TCS ASX1300 -0010 Series Manuale utente

Product information
Audio front door station series
ASX1300x-0010
for surface-mount

2

3
Table of contents
Scope of delivery............................................................................................................ 4
introduction.................................................................................................................... 4
Notes on this product information .................................................................................................................................4
Used symbols and warning notices ..............................................................................................................................4
Further used symbols and designations.......................................................................................................................4
Safety instructions......................................................................................................... 5
General safety regulations............................................................................................................................................5
requirements to protect against lightning......................................................................................................................5
Product description ....................................................................................................... 6
Intended use .................................................................................................................................................................6
Short description...........................................................................................................................................................6
Device overview............................................................................................................................................................7
Technical data...............................................................................................................................................................7
Mounting and installation .............................................................................................. 8
Installation.....................................................................................................................................................................8
Connecting the lines ...................................................................................................................................................11
Example circuit............................................................................................................................................................12
Initial operation............................................................................................................ 13
Settings .......................................................................................................................................................................13
Programming the bell buttons ..................................................................................... 14
Basic principle.............................................................................................................................................................14
Cleaning........................................................................................................................ 15
Conformity.................................................................................................................... 15
Information on disposal ............................................................................................... 16
Warranty....................................................................................................................... 16
Spare parts, accessory................................................................................................ 16
Service.......................................................................................................................... 16

4
Scope of delivery
1 x compact front door station ASX1300x-0010
1 x slot screwdriver
1 x hexagon ballpoint screwdriver with 2.5 mm wrench size
1 x special wrench for exchanging nameplates
nameplates empty
product information
Introduction
Notes on this product information
This product information refers exclusively to qualified electricians.
The product information contains important notes on intended use, installation and initial operation.
Please, keep the product information at a suitable place, where it is easily accessible for maintenance
and repair reasons.
All product information are available in the download area at www.tcsag.de .
Further information you'll find in our system manual, available in the download area at www.tcsag.de
.
Used symbols and warning notices
Symbol signal word Explanation
DANGER! The signal word describes an endangering with a high level of risk. Failure to observe
this warning will result in death or very serious injury.
WARNING! The signal word describes an endangering with a medium level of risk. Failure to ob-
serve this warning could result in death or very serious injury.
CAUTION! The signal word describes an endangering with a low level of risk. Failure to observe
this warning could result in a minor or moderate injury.
ATTEN-
TION! The signal word indicates that damages on equipment, environment and property can
occur.
Further used symbols and designations
important note or important information
►Step
cross reference For further information on this topic, see source
list, list entry 1 level
– list, list entry 2 level
a) Explanation

5
Safety instructions
General safety regulations
Assembly, installation, commissioning and repair of electronic devices must be carried out by
qualified electricians.
Observe the latest regulations and standards for system installations.
WARNING! Danger to life due to electric shock
Observe the safety regulations according to DIN VDE 0100, when working on main power
connections of 230 V.
When installing TCS:BUS systems the general safety regulations for telecommunication sys-
tems according to VDE 0800 must be observed. Inter alia:
separated cable routing of high and low voltage lines,
minimum distance of 10 cm in case of a common cable routing,
use of separators between high and low voltage lines within shared cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
already existing lines (modernisation) with deviating cross-sections can be used in compli-
ance with the loop resistance.
Requirements to protect against lightning
CAUTION! Device damage due to over-voltage
By suitable lightning protection measures it has to be ensured that the electric voltage of 32 V
DC at each connection is not to be exceeded.

6
Product description
Intended use
The ASX1300x-0010 is audio front door station series with compact design, suitable for the usage in the
outdoor and indoor area.
The series is suitable for surface-mount.
For applications, which differ from the intended use or goes beyond it, the manufacturer ac-
cepts no liability.
Short description
for up to 6 flats
nameplate size 31 mm x 12 mm (W x H)
housing made of robust aluminium
bell push-button made of plastics
per bell push-button 2 indoor stations can be allocated
durable and energy-saving nameplate illumination
shatter-proof nameplate glass
acknowledgement tone when pressing the bell button
conversation time ex works: 56 seconds / can be adjusted with configuration software configoTM
any bell push-button can be used to switch the light, light symbol enclosed
volume and microphone sensitivity can be adjusted manually
door call standby time (to control the short-term memory in indoor stations) ex works: 56 seconds /
can be adjusted with configuration software configoTM
voice connection in door call standby time / can be adjusted with configuration software configoTM

7
Device overview
1 upper part of the housing 7 attachment hole
2 loudspeaker 8 rear panel
3 cable gland 9 LED nameplate illumination
4 volume control loudspeaker 10 microphone
5 connection terminal (a, b and P) 11 fitting upper part of the housing
6 volume control microphone 12 bell button with labelling
Technical data
supply voltage +24 V ± 8 % (power supply and control unit)
input current in resting position 3-wire operation: I(a) = 0.4 mA, I(P) = 9.13 mA
maximum input current: I(amax) = 17 mA , I(Pmax) = 25 mA
housing aluminium, anodised nature
nameplate glass acrylic glass
dimensions (H x W x D) from 99 to 179 x 50 x 16 mm
weight (in g) 107 g (ASX13002-0010)
acceptable ambient temperature -25 °C … + 55 °C
degree of protection IP44
3-wire technology necessary!

8
Mounting and installation
Installation
CAUTION! Damages on the device
Do not seal the device with silicon under any circumstances! Condensed water must be able
to escape and evaporate.
Installation site
For an optimal operation we recommend a mounting height of
1.50 m (Fig. 1).
Observe to keep a free space of at least 10 cm below
the device when installing it, to ensure a proper func-
tion of the microphone.
Fig. 1: Mounting height
Opening the device
The upper part of the housing is screwed together with the
rear panel via a hexagon socket screw (Fig. 2).
►Loosen the hexagon screw (1) with the allen key (2) for
around 2 mm.
Do not unscrew the hexagon screw.
►Pull off the upper part of the housing from the rear panel
(3).
►Remove the upper part of the housing upwards (4).
►Pull off the cable of the loudspeaker from the socket.
►Place the upper part of the housing on a clean and dry sur-
face.
Fig. 2: Opening the front door station

9
A
ssembling the rear pane
l
►Guide the connection cable (3) through the cable gland (1)
of the rear panel (Fig. 3).
►Fix the rear panel with 2 screws (2) to the wall.
Observe the installation position of the rear panel.
The connection terminal must face upwards.
Ensure that the cables from the rear panel do not get
clamped.
Fig. 3: Assembling the rear panel
Connecting the lines
►Strip the lines.
►Connect the lines (a, b and P) according to the labelling (1)
(Fig. 4).
Observe the example circuit on page 12.
2-wire technology (special operation)
Using this operation mode only 1 front door station can be
connected.
Bridge the terminals a and P for power supply.
The front door station does not work if the bridge is
connected to the b-wire.
Fig. 4: Connecting the lines
Fig. 5: 2-wire technology (special operation)

10
Closing the device
►Plug the connector of the loudspeaker cable (1) into the
appropriate socket (Fig. 6).
►Put on the upper part of the housing (2) onto the rear panel
(Fig. 7).
►Turn down the upper part of the housing onto the rear panel
(3).
►Fix the upper part of the housing to the rear panel with the
hexagon socket screw.
Fig. 6: Connecting the loudspeaker
Fig. 7: Closing the device
Indice
Altri manuali TCS Sistema di interfono

TCS
TCS IVW2211-0218 Manuale utente

TCS
TCS ISW3330 Manuale utente

TCS
TCS AVD Series Manuale utente

TCS
TCS AMI1090 Series Manuale utente

TCS
TCS ISW3330 Manuale utente

TCS
TCS IVX9001-0140 Manuale utente

TCS
TCS Tasta Series Manuale utente

TCS
TCS ISH3230-0140 Manuale utente

TCS
TCS IVW3012-0110 Manuale utente

TCS
TCS ISH3022-0140 Manuale utente

TCS
TCS Carus Adapto Manuale utente

TCS
TCS IVH3222 Manuale utente

TCS
TCS ISW3230-0140 Manuale utente

TCS
TCS SKYLINE:TEN BASIC Manuale utente

TCS
TCS IMM2300 Manuale utente

TCS
TCS ISW3130 Manuale utente

TCS
TCS ISH3022 Manuale utente

TCS
TCS ISW3230-0140 Manuale utente

TCS
TCS AMI Series Manuale utente

TCS
TCS Carus Adapto Manuale utente