SUNSTONE 1SSB Manuale utente

Read all instructions before you operate your Side
Burner, Save these instructions!
Conforms to ANSI STD Z21.58-2018
Certified to CSA STD 1.6-2018
Outdoor Cooking Gas Appliance
To installer or person assembling burner: Leave this manual with burner for future
reference.
To consumer: Keep this manual for future reference.
www.sunstonemetalproducts.com
USE & CARE GUIDE
SIDE BURNER
BY SUNSTONE®
ATTENTION: THE SIDE BURNER MUST BE INSTALLED ACCORDING TO THE INSTALLATION
GUIDE. IF YOUR SIDE BURNER INSTALLATION DOES NOT MEET THE BASIC SETUP
INSTRUCTIONS ALL WARRANTIES MAY BE VOID. SEE WARRANTY ON LAST PAGE.

Welcome & Congratulations
Congratulations on your purchase of a new Sunstone Side Burner! We are very proud of our product and
we are completely committed to providing you with the best service possible. Your satisfaction is our #1
priority. Please read this manual carefully to understand all the instructions about how to install, operate
and maintain for optimum performance and longevity. We know you’ll enjoy your new burner and thank
you for choosing our product. We hope you consider us for future purchases.
How to Obtain Service
Before you call
Is there Gas supplied to the Side Burner?
Have you recently refilled the LP Tank?
Please make sure you have the following information:
MODEL NUMBER | DATE OF PURCHASE| INVOICE NUMBER.
KEEP A COPY OF THE PRODUCTS ITEMIZED INVOICE FOR YOUR RECORDS
For warranty service, contact SUNSTONE Customer Service Department at (888)-934-9449 or email
service@sunstonemetalproducts.com.
Must keep copy of your sales slip for proof of purchase.
NAME_________________________________ DATE OF PURCHASE _______________________
ADDRESS_______________________________________________________________________________
MODEL NO_____________________________INVOICE NO_______________________________________
COMPANY THAT YOU PURCHASED FROM ________________________________________________
SUNSTONE METAL PRODUCTS LLC.
16004 Central Commerce Dr, Pflugerville Texas 78660.
Business Hours.
Mon. to Thur. 9:00AM to 4:30PM
Closed Fri/Sat/Sun
Tel: 512-487-5116
Toll Free: 888-934-9449 (Technical Support Line)
Fax: 512-487-7016

ATTENTION: Indicates a potentially hazardous
situation which, if not avoided, may result in minor or
moderate personal injury, or property damage.
WARNING: Indicates an imminently hazardous
situation which, if not avoided, will result in death or
serious injury.
VOLTAGE: Indicates a potentially hazardous
situation which, if not avoided, may result in minor or
moderate electrical shock.
EXPLOSION: Indicates an imminently hazardous
situation which, if not avoided, will result in possible
explosion and cause death or serious injury.
BODILY INJURY: Indicates a potentially hazardous
situation which, if not avoided, may result in minor or
moderate personal injury, or property damage.
HOT SURFACE: Indicates an imminently hazardous
hot surface which, if not avoided, will result in serious
burn or injury.
LIVE CIRCUIT: Indicates a potentially hazard from
Live electrical current that if extreme caution is not
used, may result in minor or moderate personal injury,
or property damage.

START-UP
CHECKLIST
Caution: Never operate the burner unattended.
FIRST TIME STARTUP CHECKLIST
The burner is free of any debris or obstruction.
Installation of the proper gas type and regulator settings.
The proper gas connection is complete.
Minimum clearances are maintained.
All packaging has been removed.
All parts and components are properly installed.
An installer-supplied manual gas shut-off valve is fully accessible.
LP hose is clean and inspected for cuts, wear, abrasions, or leaks.
Replace if necessary, with a suitable UL, ETL or CSA Listed part with
internally threaded connector.
WARNING: If you have a Side Yard Propane Tank, you MUST have additional Medium
Pressure Regulator located at the Burner. If you do not serious bodily harm may result or
damage to the burner and island structure from HIGH Heat extremes.

SPECIFICATIONS – Diagram 1SSB
No.
Name
Qty
Part
No.
1
1SSB Hood
1
SB-HOOD
2
Hood Handle
1
P-HANDLE
3
Grate Grids
1
BURNER-GRAT
4
Burner Assembly
1
BURNER-RING
5
Impulse Igniter
1
IMP-IGNITER
6
Gas Chamber
1
BURNER-GC
7
1SSB Gas Manifold
1
SB-MANIFOLD
8
1SSB Valve
1
SB-VALVE LP/NG
9
Igniter Ring
1
IG-RING
10
Control Knob
1
KNOB-L
11
Control Knob Ring
1
KNOB-RING
12
Igniter Box Cab
1
IG-CAP
13
1SSB Igniter Box
1
IG-BOX
14
1SSB Base
1
SB-BASE
1

SPECIFICATIONS – Diagram 2CSB
No.
Name
Qty
Part
No.
1
2CSB Hood
1
DB-HOOD
2
Hood Handle
1
P-HANDLE
3
Hood Brackets
2
DB-HOOD-BRK
4
Base Brackets
2
2
DB-BASE-BRK
5
Grate Grids
2
BURNER-GRAT
6
Gas Chamber
2
BURNER-GC
7
Impulse Igniter
2
IMP-IGNITER
8
2CSB Gas Manifold
1
SB-VALVE LP/NG
9
Igniter Ring
1
IG-RING
10
2CSB Valve
2
DB-VALVE LP/NG
11
Control Knob Ring
2
KNOB-RING
12
Large Knobs
2
KNOB-L
13
Igniter Box Cap
1
IG-CAP
14
2CSB Igniter Box
1
IG-BOX
15
2CSB Control Panel
1
DB-CT-PAN
16
2CSB Base
1
DB-BASE
2

LOCATING BURNER – Installation Requirements
INSTALLATION REQUIRMENTS
1. COMBUSTABLE MATERIALS: For Wood Framed Island Construction it is Extremely important Not to use any
wood within 24" of Side Burner. Wood frame is fine for Bar/Sink areas and or Storage compartments. If
your island is mostly wood, just substitute for Metal Studs while within the 24" of Side Burner. If the island
structure is against any Combustible Materials - be sure to provide protection and keep a minimum
distance of 12" away.
2. ISLAND VENTILATION: For every Gas-Related appliance Grill or Side Burner you are required to have at
least Two Air-Vents in the Island, within 24" of Appliance. Place Two Vents in Low position within 6" from
base on exterior wall when using Liquid Propane and place Two Vents in High position within 6" below the
counters bottom edge for Natural Gas. Do not Build Enclosure under Side Burners, Side burners are meant
to Free-Hang from counter top surface.
3. GAS SAFETY & ACCESS: For either Natural Gas or Liquid Propane type, it is required you have clear access
to all interior island Gas-Plumbing, we recommend placing one of Sunstone's Single Access Vented Doors.
Also have at least One Safety-Shut Off Valve Present and within easy access, if this appliance is being
installed in a High-Traffic location like for Residential Community, it is important to have installed a Shut-
Off Timer set for Auto-Shut off in 20 Minutes.
3

LOCATING BURNER – Cut-Out Dimensions
Ruby Series Burner Island Cut-Out Dimensions
ITEM NO.
WIDTH
DEPTH
HEIGHT
2CSB – LP/NG
12”
20-1/4”
8”
1SSB – LP/NG
10”
16-1/8”
4”
WARNING: Never build shelf or enclose interior space under the BBQ Cut-Out. The Side Burner is
Self-Rimming and is supported by the top counter surface on the Back and Sides, the front of burner
is designed to Free-Hang. The bottom of Burner needs to be open to allow for proper ventilation.
Burner Cut-Out
Your Side Burner is SELF-RIMMING, meaning the lip of burner rests on top of the counter edge around the
cut-out and is Free-Hanging from counter top. Because of this, there is No Need for any Trim-Kit unlike
other side burners in the market.
1. Maintain 24” Clearance from any Combustible Materials in ANY direction of burner.
2. If any combustible materials within 24” distance, must have Heat Barrier like Jacket, or other Non-
Combustible type like Bricks, Hardy Board, Metal.
3. Orient the burner so the Prevailing winds are not blowing into the burner, this causes flame
disbursement and can extinguish the flame.
4

LOCATING BURNER –Installing in Open Area
Installing Under Structure
ATTENTION: Take special precaution when installing burner in open Breezy area, check the
direction of Prevailing Wind, if back of burner is facing any oncoming wind or breeze, be sure to
protect the back of burner and erect a partition wall.
Windy Area
Positioning your Side Burner in your backyard is more often thought of as how it is pleasing to the eye, but
more important than this is how it functions correctly. Unlike an indoor appliance, your burner must
combat many outside weather influences in all manner of weather-related instances, most severely is
Wind.
1. If wind or breeze is in the direction of back of burner, you must erect partition wall of 8” height. If
this is not done, you must use burner with hood open or when the hood is closed stand near the
area to burner and monitor if the burner overheats.
Overhead Structure Definition:
Structure built above Appliance that is sometimes attached to the home’s exterior outside wall or
roof and there is a Minimum of “Two” adjacent sides which are open to outside exposure.
Clearances to Non-Combustible Construction*:
A minimum of 4” to 6” clearance from the back of the burner to non-combustible construction is
required for the purpose of allowing the lid to open fully. It is desirable to allow at least 6” rear and
side clearance to construction above the cooking surface for counter space.
Enclosed Island Definition:
Any Appliance that is installed into “Enclosed” structure with Two or more sides walled off, either into
an outdoor home’s patio structure, against any home exterior wall or under any Eaves of the home.
5

LOCATING BURNER –Installing Under Structure
6
BODILY INJURY: Failure to maintain required clearances creates a fire hazard that
may result in property damage or serious personal injury.
Clearances to Combustible Construction**:
Minimum of 24” from the sides and rear of burner must be maintained to adjacent vertical combustible
construction, above the counter top level. You should take in account that there is a large volume of heat,
and smoke that will exhaust from the rear of the burner. This may discolor or damage unprotected areas,
do not install under unprotected combustible construction without using a fire safe ventilation system.
A 24” minimum clearance must be maintained under the counter top to combustible construction. The
clearance can be modified by a use of an insulated jacket.
** DEFINITION OF COMBUSTIBLE MATERIAL - Any materials of a building structure or decorative
structure made of wood, compressed paper, plant fibers, vinyl/plastic or other materials that are capable of
transferring heat or being ignited and burned. Such material shall be considered combustible even though flame-
proofed, fire-retardant treated, surface-painted, or plastered.
ATTENTION: All Gas Burner Installations MUST HAVE MINIMUM TWO AIR-FLOW VENTS, either
in ELEVATED POSITION for Natural Gas or LOWERED POSITION for Liquid Propane. Your Warranty may
be VOID if island does not meet basic setup requirements.
WARNING: NEVER BUILD YOUR OUTDOOR KITCHEN ISLAND USING COMBUSTIBLE
MATERIALS, MAINTAIN 24” DISTANCES FROM BURNER. USING A BURNER JACKET IS NOT A SURE
BET TO PROTECT COMBUSTIBLE MATERIALS, NEITHER IS THE USE OF HARDY-BOARD.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali SUNSTONE Bruciatore