Features
Multi-Colors
Color Strobe
Electronic Dimming 0-100%
Built in Microphone
DMX-512 protocol
Master/Slave synchronization

2
Daisy Chain Units Together in DMX Mode
Safety Precautions
To reduce the risk of electrical shock or fire, do not expose this unit to rain or
moisture.
Do not spill water or other liquids into or on to your unit.
Be sure that the local power outlet match that of the required voltage for your
unit.
Do not attempt to operate this unit if the power cord has been frayed or broken.
Do not attempt to remove or break off the ground prong from the electrical
cord. This prong is used to reduce the risk of electrical shock and fire in case of
an internal short.
Disconnect from main power before making any type of connection.
Do not remove the cover under any conditions. There are no user serviceable
parts inside.
Never operate this unit when it’s cover is removed.
Never plug this unit in to a dimmer pack.
Always be sure to mount this unit in an area that will allow proper ventilation.
Allow about 6” (15cm) between this device and a wall.
Do not attempt to operate this unit, if it becomes damaged.
This unit is intended for indoor use only, use of this product outdoors voids all
warranties.
During long periods of non-use, disconnect the unit’s main power.
Always mount this unit in safe and stable matter.
Power-supply cords should be routed so that they are not likely to be walked on
or pinched by items placed upon or against them, paying particular attention to
the point they exit from the unit.
Cleaning -The fixture should be cleaned only as recommended by the
manufacturer. See “Cleaning” for details.
Heat -The appliance should be situated away from heat sources such as
radiators, heat registers, stoves, or other appliances (including amplifiers) that
produce heat.
The fixture should be serviced by qualified service personnel when:
A. The power-supply cord or the plug has been damaged.
B. Objects have fallen, or liquid has been spilled into the appliance.
C. The appliance has been exposed to rain or water.
D. The appliance does not appear to operate normally or exhibits a marked
change in performance.
LED displayer Function
display Function

3
r000 r000-r255,Red color dimming.
G000 G000-G255,Green color dimming.
b000 b000-b255,Blue color dimming.
3 Channel instruction
7 Channel instruction
NO Value Function
CH1 0-255
Master dimming.
CH2 0-255
Master strobe.
CH3 0-255
Function selection,0-50: 7 Channel control,51-100:jump
effect,101-150:gradual change effect,151-200:pulse
change effect,201-255:sound active.
CH4 0-255
Function speed.
CH5 0-255
Red color dimming.
CH6 0-255
Green color dimming.
CH7 0-255
Blue color dimming.
Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses
must be carried out periodically to optimize light output.
1. Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2. Clean the external optics with glass cleaner and a soft cloth every 20 days.
3. Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e.
smoke, fog residue, dust, dew).
Trouble Shooting
Listed below are a few common problems the user may encounter, with solutions.
A001 (001—512),7CH address code.
d001 (001—512),3CH address code.
tb00 (01—99),7 Color jump effect.
Zb00 (01—99), Color pulse change and gradual change effect.
ZH00 (01—99), Color combination effect change.
JLbE (01—99), Sound active.
No
Value
Function
CH1
0-255
R dimming.
CH2
0-255
G dimming.
CH3
0-255
B dimming.

4
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired correctly (pin 3 is
“hot”; on some other DMX devices pin 2 may be ‘hot’). Also, check that all cables
are connected to the right connectors; it does matter which way the inputs and
outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit. If problems are not resolved,
contact your dealer for service.
Specifications
Model:
LT-LP-36P
Working Position: Any safe working position,
Voltage: 90-240V,50H\60Hz
Colors: RGB Color Mixing
LED: 36PCS 3W (RGB).
Len’s angle:25 degree
Channel:3\7ch selectable
Gross Weight: 4.0 Kgs
Dimensions: 240(H) x 240(W) x 310(L) mm
Warranty: 2 Years
Note: All information is subject to change without prior notice.