Systemline S7 Manuale utente

2 Zone NetAmp
Systemline 7 NetAmp, two zone smart multi-room amplifier
Instruction manual
SN1100

Important safety instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarised or grounding-type plug. A polarised plug
has two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specied by the manufacturer
12. Use only with the cart, stand, tripod, bracket or table specied by the manufacturer, or
sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled
or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture,
does not operate normally or has been dropped.
WARNINGS
To reduce the risk of re or electric shock, do not expose this apparatus to rain or moisture.
This apparatus shall not be exposed to dripping or splashing and no objects lled with liquids,
such as vases, shall be placed on the apparatus.
Apparatus with CLASS1 construction shall be connected to a MAINS socket outlet with a
protective earthing connection.

Instructions de sécurité importantes
1. Veuillez lire ces instructions.
2. Veuillez conserver ces instructions.
3. Veuillez prendre connaissance de tous les avertissements.
4. Veuillez suivre toutes les instructions.
5. N’utilisez pas cet appareil a proximite de l’eau.
6. Nettoyez uniquement avec un chion sec.
7. N’obstruez pas les grilles de ventilation. Suivez attentivement les instructions du fabricant lors
de l’installation.
8. N’installez pas cet appareil a proximite d’une source de chaleur telle que des radiateurs, des
bouches d’air chaud, des fours, ou tout autre appareil (y compris des amplicateurs) produisant
de la chaleur.
9. Ne supprimez pas la securite apportee par la prise polarisee ou de type B. Une prise polarisee
possede deux broches, dont une plus large que l’autre. Une prise de type B possede deux broches
et une che terre. La broche la plus large ou la che terre sont la pour votre securite. Si la prise
fournie ne convient pas, adressez-vous a un electricien pour une mise aux normes de votre
installation electrique.
10. Evitez de marcher sur le cordon d’alimentation ou de le pincer, en particulier, a l’extremite du
cordon, de la prise et a la sortie de l’appareil.
11. Utilisez uniquement des accessoires species par le fabricant.
12. Utilisez uniquement les chariots, pieds, tripodes, supports ou les tables recommandes par
le fabricant ou vendus avec l’appareil. Si vous utilisez un chariot, faites tres attention lors du
transport de l’appareil et evitez de le faire tomber pour ne pas vous blesser.
13. Debranchez cet appareil en cas d’orage ou lorsque vous ne vous en servez pas pendant une
periode prolongee.
14. Pour toute reparation, adressez-vous a un professionnel. Faites reparer cet appareil pour des
dommages de n’importe quelle nature : cordon d’alimentation abime, liquide ou objet introduit
dans l’appareil, exposition a la pluie ou a l’humidite, fonctionnement inhabituel, chutes diverses.
AVERTISSEMENT
An de diminuer les risques d’incendie ou de choc electrique, conservez cet appareil a l’abri de la
pluie et de l’humidite.
Evitez toute eclaboussure et ne posez pas d’objets contenant des liquides, comme des vases, sur
cet appareil.
L’appareil de construction de CLASS1 doit être connecté à une prise secteur dotée d’une
protection par mise à la terre.

Contents
1.0 Pack contents 5
2.0 NetAmp mounting 5
2.1 HomeNet cabinet 5
2.2 Standard cabinet 5
2.3 Wall 5
2.4 19” rack adaptor 5
3.0 NetAmp connections 6
3.1 Top face 6
3.2 Front face 7
3.3 Bottom face 7
4.0 NetAmp room connectivity 8
4.1 Connecting a standard zone 8
5.0 Using a separate power amplier 9
6.0 NetAmp source connectivity 10
6.1 Connecting the S7 NetServer 10
6.2 Connecting analogue or optical digital inputs 1 & 2 11
6.3 Connecting analogue or optical digital inputs 3 & 3A 11
7.0 NetAmp conguration 12
7.1 Overview 13
7.2 Factory Setup 13
7.3 Network Setup 13
7.4 Source Setup 13
7.4.1 Source 1 & 2 conguration 13
7.4.2 Source 3 and 3A conguration 14
7.5 Zone 1 Setup 16
7.6 Zone 2 Setup 17
8.0 KPS-11 keypad installation and conguration 18
8.1 Connecting and installing the keypads 18
8.2 Addressing keypads 18
8.3 Conguring keypads 19
8.3.1 Default conguration 19
8.3.2 NetMusic 1 conguration 20
8.3.3 NetMusic 2 conguration 20
9.0 Local Input Module (LIM) installation and conguration 21
9.1 LIM Connections 21
9.2 IR receiver and IR codes 21
9.3 LIM conguration and switching options 22
9.4 Manual or auto-switching of analogue and digital sources 22

5
1.0 Pack contents
1.1 NetAmp x 1
1.2 Mounting brackets x 2
1.3 Bracket xing screws x 4
1.4 IMO speaker connectors x 4
1.5 HomeNet cabinet xing screws x 4
1.6 Right angled mains cable
1.7 USB A-B cables (0.5m) x 2
1.8 Quick start instruction manual x 1
2.0 NetAmp mounting
NetAmp can be mounted in an S7 HomeNet cabinet, an S7 standard cabinet, on a 19” rack
adaptor, on a shelf or on a wall.
2.1 HomeNet cabinet
Place the NetAmp on the swing frame in the correct location and use the four large diameter
xing screws (1.5) to mount the NetAmp onto the frame, using the threaded holes on the front
face of the NetAmp.
2.2 Standard cabinet
Fix the mounting brackets (1.2) onto the sides of the NetAmp using the four smaller diameter
bracket xing screws (1.3).
Fix the NetAmp to the back panel of the cabinet, using the screws supplied with the cabinet to
secure the NetAmp brackets in place.
2.3 Wall
Fix the mounting brackets (1.2) onto the sides of the NetAmp using the four smaller diameter
bracket xing screws (1.3).
Fix the NetAmp to the wall using suitable xing screws and solid plugs if needed. These are not
supplied.
2.4 19” rack adaptor
Fix the mounting brackets (1.2) onto the sides of the NetAmp using the four smaller diameter
bracket xing screws (1.3).
Fix the NetAmp to the rack adaptor using the screws provided.

46 556
12 2 33
6
3.0 NetAmp connections
3.1 Top face
1. Ethernet RJ45 for Local Area Network
2. Keypad RJ45 for KPS-11 or KPS-3 S7 keypads
3. Local RJ45 for S7 Local Input Modules (LIM)
4. 12V trigger mono 3.5 jack for auto switching power ampliers
5. Stereo speaker outputs
6. Pre-amp outputs, stereo phono

1
6
7
2
3
4
5
1
7
3.2 Front face
1. Status display
2. Select button – changes display information
3. Standby button
4. Reset button
5. USB inputs from S7 server
6. Analogue 3.5mm stereo or Digital mini TOSLINK inputs
7. Analogue 3.5mm stereo or Digital mini TOSLINK outputs
3.3 Bottom face
1. Mains input, 110-240V AC

8
4.0 NetAmp room connectivity
4.1 Connecting a standard zone
Run speaker cable from the NetAmp to the stereo speakers in the zone. QED 79 strand or QED Pro
16/2 or 16/4 is recommended.
Use Cat5 or Cat6 from the NetAmp to a KPS-11 or KPS-3 keypad.
Use Cat5 or Cat6 from the NetAmp to an RJ45 data socket for the local input audio.
Use a standard Cat5 or Cat6 data patch cable to connect the NetAmp ethernet socket to a suitable
network switch or broadband router.

9
5.0 Using a separate power amplier
If you wish to use a separate power amplier for a zone, then use a quality audio interconnect
cable such as the QED Performance Audio (phono to phono) to connect the Pre-Output from the
NetAmp into the power amplier input. NetAmp also supports 12V trigger, which can switch on a
power amp when the zone becomes active. Use a mono or stereo jack to jack cable to connect the
12V trigger if your power amplier supports this.
The Systemline 7 NetPower supports 12V trigger and delivers 100 Watts per channel.

10
6.0 NetAmp source connectivity
6.1 Connecting the S7 NetServer
Each NetAmp requires two USB connections from the server in order for both zones to receive
independent music. Use a USB A to B type cable to connect the NetAmp USB input to the server.
This is often done via a USB hub as shown which allows the server to connect up to 24 S7 zones.
If both USB inputs are used then they are allocated as follows:
USB input 3 – Zone B
USB input 3A – Zone A
If zone B is used as a sub-zone, then a single USB connection to the server can be used to share
this input across both zones. This is allocated as follows:
USB input 3 – Zone A and B shared
USB input 3A – Not used
NetAmp will present an optical output for USB input 3, allowing you to share this across more
zones by linking into more NetAmps. This is only available for USB 3. Use a mini Toslink to mini
Toslink cable.
Altri manuali per S7
1
Indice
Altri manuali Systemline Amplificatore

Systemline
Systemline SN1210 Manuale utente

Systemline
Systemline ZAM40 Istruzioni per l'installazione e il funzionamento

Systemline
Systemline MRA-2 Manuale utente

Systemline
Systemline S7 NetConnect Manuale di programmazione

Systemline
Systemline E50w Manuale utente

Systemline
Systemline SE0512 Manuale utente

Systemline
Systemline S7 NetAmp Manuale utente

Systemline
Systemline E50 Manuale utente

Systemline
Systemline S7 Manuale utente

Systemline
Systemline SN1210 Manuale di programmazione