SPI Infrared Phantom 2 M2-D Guida rapida

Phantom 2 M2-D
C
onf
i
gur
ati
on
Ver
1.0
This document is the property of Sierra Pacific Innovations Corp (“SPI
Corp”). SPI Corp reserves all rights to this document, data, invention, and
content herein described. This documentis confidential, including the fact
of its existence and is not to be disclosed, in whole or in part, to any other
party and it shall not be duplicated, used, transmitted or copied in any form
without the express prior written permission of SPI Corp. Acceptance of
this document will be construed as acceptance of the foregoing conditions.

www.x20.org
- Page 2 of 35 –
- SPI Corp Proprietary and Confidential Information -
Compilation and Publication Notice
This manual is covering the latest product descriptions and
specifications.
The contents of this manual and the specifications of this product are
subject to change without notice.
SPI Corp reserves the right to make changes without notice in the
specifications and materials contained herein and shall not be
responsible for any damages (including consequential) caused by
reliance on the materials presented, including but not limited to
typographical and other errors relating to the publication.
For Further information please contact
Sierra Pacific Innovations Corp

www.x20.org
- Page 3 of 35 –
- SPI Corp Proprietary and Confidential Information -
Table of Content
1 Safety notes.................................................................................... 6
2 Introduction .................................................................................. 5
3 Futaba t14sg Configuration......................................................... 7
4 LightBridge Configuration & Calibratrion............................. 14
5 M2-D SBUS Adapter Configuration & Calibration ...... 17
6 System Test.................................................................................. 30
6.1
T
e
s
t
i
n
g
R
e
t
urn
to Home
F
un
c
t
i
on
..................................................................
30
6.2
C
o
mm
un
i
c
a
t
i
on
Disconnect
T
e
s
t
i
n
g
...............................................................
30
6.3
C
a
m
e
r
a
Pitch
T
e
s
t
i
n
g
....................................................................................
31
6.4
D
a
y
/
I
R
/
NU
C
/
P
o
l
a
r
i
t
y
....................................................................................
31
6.5 Zoom In/Out ...............................................................................................
32
6.6 Bypass/Single Yaw .....................................................................................
33
6.7 Motor
on
/
o
ff
...............................................................................................
34
7 Operation..................................................................................... 3

www.x20.org
- Page 6 of 35–
- SPI Corp Proprietary and Confidential Information -
1 Introduction
The document describes the configuration and calibration of Phantom
2 M2-D.
The following table describes which component should be
configured and/or calibrated:
Component
Configuration
Calibration
Section
Futaba t14sg
√
-
3
DJI Lightbridge
√
√
4
M2-D SBUS Adapter
√
√
5
DJI Phantom
-
√
6

www.x20.org
- Page 7 of 35–
- SPI Corp Proprietary and Confidential Information -
2 Safety notes
Remove propellers before any configuration / calibration activity.
During configuration and/or calibration activity propellers should be
removed. The propellers can be re-assembled at the end of the
configuration / calibration activity.
The cover of the Phantom 2 should be removed to allow access to the
SBUS adapter USB port.

www.x20.org
- Page 8 of 35–
- SPI Corp Proprietary and Confidential Information -
3 Futaba t14sg Configuration
The Futaba t14sg is factory configured to 8 channels by default. The
first step would be to enable 12 channels support.
3.1 Setting 12 Channels Support Mode
The following image defines the control 12 channels in Futaba
t14sg.
a. Double click on “System” key
b. Go to “TRAINER” and press “RTN” key
c. Go to last screen and chose the 12 channels option

www.x20.org
- Page 9 of 35–
- SPI Corp Proprietary and Confidential Information -
The next step wouldbe to configure 12 function keys
3.2 Configuring the Function Keys
The following images define the name convention for the control
sticks and switches of the Futaba t14sg
M2-D Name Convention
DJI Name Convention
IOC switch
X2
FW/BWD stick
E

www.x20.org
- Page 10 of 35–
- SPI Corp Proprietary and Confidential Information -
LFT/RGT stick A
M2-D Name Convention
DJI Name Convention
Safety
U
Altitude stick
T
YAW stick
R

www.x20.org
- Page 10 of 35 –
- SPI Corp Proprietary and Confidential Information -

www.x20.org
- Page 11 of 35 –
- SPI Corp Proprietary and Confidential Information -
The following images describes the name convention for sticks and
switches movement
Following the following steps to define the function keys:
Indice

















