7 Undo Allen screw and M5 nut holding
lower crosspiece.
7
9S30-in M. En
03-05
8 9
9 Remove seal.
Refitting is in reverse sequence.
8 Position drum on solid door, remove
door by lifting it off its hinges.
Rotate drum to the left to bring the
15mm hole level with vertical body
seal. Hexagonal-head screw holding
lower horizontal seal retainer will
show through hole. Unscrew 2 or 3
turns, then perform same procedure
on RH side.
12
1 Using an 8mm socket undo
2 screws. Fit new striker plate.
2 Using socket spanner undo 2 screws
holding latch.
The door locks with 2 separate components :
A latch fixed to the drum and a striker plate fixed on the door.
Adjusting or replacing door locking mechanism