TEA TURTLE 801589 Manuale utente

PROFESSIONAL AIR MONITORING SYSTEMS
TURTLE
COD. 801589
PM10 - PM2,5 - TEMPERATURE- HUMIDITY
USER’S MANUAL
Ed. 19102022 v.2.0
www.tea-group.it

2
Table of Contents
• 1. INTENDED PURPOSE, 2. CLASSIFICATION OF EQUIPMENT, 3 . WARNINGS..............................................2
• 4. CONTENTS OF THE BOX …………………………………………………………..…………….………………….…………………..3
• 5. INSTRUCTIONS FOR PLACEMENT AND SETUP .....................................................................................4
• 6. INSTRUCTIONS FOR INSTALLATION AND STARTING............................................................................5
• 7. TECHNICAL SPECIFICATIONS, 8. MAINTENANCE, 9. GUARANTEE .......................................................6
• 10. OPTIONAL PARTS..............................................................................................................................7
www.tea-group.it
1. Intended Purpose
2. Classicaon of Equipment
ABS Enclosure (Protecon of Harmful Ingress of Water) IP44 Classicaon (outdoor use)
Oponal Power Supply (as backup to photovoltaic panel) IP20 Classicaon (indoor use)
Mode of Operaon Connuous
3. Warnings
General Warnings
CAUTION: To avoid the risk of electric shock.
CAUTION: No modicaon of this equipment is allowed.
CAUTION: Do not restrict the air ow of the product.
CAUTION: Not to be used by persons (including children) with reduced physical, sensory or mental capabilies, or lack of ex-
perience and knowledge, unless they have been given supervision or instrucon.
Children should be supervised to ensure that they do not play with the appliance.
CAUTION: Avoid deploying the device in a soot environment, with excessive dust parcles or high humidity.
CAUTION: The module should avoid contact with organic solvents (including silica gel and other adhesives), coangs,
pharmaceucals, oils and high-concentraon gases.
CAUTION: The module cannot be used in the environment containing corrosive gas for a long me. Corrosive gas will
damage the sensor.
CAUTION: Do not use this module in systems involving personal safety.
The Turtle Staon is an outdoor air quality sensor unit. It was developed to be a robust and safe device for meas-
uring air quality and detecon of ne parculate maer. Collected data is sent via WiFi into the residenal home
network and transmied through the internet to the main servers. The Turtle Monitoring Staon was developed
in collaboraon with the naonal research council of Italy.
Please read and follow all instrucons in this manual with great care.

3
Turtle Staon
4. Contents of the box
-open and unpack with care
-check contents for transport damages
-read the whole manual before starng sensor
801589
QR code with link to onboarding guide
Oponal Charger
www.tea-group.it
Items shown here may dier from the original provided in this package. Due to the producon process the
appearance and colors of images in the manual may dier within reasonable boundaries from the original .
Thank you for purchasing a TEA product!
To see the guide for onboarding and the
digital version of the user‘s manual,
please scan the QR code or use the link:
TURTLE

4
5. Instrucons for placement and setup
Keep away from any direct source of smoke, dust, heat and water.
Install on a level surface that is stable and where there is no risk of the sensor being pushed over. Do not place it on
so materials and make sure the boom airow is never blocked.
Make sure the solar panel is well illuminated by sunlight during the day and faces the direcon of the sun. You can
nd guidance on the internet about which is the best direcon (depending on your geolocaon and me of the
year) to face any solar panel to get the maximum amount of sun hours covered during the day.
Clean the glass surface of the photovoltaic solar panel with a so damp cloth every month or if you noce any dirt
on it. Handle the panel with care and make sure to not leave any scratches.
Do not expose the sensor to risk and place it stable Do not put it directly on plants or the airow gets blocked
www.tea-group.it

5
Turtle overview and controls on boom side :
1) Control panel (see details on right) A) Power switch (ON-OFF)
2) Plug connector for power supply (oponal) B) 4 Status LEDs (see table below)
3) Temperature sensor C) Push-buon (to get Provisioning)
4) Air intake for AQ sensor D) Orientaon Legend
5) Air ouake
6) Oponal mounng arm sockets
7) Sensor label with idencaon serial
START
1. Switch the Power switch to ON. (make sure sensor is fully charged by sun or power supply)
2. Onboard Turtle and set up the WiFi connecon (Use provided link or QR code)
*To Provision the sensor press and hold the buon “P” and switch the Power switch to ON.
6. Instrucons for Installaon and starng
LED Status Table. Error codes and Flashing paerns explanaons
1. LED L1 is on when charging with the external power supply.
2. LED L2 + L3 + L4 will ash synchronously (2 ashes per sec), during the rst start-up, with the sensor not congured.
3. Aer conguraon LED L2 + L3 + L4 will ash synchronously (1 ash per second for a short me) during boot phase.
Then only LED L2 will ash (1 ash every 5 seconds) and the LED L3 & L4 will remain o.
4. Approximately every 15 minutes LED L3 will ash with LED L2 at L1 ash per second, indicang sensor data acquision.
5. Every 24 hours, LED L4 will ash with LED L2, about one ash per second , indicang GPS data acquision.
6. In some cases the acquision of GPS data may coincide with the acquision of sensor data, in this case we will see:
LED L2 + L3 + L4 ash synchronously at one ash per second.
7. In the fail condion, L2 will ash, about 5 ashes per second, the status of L3 or L4 is irrelevant to the signal.
www.tea-group.it
LED 2 LED 3 LED 4 ashing per second Time laps STATUS soluon
yes NO NO 5x per second innity FAIL condion Restart
yes yes yes 2x per second Unl APP “ON”In provisioning Wait...
yes yes yes 1x per second 15-30 sec In acquision Wait...
yes NO NO 1x per 5 seconds 15 min working /

6
7. Technical specicaons
Power Requirements: Solar panel included
Internal lead acid baery (Oponal: a backup charger with Input: 100/240V ~ 50/60Hz 0,85A
Output 6,0 V = 2,4A 14,4 W IP20
SENSORS Type Units Range#1 Resoluon#3 Accuracy#4
Parcles PM10#5 Opcal parcle counter µg/m3 0-1000 µg/m3 1.0 10%
Parcles PM2.5#5 Opcal parcle counter µg/m3 0-1000 µg/m3 1.0 10%
Air temperature Solid state °C -20 / + 70 0.3 5%
Air humidity Solid state % 0 – 100 1.0 5%
Enclosure Environmental Mounng Size & weight
ABS, protecon IP44 Temperature range: -20°C to +70°C
Humidity range: 0 to 100% RH Tested
Outdoor Mounng: Length: 210 mm
Height: 220mm
Weight: 3,4kg
Mount: 350mm x 120
mm x 0,4 Kg
Communicaons Measurement period Transmission frequency Server soware Data access
Raw data sent to re-
mote server via WiFi
Connecon
30 seconds 15 minutes Web browser based,
processing of sensor
output to give reading,
database storage on
secure server
Tables, graphs, data
download, mul-user
access, oponal API
data access
9. Guarantee
Turtle staons were tested in extreme environment and harsh condions and resulted to be a robust and reliable
outdoor sensor unit. The sensor requires periodical maintenance, periodical recalibraon and periodical cleaning
procedure is suggested.
Clean the glass surface of the photovoltaic solar panel with a so damp cloth every month or if you noce any dirt
on it. Handle the panel with care and make sure to not leave any scratches.
For calibraon procedures it is necessary to use a cered laboratory. Standard maintenance and cleaning proce-
dures can be operated by the users.
Never open or manipulate the device, it will render the guarantee void and is dangerous.
The Turtle sensor device is covered by legal guarantee as described in the European direcve (EU) 2019/771
DIRECTIVE (EU) 2019/771 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL
www.tea-group.it
8. Maintenance

7
MOUNTING TURTLE ON VERTICAL POLE
10. Oponal parts
External baery charger for Turtle Input: 100/240V ~ 50/60Hz 0,85A
Output 6,0 V = 2,4A 14,4 W IP20 ; Wire 3500 mm .
(To order: choose plug and relave code)
802066-1 Eur
802066-3 UK
802066-2 US
8 ØMOUNTING TURTLE ON THE WALL
1. DRILL HOLES WITH THE PACKAGING
CARDBOARD TEMPLATE
2. ASSEMBLE TURTLE ON METAL BRAKET
1. TIGHTEN METAL BRAKET TO VERTICAL POLE
2. ASSEMBLE TURTLE ON METAL BRAKET
ORIENTATION
HEX SCREW
MAX DIAMETER Ø55mm
801070 METAL MOUNT ARM WITH ACCESSORIES
TOOLS REQUIRED
use level
use level
www.tea-group.it
1. LOOSEN HEX SCREW
2. ORIENT TOWARDS THE
MAJOR SUNLIGHT SOURCE
3. TIGHTEN HEX SCREW
Oponal support mount and xture accessories
for on wall or on pole installaon instead of
regular stand-alone installaon on at surface.
Ø 5mm
Indice