515
"Please read this entire manual before installation and use of this pellet fuel-
burning room heater. Failure to follow these instructions could result in
property damage, bodily injury or even death."
"Contact local building or fire officials about restrictions and installation
inspection requirements in your area.

Ashby-P Insert
2
General Information ...................................................................................................... 4
Installation Check List .............................................................................................. 5, 6
Ashby-P Layout Diagram .............................................................................................. 7
Ashby-P Dimensions, Location & Clearances ........................................................... 8-9
Approved Installations .................................................................................................. 10
Installing as a Zero-Clearance Unit .............................................................................. 11
Surround Instructions.................................................................................................... 12
Exhaust Venting: Approved Materials.......................................................................... 13
Venting – Typical PL Vent Components ...................................................... 14
Venting - Determining Materials .................................................................. 15
Venting - Termination Requirements.........................................................16-17
Venting: Termination Clearance Requirements ............................................ 18
Venting – Installations................................................................................19-21
Outside Combustion Air ............................................................................................. 22
Mobile Home Installation ........................................................................................... 23
Ashby-P Operation........................................................................................................ 24
Preventing Chimney Fires.............................................................................. 24
Ashby-P Approved Fuels............................................................................... 24
Installation Check .......................................................................................... 25
Ashby-P Ashpan Locations........................................................................................... 26
Control Board Features ............................................................................................27-28
Pre-Lighting Instructions .........................................................................................28-29
Lighting Instructions................................................................................................29-30
TABLE OF CONTENTS

Ashby-P Insert
3
Shutting Off the Insert .................................................................................................. 30
Combustion Air Damper – Location and Adjustments................................................. 31
Importance of Proper Draft............................................................................ 31
Initial Damper Settings .................................................................................. 32
Flame Pattern Characteristics ........................................................................ 32
Use of a Thermostat .................................................................................................... 33
Thermostat Control & Pilot Settings............................................................................. 34
Diagnostic Features................................................................................................. 34, 35
Safety Features.............................................................................................................. 35
Ashby-P Maintenance................................................................................................... 36
Versa Grate System................................................................................................. 36, 37
Daily Maintenance (Versa Grate System) ...............................................................37-39
Periodic Maintenance...............................................................................................39-42
Yearly Maintenance ................................................................................................ 42, 43
Safe Operation .............................................................................................................. 43
Wiring Schematic.......................................................................................................... 44
Troubleshooting & Frequently Asked Questions ...............................................45-48
Ashby-P Parts Breakdown ......................................................................................49-51
Warranty ....................................................................................................................... 52
Ashby-P Info & Notes .................................................................................................. 53
EMAIL: support@stcroixstoves.com
WEB ADDRESS: www.stcroixstoves.com

Ashby-P Insert
4
GENERAL INFORMATION SAFETY PRECAUTIONS
SAFETY NOTICE: The Ashby-P must be properly installed in order to prevent the possibility
of a house fire! These installation instructions must be strictly observed! The Maintenance
schedule must be followed as described in this manual. Failure to follow instructions may
result in property damage, bodily injury or even death.
The Ashby-P’s exhaust system works with negative combustion chamber pressure and a slightly
positive chimney pressure. Therefore, it is imperative that the air intake and exhaust system be
airtight and installed correctly. Do not install a flue damper in the exhaust vent of this unit.
Do not connect this unit to a chimney flue serving another appliance.
BUILDING PERMIT
Contact the local building officials to obtain a permit and information on any local installation
restrictions and inspection requirements.
DEFINITION OF “INSERT”
The word “Insert” as used in this manual to describe the Ashby-P is interpreted to mean an Insert
approved for PFI Premium pellets. This insert is not intended as the sole source of heat.
EMISSIONS TESTING
U.S. ENVIRONMENTAL PROTECTION AGENCY Certified to comply with 2020 particulate
emission standards using pellet fuel.
Certified to the 2020 Phase of ASTM E2779-2010. Heat Output: 7628 BTU/hr – 29916 BTU/hr,
Efficiency: 65.5% using the higher Heat Value of the Fuel. Emission Rate .981 gr/h
SAFETY TESTING
The Ashby-P has been independently tested and listed by Warnock Hersey Laboratories in
accordance with the proposed ASTM E 1509-2004 Standards and the applicable portions of UL
1482 and ULC S627/B366.2, and Oregon Administrative Rules 814-23-901 through 814-23-
909, stating requirements for installation the Ashby-P and for mobile home installations. The
safety-listing label is located on the top of the hopper. Please refer to label for pertinent
information.
DISCLAIMER OF WARRANTY
Since Even Temp Company has no control over the installation of the Ashby-P, Even Temp
Company grants no warranty, implied or stated, for the installation of the Ashby-P and assumes
no responsibility for any special, incidental or consequential damages.
MANUFACTURED BY:
Even Temp Inc
Hwy 34, Waco, NE, 68467
Phone: 1-402-728-5255
Save This Installation & Operations Manual

Ashby-P Insert
5
- FOR USE IN THE U.S. AND CANADA
- MOBILE HOME APPROVED
- CHECK WITH LOCAL AUTHORITIES AND OBTAIN NEEDED PERMITS. OBTAIN
FINAL INSPECTION FROM LOCAL BUILDING OFFICIALS.
- WE RECOMMEND INSTALLATION BY A QUALIFIED PROFESSIONAL OR
DEALER.
- ADHERE TO ALL CLEARANCES SPECIFIED BY THE MANUFACTURER OF THE
VENTING SYSTEM USED.
-
ADHERE TO ALL CLEARANCES SPECIFIED IN THE INSTALLATION
INSTRUCTIONS OF THIS STOVE.
- THIS STOVE USES A POSITIVE PRESSURE VENTING SYSTEM. DO NOT
INSTALL A FLUE DAMPER IN THE EXHAUST SYSTEM OF UNIT.
- DO NOT CONNECT THIS STOVE TO A CHIMNEY SYSTEM THAT IS
CONNECTED TO ANOTHER APPLIANCE.
- DO NOT INSTALL THIS UNIT IN A SLEEPING ROOM.
- INSTALL A SMOKE DETECTOR IN PROXIMITY OF THE STOVE.
- INSTALL A CARBON MONOXIDE DETECTOR IN PROXIMITY OF THE STOVE
ATTENTION
- CONDENSATION
:
When planning the installation of your Stove, keep in mind that
condensation is detrimental to exhaust systems. Install the Stove with a minimum of the
vent system exposed to the cold temperatures outside the envelope of the house.
- BATTERY BACKUP: St Croix does not offer battery backups. They are available online
if you decide to use one. Battery backup systems are useful if the Stove is installed using
horizontal venting only. This prevents any smoke from entering your home in the event of a
power failure.
- OPTIONAL EXHAUST FAN RELAY KIT: With optional relay kit 80P54232 installed in
the stove and connected to an inexpensive UPS battery backup (not part of the kit) you will
have maximum protection against smoke leaking out of the stove in the event of a power
failure. This is considered the best installation when venting horizontally. Contact your
dealer for more information.
1. All joints of PL vent and single wall stainless steel pipe should be fastened by at least 3
screws and correctly installed. (Follow vent manufacturer’s instructions). Seal all joints with
high temperature silicone to create an airtight seal.
INSTALLATION CHECK LIST

Ashby-P Insert
6
2. A certain amount of carbon monoxide may be produced within the Stove as a by-product of
combustion. All exhaust vent connections must be sealed with RTV silicone to assure a gas tight
seal. Any leaks into a confined area caused by faulty installation or improper operation of
the Stove could produce dizziness, nausea and in extreme cases, death. The CO
concentration in the flue gas during the testing was found to be too low and under the accuracy
of the test equipment used for the flue gas analysis. Therefore, the CO emissions could not be
calculated.
3. WARNING: The high temperature paint on this Stove may take several hours of burning at a
high fuel setting to cure fully. During this time, an odor that is not harmful may be evident.
When odors are present, the area around the Stove should be well ventilated.
4. Caution: The high temperature paint can be easily scratched prior to burning the Stove.
5. Have your dealer demonstrate all the operational and maintenance steps necessary for proper
use of the Stove. Sign and return the warranty card to the address listed on the back page.
6. Some odors may be given off during the first few hours of burning during initial break-in.
These odors are normal and not harmful. However, ventilating the room until the odors disappear
is recommended.
7. The Stove will become HOT while in operation. Keep clothing and furniture away from all hot
surfaces.
8. To avoid the possibility of smoke and/or sparks entering the room always keep firebox and ash
pan doors closed whenever the Stove is operating. Smoke detectors, installed in the same general
area as the Stove, may be activated if the Stove door is left open and smoke is allowed to enter
the area.
9. Under certain circumstances an outside source of combustion air may be needed and is
required on all mobile home installations. Use only approved parts. When using outside air for
combustion, check that the outside air inlet is connected to draw fresh air from outside the
building. If room air is used to supply combustion air, room air starvation (not enough make-up
air), operation of exhaust fans and icing of air vents can adversely affect proper Stove operation.
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is
against federal regulations to alter this setting or otherwise operate this wood heater in a manner
inconsistent with operating instructions in this manual.
CAUTION: FAILURE TO FOLLOW THE INSTRUCTIONS IN THE INSTALLATIONS
MANUAL MAY RESULT IN A HOUSE FIRE, PROPERTY DAMAGE, BODILY
INJURY, OR EVEN DEATH. PLEASE FOLLOW INSTALLATION AND
MAINTENANCE INSTRUCTIONS.
CAUTION: NEVER ADD FIRE STARTER TO A HOT STOVE.
CAUTION - Hot Surfaces
- Keep Children away.
- Do not touch during Operation.

Ashby-P Insert
7
Ashby-P
Stove Layout
Figure 1
There are two burn systems used in the Ashby Series of inserts. These systems are
interchangeable in the stove body. This Manual covers the Ashby-P, which uses the Versa Grate
System burn system.
The “Versa Grate System”. Is a Fully Automatic System that offers Self-Ignition. This system
is approved for PFI Premium Pellets.

Ashby-P Insert
8
ASHBY-P DIMENSIONS
Figure 2

Ashby-P Insert
9
Clearance to Combustibles
Figure 3
A - Top of Insert to Combustible Mantle ......................................................... 12”
B - Side of Insert to Combustible Wall ............................................................ 10”
C - Top of Unit to Combustible Top Fascia…………..…………..Does not apply
D - Side of Unit to Combustible Top Fascia…………..…………..Does not apply
Figure 4
The Hearth must extend a minimum of 6” (152 mm) in Front of Unit and beyond each side
of the Fuel Loading and Ash Removal Opening(s). If the hearth is too short a non-combustible
Hearth Extension must be installed.

Ashby-P Insert
10
Approved installations
1. In a Masonry Fireplace – The Masonry Fireplace must be built according to the
requirements of the Standards of Chimneys, Fireplaces, Vents and Solid Fuel
Burning appliances, N.F.P.A. 211 and any National, State or Local codes that apply.
2. In a Zero Clearance Fireplace – The Factory built Zero-Clearance Fireplace and its
Chimney must be listed per UL 127 or ULC S610 standards.
3. As a Zero Clearance Fireplace. When building the unit in as a Zero-Clearance
Fireplace, St. Croix factory Built Cabinet, part # 80P54057, must be used. Follow
instructions on page 11.
Figure 5
Minimum Fireplace Opening
Altri manuali per Ashby-P Insert
1
Indice
Altri manuali St. Croix Camino da interno

St. Croix
St. Croix Ashby-MF Insert Manuale utente

St. Croix
St. Croix Ashby Manuale utente

St. Croix
St. Croix Ashby-P Insert Manuale utente

St. Croix
St. Croix Lincoln SCR Istruzioni per l'installazione e il funzionamento

St. Croix
St. Croix PEPIN Manuale utente

St. Croix
St. Croix YORK Manuale utente

St. Croix
St. Croix Element-P Manuale utente