- Read all instructions before using this heater take care to ensure you fully understand
the instructions concerning electricity and fuel supply.
- Know how to start and stop the unit. Be quite familiar with the controls.
- Allow a minimum room size as listed in the technical specifications.
- Not for domestic use, space heating only.
- Local regulations should be followed as to the installation of industrial heaters.
- Do not operate the heater if it is damaged.
- Never leave the heater unattended whilst running.
- Permanent ventilation to the outside atmosphere must be provided. Allow 96 sq.cm for
every 1000W input divided equally between floor and high levels.
- Do not operate this heater in basements or below ground.
- Do not restrict under any circumstances either the inlet or outlet end of the heater.
- The heater must not be used in close proximity to combustible or flammable materials.
- The heater must operate in a space with clearance of 1m above and behind and 600mm
on the sides. A guard must be placed 900mm away from the heater outlet to prevent the
approach of combustible materials.
- Always use the handle to move the heater after it has been operating as other parts of
the heater may be very hot.
Use only clean filtered diesel or kerosene as fuel. Do not refill the fuel tank while the
heater is running or is still hot.
- Follow the maintenance procedures and fault-finding techniques outlined in the manual.
- To prevent injury always disconnect the power plug before disassembling any part of the
- Do not carry out temporary repairs on worn or damaged electrical cords and plugs.
- Have worn, cut or damaged cords and plugs replaced by an authorised service person or
- Do not pull on the electrical cord in order to unplug the unit.
- Do not use this heater in the rain or when it is at risk of being sprayed with water.
The JETFIRE range of heaters is designed to run off 230V Single-Phase 50Hz electrical
supply. The unit should be plugged into a 10A outlet.
- The appliances must be earthed.
- If the Plug needs to be replaced to suit local requirements a qualified electrician should
carry out the replacement taking care to earth the unit and maintain the correct phase
connection as per the wiring diagram.
- Please only use the following fuel types in the heater:
Kerosene with viscosity of 1.3 cSt or Diesel with viscosity of 1.5 cSt.