendation of Use
1.1 Warnings
1.2 Contraindications
1.3 Adverse Reactions
1.4 Precautions
2 Intented Use & indications for Use
3 Product Description
3.1 Specications
3.2 Accessories List
3.3 Main Device
4 Using Instructions
4.1 Check for these situations before use
4.2 Skin sensitivity test
4.3 Energy Selection
4.4 Usage instructions for operation
5 Maintenance
5.1 Cleaning
5.2 Environment protection
6 Warranty
6.1 Warranty period
6.2 Outside warranty period
7 Safety
8 Symbols description
9 Manufacturer Information
2
2
3
3
4
4
4
5
6
7
9
9
9
9
10
12
12
12
12
12
12
14
21
22

2 | LEXI
1. Recommendation of Use
Please read the complete instruction manual before you use the LEXI
Permanent Hair Removal (Model: LX-1917). It will give you a better
understanding of how the product works, and you’ll be able to enjoy
the best results.
1.1 Warnings
1. This device is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, unless they have
been given supervision or instruction concerning use of the device by
a person responsible for their safety.
2. Children should be supervised to ensure that they do not play with
the device.
3. Always check the device before you use it. Do not use the device or
adapter if it is damaged.Always replace a damaged part with one of
the original type.
4. Do not use the device if the UV lter of the light exit window and/ or
attachment is broken.
5. Do not modify or cut off any part of the adapter or the cord, as this
causes a hazardous situation.
6. Do not use any pencil or pen to mark the areas to be treated. This
may cause burns on your skin.
7. Adapter, light exit window and the lter of the attachments can
become very hot after usage. Do not touch the adapter, inner
part of the light exit window and the lter or the inner part of the
attachments without having these cool down.
8. If you experience discomfort or have a concern about its use, stop use
immediately and contact your doctor.
9. Do not use the equipment if you notice a change in operating system
performance, the system is damaged, or any of its components are
worn or frayed.
10. Do not use it on the head, ears, nipples, genitals or anus.
11. Never subject the appliance to heavy shocks and do not shake or
drop it.
12. Do not put metal objects into the heat dissipation holes, there is a
danger of electric shock.
13. Store the device in a ventilated and dry environment.
14. Do not put the device in water or place it in a humid environment.

LEXI |3
1.2 Contraindications
1. Do not use the device if you are under the age of 18.
2. Do not use the device if you have the Fitzpatrick Skin in Type V and
Type VI.
3. Do not use the device if you are red/gray/white hair.
4. Do not use this device if you are photosensitive.
5. Do not use this product for women during pregnancy, preparation or
lactation.
6. Do not use the device if you have heart disease, hypertension,
malignant tumor, infectious skin disease, burn skin disease and
hypercoagulability disorders.
7. Do not use the device if you have skin problems such as psoriasis,
eczema, herpes, wound or rash etc.
8. Skin sunburned or burnt are not allowed to use until fully recovered.
9. Do not use If the skin treatment area has tattoos, dark brown or black
spots (such as dark freckles, birthmarks, moles or warts).
10. Do not use the device if you have any active implants such as a
pacemaker, neurostimulator, insulin pump etc.
11. Do not use the device if you take any of the medications below:
• You are taking photosensitizing agents or medications.
• Your skin is currently being treated with or has recently been
treated in the past week
• You have taken any form of isotretinoin Accutane or
Roaccutane in the last six months
• You have taken anticoagulation medications, including heavy
use of aspirin in the last a week.
1.3 Adverse Reactions
1. This product has no side effects, but if you are sensitive to light,
please stop using immediately.
2. If you experience any discomfort, skin discoloration, skin damage, or
any other concerns develop, stop using immediately and consult your
physician.

4 | LEXI
1.4 Precautions
1. Do not look directly at the light source and wear protective glasses.
2. Do not block the heat dissipation holes, so as not to affect the use
and the life of the device.
3. Before operation, you need to clean the operation part, and do not
apply any cosmetics and skin care products, so as not to affect the
effect of the device.
4. Do not use perfume, facial mask and cosmetics containing frosted
beads after hair removal.
5. Please avoid UV exposure within 24 hours after depilation. If
necessary, please apply sun cream.
6. If you need plastic surgery after depilation (only the depilated area),
please consult your doctor in detail.
7. It is recommended to use pure plant moisturizing and repairing
products.
8. If the casing of the equipment is damaged or the instrument
accidentally enters the water, please send it back to the manufacturer
for repair, and do not repair the equipment without authorization.
9. Do not disassemble the device by yourself.
10. When the device fails to operate normally, please send the
equipment and related accessories back to the manufacturer, and the
professional maintenance personnel of our company will overhaul
them.
11. If you experience discomfort, reduce the light intensity setting and
consult your doctor.
2 Intended Use & Indications for Use
The LEXI IPL Permanent Hair Removal System is an over the-counter device
intended for removal of unwanted body and/or facial hair.
3 Product Description
The LEXI IPL Permanent Hair Removal System is a personal, light-based,
hair reduction device intended to be sold overthe-counter. The device
provides hair reduction using IPL technology. The device provides hair
reduction using Intense Pulsed Light (IPL) technology.

LEXI |5
It works below the skin’s surface and does not involve any cutting or pulling,
reducing hair growth with minimal pain.
The device is only powered by the external power adapter and its IPL
emission activation is by nger switch. The device mainly contains a Xenon
lamp and a skin sensor to detect appropriate skin contact. If the device is
not properly applied to the treatment area (in full contact with the skin), the
device cannot emit the treatment light pulses. The device is for single-
person use only.
3.1 Specication
Product name LEXI IPL Permanent Hair
Removal System
Model LX-1917
Power source
Adapter:
Input: 100-240V~50/60Hz, 0.8A
Output: 12.0Vdc, 3.0A
Dimensions 148.85mm x 64.7mm x 32mm
Weight 200g
Wavelength 510-1100nm
Energy medium Xenon Arc Flashlamp

6 | LEXI
Pulse duration 9-12 milliseconds
Energy density 2.2-4.0J/cm²
Spot size (size of treatment
window) 3.0cm2
Delivery device Direct illumination to tissue
Pulsing control Finger switch
Location for use OTC
Safety and EMC
IEC 60601-1
IEC 60601-1-2
IEC 60601-1-11
IEC 60601-2-57
IEC 62471
IEC 60601-1-6
Biocompatibility ISO 10993-5
ISO 10993-10
Operating Environment Temperature: 0~40°C
Humidity: <60%RH
Storage Environment Temperature: -20~60°C
Humidity: <60%RH
Name Quantity
LEXI IPL Permanent Hair
Removal System 1 pc
User Manual 1 pc
Adapter 1 pc
Sunglasses 1 pc
Manual shaver 1 pc
Replacement lampshade 1 pc
3.2 Accessories List
Components and Accessories List for all package is as below.

LEXI |7
3.3 Main Device
3.3.1 Buttons
Explanation:
• Power button:
1) Short press to turn on the device.
2) Press and hold the power button for more than 3 seconds to turn off
the device.
3) When the device is opening, short press the power button can select
the gears.
Figure 3-1. Main Device of model LX-1917
Power
Buttom
LCD
Display
Mode/Flash
Button
Light-emitting
Treatment Window
Power Connector
Detachable
Lamshade

8 | LEXI
• Mode/Flash button:
1) The default startup is manual ash mode, long press the ash button
to switch to automatic ash mode, at this time, the LED display will
show a “ “ icon.
2) When the device selects the automatic ash mode, the screen
display icon “ “, press the ash button, then the device will start
ashing automatically
3) When the device selects the manual ash mode, the device can only
ash once every time the ash button is pressed.
3.3.2 LCD display
Remaining Flashing Count
Gear
(Flash Intensity)
Cooling Fan
Auto Flash
Mode
Temperature
Warning
Explanation:
• Power button:
1. The value of the remaining ash count will decrease accordingly
with the number of uses. The initial value is 999999, and the screen
displays the “ “ icon.
2. The working mode have 5 level, a sector represents a level, and when
the corresponding level is selected, the corresponding number of
sectors will be displayed.
3. When the automatic ash mode is selected, there will be displayed “
” on the display, otherwise it is the manual ash mode.
4. When the cooling fan is turned on, there will be displayed “ ” on the
display.
5. When the product temperature is greater than 55°C, the temperature
alarm icon “ ” ashes.
Questo manuale è adatto per i seguenti modelli
1
Indice