Tactical TPS24-3DC Manuale utente

DESIGNED & MANUFACTURED
24Vdc 3A & 6APower Series
Installation Manual
MODELS :
TPS24-3DC
TPS24-3DC-B
TPS24-3DC-ME
TPS24-3DC-MED10
TPS24-3DC-MED20
TPS24-6DC
TPS24-6DC-B
TPS24-6DC-ME
TPS24-6DC-MED10
TPS24-6DC-MED20
© 2012 The contents of
this manual are copyright
and may not be reproduced
without the written
permission of Tactical
Power Producst Pty Ltd.

DANGER
HIGH VOLTAGE
CAUTION
Dangerous Voltages Inside !
No user serviceable parts inside
Do not remove covers
Dangerous internal voltages exceeding
400 Volts - DO NOT REMOVE COVERS !
Equipment must be installed & serviced
by suitably qualied service personnel in
a restricted access area.
General
These power supplies are designed for indoor use only.
TPS24-DC Series models are high performance, extremely low noise, Dual Channel Switch Mode power supplies offering 24Vdc at 3A or
24Vdc 6A (model dependant).
When operating from mains, these models provide an output of 24Vdc ( to power connected equipment) and are configured with a
separate 27.6Vdc battery charging channel. Available battery charge current is 700ma @ 27.6Vdc (approx) for TPS24-3DC Models (total
output 3.7A) & 1.4A @ 27.6Vdc (approx) for TPS24-6DC Models (total output 7.4A) In the event of mains failure, battery voltage is clamped
to 24Vdc and instantaneously powers the load. When the mains voltage is restored, batteries are disconnected from the load and
recharging commences automatically.
Output short-circuit and overload protection are provided . Removal of the fault / short circuit condition will return the power supply
to normal operation ( Auto-Reset ).
Model Variants
TPS24-3DC Single 3A Output - Supply only - no cabinet (273L x 145W x 80H )
TPS24-3DC-B Single 3A Output - Medium steel enclosure ( 340W x 436H x 145D mm )
TPS24-3DC-ME Single 3A Output - Large steel enclosure ( 482W x 470H x 185D mm )
TPS24-3DC-MED10 10 x 300mA Outputs - Large steel enclosure ( 482W x 470H x 185D mm )
TPS24-3DC-MED20 20 x 150mA Outputs - Large steel enclosure ( 482W x 470H x 185D mm )
TPS24-6DC Single 6A Output - Supply only - no cabinet (273L x 145W x 80H )
TPS24-6DC-B Single 6A Output - Medium steel enclosure ( 340W x 436H x 145D mm )
TPS24-6DC-ME Single 6A Output - Large steel enclosure ( 482W x 470H x 185D mm )
TPS24-6DC-MED10 10 x 600mA Outputs - Large steel enclosure ( 482W x 470H x 185D mm )
TPS24-6DC-MED20 20 x 300mA Outputs - Large steel enclosure ( 482W x 470H x 185D mm )
Connection
Single Output Models Multiple Output Models
10-way removable terminal block provides the following:
( See over the page for a layout )
* 24Vdc Output
* 27.6Vdc Output for SLA (Sealed Lead Acid) Batteries
* Battery Test load (not used on this model)
* AC OK Relay Output ( SPST )
* Battery Fault/Low Battery Relay Output ( SPST )
24Vdc Output is via individually fused outputs ( 10 or 20 )
10-way removable terminal block provides the following:
( See over the page for a layout )
* 27.6Vdc Output for SLA (Sealed Lead Acid) Batteries
* Battery Test load (not used on this model)
* AC OK Relay Output ( SPST )
* Battery Fault/Low Battery Relay Output ( SPST )
Caution when handling batteries:
Before connecting two 12V SLA batteries in series to this power supply, ensure both are fully charged to 13.8V, this will ensure the batteries are charged
evenly via the 27.6v charging circuit. Excercise care when terminating and connecting batteries. Mishandling or short circuit of SLA batteries can cause
severe damage, burns and fire.
TPS24-DCSeries_Rev K.pdf www.tacpower..com.au

DESIGNED & MANUFACTURED
O
Rear View
P
AOutput Terminals ( Multi Output models only ) BPDM Input ( Multi Output models only ) - “ I ” below
CIndividual Circuit Status LEDs ( Multi Output Models ) DIndividual Circuit Fuses ( Multi Output models only )
EAC Mains OK Output ( COM / NC ) FBattery Low / Fault Output ( COM / NC )
GNot used in this model H- Battery + (Connect Sealed Lead Acid Batteries)
I- Output 24Vdc + ( Connect to load or PDM ) JNot used in this model
KBattery Test Fail LED ( Red ON = Fail ) LBattery Fuse Fail LED ( Red ON = Fail )
MAC Mains OK LED ( Green ON = OK ) NReverse Battery LED ( Red ON = Fail )
O240V IEC Mains Socket PCompliance / Date of Manufacture Label
LAYOUT
www.tacpower.com.au
TPS24-DCSeries_Rev K.pdf
E F G H I
J K L
M N
A
B
C
D
Multi-Output Models TPS24-6DC Module Face
( e.g. TPS24-6DC-MED10 )

Designed & Manufactured
Specications : ( In the interests of product improvement, Tactical reserves the right to change specifications without notice)
Tel: 1300-822-769 PO Box 90 Kurrajong NSW 2758 sales@tacpower.com.au
Securing Your Power Needs ®
Now and into the Future . . .
www.tacpower.com.
3DC 3DC-B 3DC-ME 3DC-
MED10
3DC-
MED20 6DC 6DC-B 6DC-ME 6DC-
MED10
6DC-
MED20
Full Model Number TPS24-3DC TPS24-
3DC-B
TPS24-3DC-
ME
TPS24-3DC-
MED10
TPS24-3DC-
MED20 TPS24-6DC TPS24-
6DC-B
TPS24-6DC-
ME
TPS24-6DC-
MED10
TPS24-6DC-
MED20
Output Voltage 24Vdc
Output Current 3A 6A
Output Channels 1 10 20 1 10 20
Output per Channel 3A 300mA 150mA 6A 600mA 300mA
Input Voltage 240 V ac ( 215V - 255V ) 50Hz
Input Current 0.8A at full load 1.6A at full load
Input In-Rush <20A ( 25˚C cold start up )
Battery Charger 27.6Vdc / 0.7A 27.6Vdc / 1.4A
Low Battery Indicator 1 x SPST Relay & Red LED
AC OK Indicator 1 x SPST Relay & Green LED
Weight < 2Kg < 5Kg < 12Kg < 2Kg < 5Kg < 12Kg
Dimensions (mm) 273L x 145W
x 80H
340W x 436H
x 145D 482W x 470H x 185D 273L x 145W
x 80H
340W x 436H
x 145D 482W x 470H x 185D
Efficiency 80% Typical
Overload Protection Constant current limiting, short circuit shutdown, auto recovery
Load Regulation < 1% from open to full load
Line Regulation < 0.2%
Output Ripple <50 mVp-p @ full load
Working Temperature 0 - 45 ˚ C
Revision K
Safety Standards AS NZS 60950.1:2003
EMC Standards AS / NZS CISPR 11:2004 Class B (Conducted & Radiated)
24Vdc
3A & 6A Series
Questo manuale è adatto per i seguenti modelli