is caried out according to Appendix 1. The beginning of the label (front - for two labels) is
positioned next to the peeling edge. The pressure shaft is 'locked'. Label tape drivers are
positioned and fixed to the edges without squeezing it.
Turn on.
After the machine is switched on, an advertisment logo is visualised on the display and
the software version after that is switched to operating mode.
Determination of parameter value 'Offset stop'.
The sensor which is reading the end of the label is located at distance 100mm before
the peeling edge and its position cannot be changed. This requires the input of the 'Offset-
stop' parameter / for single-label mode / and 'Offset-stop 1' and 'Offset-stop 2' / for two-label
mode /. This parameter determines the proper positioning of the subsequent label to the
peelinge edge. The values depend on the length of the labels and the distance between
them. For convenience, the measurement of the labels, the distance between them and the
calculation of the offset are done before mounting the label roller on the machine.
In the case of single-label gluing, the parameter value is determined according to
Appendix 2.
In the case of two labels gluing, the parameter values are determined according to
Appendix 3. If the front label is less than 100mm and the back (rear) label is larger than
100mm, it must be started by spreading and gluing the longer label or by spreading and
gluing the back (rear) one.
Working with the menu and changing parameters.
Menu access is password protected, which is fixed and cannot be changed. Through
the menu can select the language, operating mode / one or two labels /.
For the one label mode shall be set : 'Offset stop' and additional adhesive movemnt
time.
For the two labels mode shall be set: the gap between labels on the the tape, the
distance between the labels affixed to the vessel, 'Offset-stop 1', 'Offset-stop 2' and the
movement time for the adhesive. Access and operation with the menu is carried out
according to Appendix 4.
Labeling.
First starting shall be done without a vessel for control. The new label / front - for two
labels mode/, should be just to the peeling edge. Offset-stop adjustments are made if
necessary.
The adhesive procedure is started by pressing the built-in 'Start' button, or by an
external start / 'Start' pedal connected to the intended coupling /. Performance is indicated on
the display. At the completion of the spreading and affixing (gluing) procedure, the label
counter increases. During the working regime any time the key is pressed for more than 3
seconds, the counter is reset.
Adjusting the display.
The brightness and the contrast of the display can be adjusted if needed. Menu
access and operation are described in Appendix 5.