SpectraPure RO Systems Manuale utente

Drinking Water Kit with Non-Air Gap Faucet
for RO and RO/DI Systems
(Including “-MF” Systems)
INSTRUCTIONS
WARNING
Please read carefully before proceeding with installation. Failure to follow any
attached instructions or operating parameter may lead to the product’s failure and
possible damage to property.
SpectraPure®Inc.assumes no responsibility for water damage due to leaks.
It is the user’s responsibility to determine that the system is leak-free.
v4 2013-12-03

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
2
Thank You for your purchase of a
SpectraPure
®
System. With proper installation and maintenance, this system
will provide you with high quality water for years to come. All SpectraPure
®
products are rigorously tested
by us for safety and reliability. If you have any questions or concerns, please contact our customer service
department at 1.800.685.2783 or refer to our online troubleshooting at www.spectrapure.com.
TABLE OF CONTENTS
Operating Instructions
Feed water Requirements .................................................................................................................................. 3
Contents of DWK ................................................................................................................................................... 3
Configuring a Manual Flush (-MF) System For the Drinking Water Kit ............................................... 4
Configuring a Legacy (non -MF/-AF) System For the Drinking Water Kit ........................................... 5
Ice Maker Hookup (optional) ............................................................................................................................. 5
Diagram of RO/DI System With Drinking Water Kit Installed ................................................................. 6
Preparation .............................................................................................................................................................. 7
Feed Supply Valve Installation .......................................................................................................................... 8
Faucet Installation ................................................................................................................................................. 9
Drain Saddle Installation .................................................................................................................................. 10
Installing Pressurized Storage Tank and Mounting System .................................................................. 11
Startup Procedures ............................................................................................................................................. 11
Maintenance
Sanitizing the RO/DI System with DWK ...................................................................................................... 12
Recharging the Bladder Tank ......................................................................................................................... 12
Troubleshooting Guide
Troubleshooting for the Drinking Water Kits ...................................................................................... 13 -14
Warranty Information ..................................................................................................................................................... 15
Replacement & Optional Parts ..................................................................................................................................... 16
Copyright © 2013 by SpectraPure Inc.
ALL RIGHTS RESERVED
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means,
electronic, mechanical, photocopying, recording or otherwise without the prior written permission of SpectraPure Inc.

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
SpectraPure
®
3
OPERATIONAL SPECIFICATIONS
RO Feed water requirements:
Operating Pressure: 40-80 psi (2.75-6.9 bar)
pH Range: 3-11
Maximum Temperature: 100°F (38°C)
Maximum Feed Turbidity: 1.0 NTU
Maximum Silt Density Index: 5.0 (based on 15 min. test time)
Maximum Chlorine: < 0.1 ppm
Maximum TDS: 1500 ppm
Maximum Hardness: 10 grains (170 ppm as CaCO3)
Maximum Iron: < 0.1 ppm
Maximum Manganese: < 0.1 ppm
Maximum Hydrogen Sulfide: 0 ppm
Langelier Saturation Index (LSI): must be negative
NOTE: MOST MUNICIPAL WATER SUPPLIES MEET THE ABOVE REQUIREMENTS. IF WELL WATER IS USED,
PLEASE MAKE SURE THAT YOU OBTAIN A WATER TEST BEFORE INSTALLATION.
NOTE: THE OPERATING PRESSURE IN YOUR HOME SHOULD BE TESTED OVER A 24 HOUR PERIOD TO OBTAIN
THE MAXIMUM PRESSURE. IF IT IS ABOVE 80 psi THEN A PRESSURE REGULATOR MAY BE REQUIRED.
CONTENTS OF DRINKING WATER KIT
DRINKING WATER ADD-ON KIT
(1) Pressurized Storage Tank (1) Inline Carbon Block w/ Push Fittings
(1) Faucet (with parts bag) (1) Feed Water Adapter
- (1) Galvanized Flange (1) Drain Saddle
- (1) Rubber Washer (1) Ball Valve, Right Angle (for the top of tank)
- (1) Flat Metal Washer with “U” Cutout (1) Automatic Shut-off Valve (ASO)
- (1) Plastic Spacer with Cutout (1) Ball Valve, (2) Check Valves
- (1) Flat Metal Washer (1) Tee (used to redirect RO water before the DI)
(1) Tee for Right-Angle Ball Valve
- (1) 3/8” Quick Connect Plastic Tubing Adapter
IF ANY OF THE ITEMS LISTED ABOVE ARE MISSING PLEASE CONTACT SPECTRAPURE PRIOR TO INSTALLATION.
ALL RETURNS WITHOUT RMA# WILL BE REFUSED. CLAIMS MUST BE WITHIN 10 DAYS FROM RECEIPT.
PRESSURIZED
STORAGE TANK
INLINE CARBON
BLOCK FILTER
FAUCET
RIGHT-ANGLE BALL VALVE
(FOR TANK)
2-WAY BALL VALVE
REDUCTION TEE
2 - 1 lb. CHECK VALVES
ASO VALVE
FAUCET
ADAPTER
FAUCET
PARTS BAG
DRAIN SADDLE
(FOR WASTE TO DRAIN)
1/4" TEE
(USED TO TEE OFF DI
WATER FOR RO/DI
SYSTEMS)
FEED WATER ADAPTER
(FOR TAP LINE)

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
4
CONFIGURING A MANUAL FLUSH SYSTEM FOR THE DRINKING WATER KIT:
SpectraPure “-MF” Systems (MC-RODI-xx-MF, CSPDI-xx-MF, CSP-xx-MF) are configured in such a way as to be incompatible
with the Drinking Water Kit. Follow these steps to convert your “-MF” system into a compatible configuration.
THIS DOES NOT WORK WITH “-AF” SYSTEMS.
1. Disconnect the blue tube, the short yellow tube and the red (or green - whichever you chose during Setup) tube
from the ASO Valve. You should find the short Flow Restrictor inside the red (or green) tube.
2. Disconnect the black tube from the RO membrane housing. Reroute it from the center hole in the back of the bracket
to the left-hand hole (as viewed from behind). Measure 3 inches of black tube above the bracket and cut the black
tube in two. That black tube from the carbon block connects to the only IN port of the ASO.
3. The OUT port of the ASO now connects to the membrane housing input, using a newly-cut length of black tubing
supplied in the kit.
4. Cut the blue tube still connected to the membrane housing down so there is only 1 inch of tubing exposed. Connect
a 1/4" Check Valve to this blue tube with the arrow pointing away from the blue tube.
5. Cut a piece of blue tube down to 2 inches. Connect one end to the the remaining free end of the Check Valve and
the other end to the ASO Valve. (Note: the arrow should be pointed towards the ASO valve.)
6. Disconnect the short yellow tubing from the Y fitting that was once connected to the ASO valve.
7. Insert the red (or green) tube with the Flow Restrictor in that end into that Y fitting.
8. Cut the longer yellow tube that is still attached to the ball valve so that it, the ball valve, and the short yellow tube
matches the length of the red (or green) tube.
9. Reconnect the yellow and red (or green) tubes to the Y fitting. Now you are ready to hook up your drinking water
kit as it is shown in the following pages.
CORRECT CONFIGURATION OF MANUAL FLUSH AND
ASO AFTER CONVERSION FOR DRINKING WATER KIT
CORRECT CONFIGURATION OF MANUAL FLUSH
AFTER CONVERSION FOR DRINKING WATER KIT
IN port of ASO Valve
Check Valve OUT port of ASO Valve
Membrane Housing
ASO Valve
Waste
Water Port
Stem Adaptor
Connect Yellow
Tubing to Drain
Flow Restrictor Inside

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
SpectraPure
®
5
ICE MAKER HOOKUP (OPTIONAL)
1. Turn off feed supply valve and the ball valve on tank.
2. Locate the Blue tube that leads to the faucet.
3. Cut the tube and reconnect the cut ends with a 3/8” x 3/8” x 1/4” Tee.
4. Connect 1/4” Tubing to the third leg of the tee and route to refrigerator.
5. Turn on feed supply valve and the ball valve on tank.
CONFIGURING A LEGACY SYSTEM FOR THE DRINKING WATER KIT:
(Including MPRO, MPDI, CSP, CSPDI and MAXCAP models without automatic or manual flush)
1. Locate the Black Tube between the Carbon Filter and the Membrane.
2. Cut the Black Tube in two.
3. Insert the cut end from the Carbon Filter into the IN Port of the ASO Valve.
4. Insert the cut end from the RO Membrane Housing into the OUT Port of the ASO Valve.
5. Locate the Blue Tube (product water) that leaves the RO Membrane Housing.
6. Cut the Blue Tube 2” from the membrane housing.
7. Using the 1 lb Check Valve, reconnect the two cut ends with the arrow pointing away from the membrane.
8. Position the Blue Tube along side the ASO Valve to determine where the blue tube needs to be cut. Then cut the
blue tube and reconnect the two cut ends with the two remaining ports of the ASO Valve. (See Diagram on Page 6.)

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
6
RO/DI SYSTEM WITH DRINKING WATER KIT INSTALLED
FOR RO-ONLY SYSTEMS:
CONNECT ASO PORT “A” TO TANK TEE “B” .
(CHECK VALVE AND TEE NOT REQUIRED)
“A”
“B”

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
SpectraPure
®
7
PREPARATION
1. Prepare for installation by removing all items from under the sink. Locate and turn off the COLD water supply and
open the sink faucet to relieve any remaining pressure.
2. Determine an appropriate location for the Drinking Water System, Bladder Tank, Feed Water Connection, Drain
Saddle, and the Non -Air Gap Faucet for your specific application.
3. TOOLS RECOMMENDED FOR INSTALLATION:
- Adjustable Wrench
- Sharp Knife
- Open End Wrench
- Phillips Screw Driver
- Needle Nose Pliers- Adjustable Pliers
- Electric Drill
- 1/2" Hole Saw Bit for Faucet Opening (depends on faucet used)
- Round Knock out Punch for Stainless Sinks, 1/2"
DRILL HOLE FOR FAUCET IN A PORCELAIN SINK
NOTE: Porcelain sink material is extremely hard and can crack or chip quite easily. To avoid this, use extreme caution
when drilling. A carbide tipped masonry bit is recommended. SpectraPure®accepts no responsibility for
consequential damage resulting from the installation of the faucet.
STEP 1. Determine a desired location for the faucet on your sink and place a piece of masking tape on the location
where the hole is to be drilled. Mark the center of the hole on the tape.
STEP 2. Use a variable speed drill on the slowest speed. Drill a 1/8" Pilot hole through both porcelain and metal casing
of sink at the center of the desired location. (If drill bit gets hot it may cause the porcelain to crack or chip.)
STEP 3. Use a 1/2” hole saw and proceed to drill the large hole. Keep drill speed on the slowest speed and use lubricating
oil or liquid soap to keep the hole saw cool during cutting.
STEP 4. Make sure the surroundings of the sink are cooled before mounting the faucet to the sink after drilling. Remove
all sharp edges with a file.
PUNCH HOLE FOR FAUCET IN STAINLESS STEEL SINK
STEP 1. If mounting faucet to a Stainless Steel Sink you will need a bimetal or carbide tipped hole saw.
STEP 2. The Faucet opening should be centered between the back splash and the edge of the sink, ideally on the
same side as the vertical drain pipe.
STEP 3. Drill a 1/4” pilot hole. Use a bimetal or carbide tipped hole saw to punch the 1/2” hole in the sink.

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
8
FEED SUPPLY VALVE INSTALLATION
STEP 1. Follow the cold water line from shut-off valve to the existing faucet and unscrew the threaded connection.
STEP 2. Insert feed supply valve between cold water line and existing connection.
STEP 3. Follow the assembly sequence shown for attaching valve to the existing cold water line.
STEP 4. Connect Black line from RO system as shown in Fig 1.
a. Remove the 1/2" Compression Nut from Valve body. Be carefull not to loose the plastic or brass Insert and
the Conical Compression Sleeve.
b. Insert the 1/4” Black Tubing into the Compression Nut with the threads towards the end of the tube.
c. Slip the Conical Compression Sleeve onto the Black Tube with the long slope pointing toward the end of
the tube.
d. Place the Insert into the end of the Black Tubing. Make sure you push the insert in all the way.
e. Tighten Compression Nut back on the Valve body.
STEP 5. When installation of the valve is complete, check for leaks as follows:
a. Close Feed Supply Valve that you just installed.
b. Open cold water supply valve and check for leaks around feed supply valve fittings. Tighten if necessary.
NOTE: To be certain of the cold line; turn on the hot water, allow water to run until pipe becomes warm. Then
attach fitting to the cold water line. If you run hot water through your system it will damage the membrane.
FIGURE 1: FEED SUPPLY INSTALLATION
FEED VALVE
INSTALL ON COLD WATER LINE

SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
SpectraPure
®
9
FAUCET INSTALLATION
1. Place the chrome counter plate and large rubber washer over the threaded shaft on the faucet and insert this
assembly into hole previously drilled on page 7.
2. Place the small rubber washer, locating washer, flat metal washer, and hex nut in sequence over the threaded shaft
and temporarily hand-tighten. (Fig. 2)
3. Insert the Blue Tube into the Compression Nut with the threads towards the end of the tube. Then add the
Compression Sleeve.
4. Place the Insert into the end of the Blue Tubing. Make sure you push the insert in all the way. Screw the Compression
Nut onto the threaded shaft.
5. Securely tighten both hex nut and Compression Nut.
6. DO NOT CUT EXCESS TUBING AT THIS POINT. YOU WILL NEED THE TUBING TO INSTALL THE TANK.
TIP: When connecting the tubes to the hose barbs, try using HOT water to soften the plastic tubes. When connecting the
drain lines to the saddle, make the lengths as short and straight as possible to reduce drainage noise.
Figure 2 Figure 3: INSTALLATION FOR TYPICAL 3-STAGE RO SYSTEM
NON AIR- GAP FAUCET PARTS LIST
– Faucet
– Chrome Counter Plate
– Locating Washer
– Large Rubber Washer
– Small Rubber Washer
– Flat Metal Washer
– Hex Nut
– Plastic Conical Compression Sleeve
– Insert
– Compression Nut

SpectraPure
®
SpectraPure
®
Inc.
480.894.5437 Call us toll-free 1.800.685.2783
2167 East Fifth St, Tempe, Arizona 85281
10
DRAIN SADDLE INSTALLATION
1. Refer to Figure 4 and determine the location for the drain saddle assembly and drain hole. It must be located above
the “P” trap (“U” shaped bend in drain pipe) on the sink side of the drain pipe.
2. Place the half of the drain saddle with threaded nipple at a predetermined location. Slide a pencil through the plastic
nipple and make a mark on the drain pipe.
3. Use a small punch and indent a start position to prevent the drill bit from wandering. Drill a 3/8" hole in the drain
pipe through the mark on one side only, do not drill through both sides of the drain pipe.
4. Clean any loose shavings from around the hole.
5. Refer to Figure 5 showing the drain saddle assembly sequence. Press nuts in back half of drain saddle assembly.
6. Align the front half of the drain saddle by inserting a pencil through the plastic nipple and the newly drilled hole in
the drain pipe.
7. Install the back half of the drain saddle and clamp assembly to drain pipe by screwing in the mounting bolts until snug.
Figure 4: Drain Saddle Mounting Locations
Figure 5: Drain Saddle Assembly Sequence
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali SpectraPure Sistema idrico
Manuali Sistema idrico popolari di altre marche

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuale utente

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuale utente

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuale utente

Microline
Microline T.F.C.-4 Manuale

Eureka Forbes
Eureka Forbes Aquaguard Select Manuale utente

Cetetherm
Cetetherm AquaEfficiency Manuale utente