T-Verter E2 Series Manuale utente

E2 Adjustable Speed Driver
Microprocessor Controlled
IGBT Drive
Inverter Motor Speed Regulator
Operating Manual
High Performance Adjustable Speed Micro Drives
E2 Series
110V 0.2~0.75KW
( 0.53~1.6KVA )
220V 0.2~2.2KW
( 0.53~4.0KVA )
440V 0.75~2.2KW
( 1.7~4.0KVA )
TAIAN

Operations Manual
Table of Contents
Foreword......................................................................................1
Chapter 1 Safety Precautions
1. Precautions for Operation .......................................3
2. Environmental Precautions .....................................6
Chapter 2 Hardware Instruction and Installation
1. Operational Environment.........................................7
2. Sample Model No. Identification..............................8
3. Specifications ..........................................................9
4. Wiring ....................................................................15
5. Dimensions & Location of terminal block ..............18
Chapter 3 Software Index
1. Keypad Operating Instructions..............................27
2. Parameters List .....................................................28
3. Parameter Function Description............................29
4. Malfunction Indication and Countermeasure.........41
5. General Malfunction Examination Method ............44
Chapter 4 Trouble Shooting Procedure
1. Flow Chart………………………………………… 45
2. Maintenance Examination ……………………… 53

1
1. Foreword
To fully employ all functions of this AC Drive, and to ensure the safety for its users, please read
through this operations manual in detail. Should you have any further questions, please feel free to
contact your local distributor or regional representative.
※Please use Precaution with this product
The AC Drive is a power electronic device. For safety reasons, please read carefully those
paragraphs with “WARNING” or “CAUTION” symbols. They are important safety precautions to be
aware of while transporting, installation, operating or examining the AC drive. Please follow these
precautions to ensure your safety.
WARNING Personnel injury may be resulted by improper operation.
CAUTION The AC Drive or mechanical system may be damaged by improper operation.
WARNING
zDo not touch the PCB or components on the PCB right after turning off the power before the
charging indicator went off.
zDo not attempt to wire circuitry while power is on. Do not attempt to examine the components
and signals on the PCB while the inverter operating.
zDo not attempt to disassemble or modify internal circuitry, wiring, or components of the
inverter.
zThe grounding terminal of the inverter must be grounded properly with 200V class type III
standard.
zThis is a product of the restricted sales distribution class according to EN61800-3.
In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
CAUTION
zDo not attempt to perform dielectric strength test to internal components of the inverter. There
are sensitive semiconductor-devices vulnerable to high voltage in the inverter.
zDo not connect the output terminals: T1 (U), T2 (V), and T3 (W) to AC power input
zThe CMOS IC on the primary PCB of the inverter is vulnerable to static electrical charges. Do
not contact the primary PCB of the inverter.

2
2. Examination before installation
Every inverter has been fully tested and examined before shipment. Please carry out the following
examination procedures after unpacking your AC inverter.
zCheck to see if the model number of the AC inverter matches the model number of the AC
inverter that you ordered.
zCheck to see whether any damage occurred to the AC inverter during shipment. Do not
connect the AC inverter to the power supply if there is any sign of damage.
Report this to a regional sale representative if you find any abnormal condition as mentioned
above.

3
Chapter 1: Safety Precaution
1. Precautions for operation
Before turning ON power
CAUTION
Choose the appropriate power source with correct voltage settings for the input voltage
specification of the AC inverter.
WARNING
Special care must be taken while wiring the primary circuitry panel. The L1 and L2
terminal must be connected to the input power source and must not be mistakenly
connected to T1, T2 or T3 out put terminals. This may damage the inverter when the
power is turned on.
CAUTION
zDo not attempt to transport the inverter by the front of the cover. Securely hold the
inverter by the heat-sink mounting chassis to prevent the inverter from falling, this
may cause personnel injury or damage to the inverter itself.
zInstall the inverter onto a firm metal base plate or another non-flammable type
material. Do not install the inverter onto or nearby any flammable material.
zAn additional cooling fan may need to be installed if several inverters are installed
into one control panel. The inside temperature inside an enclosed panel should be
below 40 degrees to avoid overheating.
zTurn off the power supply before proceeding to remove or perform any work on any
panel. Carry out installation procedures according to instructions given in order to
avoid a situation resulting in an operational malfunction.
zSuitable for use on a circuit capable of delivering not more than 5000 RMS
symmetrical amperes. 240 Volts maximum.
zThis product is not provided with over speed protection.
zOnly intended for use in a pollution degree 2 macro environment or equivalent

4
When power is applied
WARNING
zDo not attempt to install or remove input or out put connectors of inverter when the
power supply is turned on. Otherwise, the inverter may be damaged due to the
surge peak caused by the insertion or removal of power.
zWhen momentary power loss is longer than 2 seconds (the large of horse power,
the longer of time), the inverter does not have enough storage power to control the
circuit; Therefore, when power is regenerated, the operation of the inverter is
based on the setup of F_10 and the condition of external switch, this is considered
to be「restart」in the following paragraphs.
zWhen the momentary power loss is short, the inverter still has enough storage
power to control the circuit; therefore, when power is regenerated, the inverter will
automatically start operation again depends on the setup of F_23.
When restart the inverter, the operation of the inverter is based on the setup of
F_10 and the condition of external switch (FWD/REV button). Attention: the
restart operation is irrelevant with F_23/F_24.
(1) When F_10=0, the inverter will not start after restart.
(2) When F_10=1 and the external switch (FWD/REV button) is OFF, the inverter
will not start after restart.
(3) When F_10=1 and the external switch (FWD/REV button) is ON, the inverter
will start automatically after restart. Attention: Base on safety reason, please
turn off the external switch (FWD/REV button) after power loss to avoid
possible damage to the machine and the human body after sudden
regeneration of power.

5
Under Operation
WARNING
Do not use a separate device to switch ON or OFF motor during operation. Otherwise,
the inverter may experience an over-current breakdown.
WARNING
zDo not remove the front cover of the inverter when the power is ON to avoid
personnel injury caused by electrical shock.
zWhen the automatic restart function is enabled, the motor and machinery will be
restarted automatically.
CAUTION
zDo not touch the heat-sink base during operation.
zThe inverter can be easily operated from a low-speed to high-speed range. Please
reconfirm the operating range of motor and the machinery you are controlling.
zDo not examining the signals on the PCB of the inverter when it is under operation.
zAll inverters are properly adjusted and set before delivery.
CAUTION
Do not proceed with disassemble or examination procedure before ensuring that the
power is off and the Power LED extinguished.
When performing an examination or maintenance
CAUTION
Inverter environment should be within temp: –10OC ~ +40OC, humidity under 95% RH
without condensing.
CAUTION
After the removal of shield sticker, the environment temperature should be
within –10OC ~ +50OC and humidity under 95% RH without condensing. Besides, the
inverter should be free from water dripping or metal dust.

6
2. Precautions of operation environment
Avoid any direct sunlight Keep away from
corrosive gas or liquid Keep away from oil
grease and gas
Keep away from salty
environments
Keep away from rain or
where dripping water may
get into the inverter
Avoid metal dust and
dusty environments
Avoid massive vibration
Avoid excessive direct heat
Avoid where
environmental
temperatures are too high
K
eep away
f
rom
h
i
g
h
electrical-magnetic waves
or ultra-high waves. Keep away from
radioactive matter Keep away from
flammable material
oil

7
Chapter 2: Hardware Instructions and Installation
1. Operational Environment
The installation site of the inverter is very important. It relates directly to the functionality and the life
span of your inverter. Please carefully choose the installation site to meet the following
requirements:
zMount the unit vertically
zEnvironment temperature: -10OC ~ +40OC (without shield sticker: -10OC ~ +50OC)
zAvoid placing close to any heating equipment
zAvoid water dripping or humid environment
zAvoid direct sunlight
zAvoid oil or salty corrosive gas
zAvoid contacting corrosive liquid or gas
zPrevent foreign dusts, flocks, or metal scraps from entering interior
zAvoid electric-magnetic interference (soldering or power machinery)
zAvoid vibration, if vibration cannot be avoided, an anti-rattle mounting device should be
installed to reduce vibration.
zIf the inverter is installed in an enclosed control panel, please remove the shield sticker located
at the top of the inverter. This will allow additional airflow and cooling.
zFor proper Installation of the inverter you must place the front side of the inverter facing front
and the top of the inverter in the up direction for better heat dissipation.
zInstallation must be compliant to the following requirements.
External Fan Placement needs to be over the top of the inverter
Correct Alignment Wrong Alignment Correct Alignment Wrong Alignment

8
Note: Maximum temperature in the enclosure 50 ℃
2. Sample Model No. Identification
Inverter Model ⇓MODEL: E2-201-M1F
Input Power Rating ⇓I/P: AC 1PH 200 ~ 240V 50/60 Hz
Output Rating ⇓O/P: AC 3PH 0 ~ 240V 1 Hp 4.2 Amps
E2 - 2 01 - M 1 F N4
Series Power
Voltage Horse Power
Rated Model
Type Power
Supply Filter
Option Enclosure
Type
Ventilation & Installation
Direction
Front View
1 : 110V
2 : 220V
4 : 440V
P2 : 0.25 Hp
P5 : 0.5 Hp
01 : 1 Hp
02 : 2 Hp
03 : 3 Hp
M : CPU Version
V1.6
H : CPU Version
V1.9 or above
1 : Single
Phase
3 : Three
Phase
Blank :
Single or
Three
Phase
F :
with filter
Blank :
without filter
N4S :
meet IP65/NEMA4
Standard with
Switch
N4 :
meet IP65/NEMA4
Standard without
Switch
Blank : IP20
Questo manuale è adatto per i seguenti modelli
11