1. INTRODUCTION 4
2. SAFETY 5
2.1. Transportation 5
2.2. InstallationLocation 5
2.3. Storage 5
2.4. GeneralSafety 5
2.5. Handling 6
2.6. DamagedBattery 6
2.7. Fire 6
2.8. QualiedPersonnel 6
3. SPECIFICATIONSANDFUNCTIONS 7
3.1. DimensionsandWeigh 7
3.2. Specications 8
3.3. SystemIntroduction 8
4. INSTALLATION 10
4.1. InstallationLocationEnvironment 10
4.2. FrontView 11
4.3. RecommendedDCBreaker 11
4.4. DCCableRequirements 12
4.5. DCCableMounting 12
4.5.1. Material List 12
4.5.2. Steps 12
4.6. Master-SlaveCongurations 13
4.6.1. Single Unit 13
4.6.2. Multi-Units 13
4.7. Communication 15
4.7.1. Denition of Voltage Sampling Connector 15
4.7.2. Denition of Voltage Sampling Connector 16
4.7.3. Port CAN/RS485 and RS232 16
5. BATTERYOPERATIONANDCOMMISSIONING 17
5.1. SystemPowerON 17
5.2. SystemPowerOFF 17

SUNSYNK SSLB1 | Installation Manual3
5.3. SleepandWakeUpFunction 17
5.4. BuzzerFunction 17
5.5. SystemStatusInstruction 17
5.6. LEDTwinkleStatus 18
5.7. SoCIndicator 18
6. MONITORING 19
7. TROUBLESHOOTING 19
8. MAINTENANCE 19
9. WARRANTY 19
9.1. Warrantor 19
9.2. Warrantor 19
9.3. Warrantor 20
9.4. PerformanceWarranty 20
9.5. WarrantyObligations 20
9.6. ProductSuitability 21
9.7. WarrantyTerm 21
9.8. PersonsEntitledtoMakeWarrantyClaims 22
9.9. ClaimNotice 22
9.10. WarrantyLimitations 22
9.10.1. Excluded Warranty Claims 22
9.10.2. Internet Connectivity 23
9.11. General 23

SUNSYNK SSLB1 | Installation Manual4
Thank you for choosing Sunsynk’s energy storage system.
The energy storage module includes lithium-ion rechargeable batteries with 5.12kWh capacity, and the con-
troller enables a central of multiple modules.
This manual provides information regarding safety precautions to prevent possible accidents and how to use
the product. Please read this manual carefully before use for safety and keep this manual handy for refer-
ence.
Some prominent features of this product are:
LongLifeSpan
The battery can be expected to remain serviceable for more than 10 years, considering that it is charged
and discharged once a day at room temperature (25°C).
Stable
Olivine-type lithium iron phosphate batteries with excellent thermal stability and storage characteristics
are used in this product. The module also incorporates a self-monitoring function to detect any abnor-
malities in energy storage.
CompactDesign
The height is nicely designed in 3U, favoring standard industrial applications.
HighScalability
Multiple energy storage modules can be connected in parallel, and the capacity can be customized ac-
cording to the intended use.
1. INTRODUCTION

SUNSYNK SSLB1 | Installation Manual5
Lithium Ferro Phosphate Batteries are classed as Dangerous Goods (DG) Class 9 UN3480. It is forbidden to
subject the product to severe vibration and shock during transportation.
2. SAFETY
Sunsynk's products are designed with full consideration for safety. However, all electrical appliances can be
dangerous if misused; they can cause a re or electric shock, leading to severe injury or death. For your
protection, please read these safety precautions thoroughly.
2.1. Transportation
2.2. Installation Location
2.3. Storage
This battery set is to be installed only indoors.
The product should not be exposed to temperatures above or below the ambient temperature rating
specied in this manual.
The battery should not be installed in direct sunlight.
If the system is not placed to use, the system must be stored appropriately. Otherwise, Sunsynk shall not be
liable for any issues.
It should be stored in 60% SoC status.
It should be stored in a ventilated environment, Temp. < 35°C, RoH <65%.
It should be stored in low-humid ambients.
It should be stored where professionals can monitor it using the monitor system.
2.4. GeneralSafety
DenitionsofSymbols:
Below are symbols used in this manual and the unit.
Please read through the following denitions before reading the manual.
WARNING Ignoring these instructions can lead to a re or electric shock, causing severe
injury or death.
CAUTION Ignoring these instructions can lead to electric shock or other accidents,
causing injury or harm to nearby products.
Wear insulating gloves and protection glasses during installation and connection of the set to prevent
electric shock or other injuries.
Water and/or foreign objects inside the module are not allowed.
The product should not be disassembled. Opening and modifying the set can cause a re or electric
shock.
The cables should not be damaged. If you damage a cable, it can cause a re or electric shock.

SUNSYNK SSLB1 | Installation Manual6
2.5. Handling
The battery should only be used as instructed.
DO NOT use the battery if it seems broken or damaged.
The battery is non-user-serviceable and should not be opened for repair.
Handle the battery with care when installing or transporting it.
Chemicals should not be used to clean the battery.
2.6. DamagedBattery
A damaged battery should not be used and should be returned to Sunsynk or properly discarded via a
recycling facility. Leaking electrolytes can cause skin irruption and chemical burns, so contact should be
avoided.
Eye Flush eyes with plenty of water for at least 15 minutes, occasionally lifting the upper and
lower eyelids. Get medical aid.
Skin Remove contaminated clothes and rinse skin with plenty of water or shower for 15 min-
utes. Get medical aid.
Inhalation Remove from exposure and move to fresh air immediately. Use oxygen if available.
Ingestion Give at least two glasses of milk or water. Induce vomiting unless the patient is uncon-
scious. Call a physician.
The battery should not be punched. DO NOT punch the product
DO NOT touch with wet hands. If you touch the equipment with wet hands, it may cause an electric
shock.
The vent should not be covered. If the vent is covered, the product can overheat and cause a re.
Keep the product away from children and animals.
DO NOT put anything, stand or sit on the battery set. If you put anything on the set, it may fall and cause
injury.
2.7. Fire
A dry agent extinguisher must be available and used if the battery catches re. DO NOT use water. Evacuate
the area and call emergency services. Toxic gas may be produced if the battery catches re.
2.8. QualiedPersonnel
Be aware that only qualied professionals should install the product.
A qualied person is one who has skills and knowledge related to the construction and operation of electri-
cal equipment and has received safety training on the hazards involved. It is authorized to energize, ground,
and tag equipment systems and circuits in accordance with established safety procedures. The inverter and
end-using system may only be commissioned by qualied personnel.

SUNSYNK SSLB1 | Installation Manual7
3. SPECIFICATIONSANDFUNCTIONS
3.1. Dimensions and Weigh
SSLB1 dimensions are presented below. It is well designed for 19-inch cabinet.
PowerLiteLithiumBatterySystemSSLB1
Depth 530mm
Width 440mm
Height 132mm
Weight 48kg

SUNSYNK SSLB1 | Installation Manual8
3.2. Specications
PowerLiteLithiumBatterySystemSSLB1
Cell Type Lithium Ferro Phosphate (LifePO4 or LFP)
Nominal Operating Voltage 51.2V
Nominal Capacity 100Ah / 5.12kWh
Rated DC Output Power 2.56kW
Depth of Discharge (DoD) 100%
Usable Capacity 5.12kWh
Packing 1P16S
IP Rating IP40
Minimum Operating Voltage 44.8V
Maximum Operating Voltage 57.6V
Standard Charging Current 50A
Max. Continuous Charging Current 50A
Standard Discharging Current 50A
Max. Continuous Discharging Current 100A (1C, 25°C ± 2°C)
Max. Pulse Discharging Current 200A (2C, 30S, 25°C ± 2°C SoC≥40%)
Max. DC Charge Power 2.56kW
Max. DC Discharge Power 5kW
Standard Charging Method 0.5C CC to 57.6V, CV at 57.6V till current is 0.05C
Min. Operating Temperature (no derating) Charging: 0°C / Discharging: -20°C
Max. Operating Temperature (no derating) Charging: 50°C / Discharging: 55°C
Operating ROH 20% ~ 80%
Storage Temperature -20 ~ 50°C
Self-discharging rate ≤5% (25°C, 50% SoC)
SoC @ the end of the product life 40%
Insulation Resistance >100MΩ
Voltage Dierence in each module ≤20mV
Inner Resistance of a single Cell 0.34 ± 0.05mΩ (fresh cell 30 ~ 40% SoC)
Altitude Below 2000m
Weight 48kg
Dimensions 440 x 530 x 132mm (not include connector, MSD
and other parts)
Expected Life @ 25°C Greater than 10 years if used as per warranty terms
3.3. SystemIntroduction
SSLB1 Energy Storage System consists of 2 sets of M025100-A modules manufactured by Sunsynk. In each
M025100-A, there are 8 pcs of 100 Ah LFP cells originating from CATL. The overall system also provides a
standard communication port, i.e., CAN and RS485, to monitor the working status and communicate with the
upper machine and the Power Conversion System (PCS) in front. The system schematic drawing is presented
below.

SUNSYNK SSLB1 | Installation Manual9
The batteries are completely compatible with Sunsynk Hybrid Inverters listed below:
SUNSYNK-3.6K-SG01LP1 IP65
SUNSYNK-3.6K-SG02LP1 IP65
SUNSYNK-5.5K-SG01LP1 IP65
SUNSYNK-8.8K-SG02LP1 IP65
SUNSYNK-6K-SG02LP1
SUNSYNK-7.6K-SG02LP1
SUNSYNK-8K-3P-SG02LP1
SUNSYNK-10K-3P-SG02LP1
SUNSYNK-12K-3P-SG02LP1

SUNSYNK SSLB1 | Installation Manual10
4. INSTALLATION
4.1. Installation Location Environment
The location of the battery should be in accordance with the operating temperature range and IP rating
specied in the Specication section of this manual. Although the batteries run at a low temperature, proper
airow around the batteries is recommended.
When installing the set, the following conditions should be met:
Please DO NOT install the product in a completely closed area with no air-conditioning. It can overheat
and cause a re.
DO NOT place in direct sunlight or near a source of heat. This can cause deformation, a breakdown, or a
re. Pay extra attention when you place the system near windows.
The battery should not be set where excessive oil smoke, steam, moisture or dust is contained in the air.
Ensure that the batteries are installed in a clean environment with minimal dust.
Avoid installing the set near the ocean. If unavoidable, appropriate air ltration should be used to
prevent salt air in contact with the batteries.
For proper air circulation to dissipate heat, allow a clearance of approximately 30 cm to the sides of the
battery.
DO NOT install the set near heat sources.
If the batteries are being installed in areas of extreme humidity levels, take the following precautions:
A humidity control agent must be placed inside the enclosure, with controlled airow to expel moist air,
and/or the system can be installed in a proper room with humidity control.
The SSLB1 battery is well-designed to be installed in a 19-inch cabinet. A suitable IP54 or above enclosure
must be used if the battery is installed outdoors.
Altri manuali per SSLB1
2
Indice
Altri manuali SunSynk Accessori per fotocamere

SunSynk
SunSynk SUN-BATT-5.12R Manuale utente

SunSynk
SunSynk SUN-BATT-5.12 Specifiche tecniche

SunSynk
SunSynk SUN-BATT-5.32R Manuale utente

SunSynk
SunSynk SUN-BATT-5.32R Manuale utente

SunSynk
SunSynk SUN-BATT-5.12 Manuale utente

SunSynk
SunSynk L051100-A Manuale utente

SunSynk
SunSynk SSLB1 Manuale utente

SunSynk
SunSynk SSLB1 Manuale utente

SunSynk
SunSynk SSCLK3.1 Manuale utente