Teba therm TP-05 Manuale utente

Installation and User Manual
Model
TP-05 / TP-06 / TP-07 / TP-08/ TP-09
TP-10 / TP-11
Pellet Stove
Tested according to DIN EN 14785
E
N

TABLE OF CONTENTS
1. INTRODUCTION..............................................................................................................................................................3
2. FEATURES.......................................................................................................................................................................3
3. WARNING ......................................................................................................................................................................3
4. INSTALLATION AND CONNECTION ................................................................................................................................4
4.1 GENERAL..................................................................................................................................................................4
4.2 SAFETY .....................................................................................................................................................................4
4.3 ELECTRICITY .............................................................................................................................................................5
4.4 FLUE PIPE CONNECTION ......................................................................................................................................5
4.5 MINIMUM SAFETY DISTANCES ..........................................................................................................................10
5. CONTROL PANEL..........................................................................................................................................................11
5.1. ERROR CODE AND EXPLANATION.........................................................................................................................12
5.2. MENU FUNCTIONS................................................................................................................................................13
5.2.1 COMBUSTION FUNCTIONS MENU..................................................................................................................13
Level;........................................................................................................................................................................13
Auger Calibration;....................................................................................................................................................13
Fan Calibration;........................................................................................................................................................13
5.2.2. HEATING MANAGEMENT ..................................................................................................................................13
5.2.4. CHRONO MENU.............................................................................................................................................14
5.2.5. LOADING MENU............................................................................................................................................15
5.2.6. TIME AND DATE MENU..................................................................................................................................15
5.2.7. LANGUAGE MENU .........................................................................................................................................15
5.2.8. ENTRANCE MENU ..........................................................................................................................................15
5.2.9. SYSTEM (PARAMETERS) MENU .....................................................................................................................15
6. CLEANING AND MAINTENANCE...................................................................................................................................16
6.1 FLAME PIPES CLEANING.........................................................................................................................................18
6.2. COMBUSTION POT CLEANING ..............................................................................................................................18
6.3 ASH TRAY 1 AND ASH TRAY 2 CLEANING...............................................................................................................19
7. GENERAL WARRANTY AND POLICIES...........................................................................................................................19

1. INTRODUCTION
Pellet stoves are easy-to-use domestic heating appliances. They are fully automatic and
can be used inside the house. These indoor heating units combines pleasure with a
fireplace view.
You have a stove with European Standards Quality Certificate.
Please read the user manual, carefully.
It includes information on product functions and easy-to-use information.
Use of these informations increases the product quality and extend its life. You can
properly protect the fuel and the environment.
Warranty of the product depends on the right use of installation and instructions as
described in the guide.
We recommend you to keep this guide in order to reach the information about the correct
use of the stove at the beginning of every winter.
2. FEATURES
TECHNICAL
FEATURES
TP-05
TP-06
TP-07
TP-08
TP-09
TP-10
TP-11
Power (kW)
8
9
9,8
10
10
10
18
Flue pipe
diameter
80 mm
80 mm
80 mm
80 mm
80 mm
80 mm
80 mm
Pellet
storage
capacity
15 KG
15 KG
15 KG
15 KG
10 KG
20 KG
20 KG
Efficiency
89,4 %
88,1 %
88,1 %
92 %
90 %
89,5 %
93 %
Electric
230 V-
50Hz
230 V-
50Hz
230 V-
50Hz
230 V-
50Hz
230 V-
50Hz
230V-
50Hz
230 V-
50Hz
Weight
73 kg
75 kg
78 kg
128 kg
101 kg
148 kg
207 kg
3. WARNING
●USE ONLY 6MM NATURAL PELLETS MANUFACTURED ACCORDING TO DIN PLUS
STANDARTS.
●DO NOT USE 8MM OR 10 MM PELET, OLIVE SEEDS, CHERRY SEEDS, HAZELNUT
SHELL ETC.

●CLEAN THE FIRE POT EVERYDAY.
●AT THE END OF THE WINTER, GENERAL MAINTENANCE AND CLEANING MUST BE
CARIED OUT AND THE FUEL STORAGE MUST BE EMPTIED.
●DAMAGES CAUSED BY USING INAPPROPRIATE PELLET AND NON-REGULAR
CLEANING ARE NOT COVERED BY WARRANTY.
●SMOKE AND SMELL IS NORMAL AT FIRST USING. JUST VENTILATE THE ROOM.
●DO NOT TOUCH PAINTED PARTS DURING OPERATION TO AVOID DAMAGING ON
PAINT.
●THE PROBLEMS CAN BE OCCURED IN CASE WRONG/LOW QUALITY PELLET
USING AND CLEANING IS NOT MADE, ARE NOT COVERED BY THE WARRANTY.
4. INSTALLATION AND CONNECTION
4.1 GENERAL
All the inspections for the pellet stove are done according to the stipulated standards. It
complies with the prescribed parameters related to combustion efficiency and flue gas
emissions. The product mentioned in this manual has been tested by the approved bodies
according to EN 14785 Standard.
The packaging of the stove protects the product from damage in the best possible way.
However, the stove or its accessories may still be damaged during transport. Therefore,
after removing the stove from the package, check whether it is complete and undamaged.
In case of any damage, notify your dealer. If dealer or manufacturer are not informed
about the damage and not presented the proof, the damages are not covered by the
warranty.
4.2 SAFETY
* Product must be installed by an authorized person.
* Before installing the product, it should be determined whether the bearing capacity of
the floor to be installed is durable to the product. In case of insufficient bearing capacity,
appropriate measures should be taken. If the floor where the stove is to be installed is
flammable or heat-sensitive, you should place a base (eg marble or glass base).
* Care must be taken to ensure that the ventilation conditions of the place where the
product is installed.
* The pellet stove can operate in conjunction with the existing multiple chimneys. In
addition, the stove should not be connected at places such as the aspirator chimney and
ventilator.
* Chimney must be cleaned at least twice a year.
* Product needs to be connected to the chimney with a shortest distance.

* In order to get better heat efficiency and extend the life of the product, qualitative pellet
and wood fuel should be preferred. Do not use moist or wetted pellet, sawdust, coal etc.
* Since the pellet stoves are designed according to the interior spaces and give heat to the
environment, they should not be installed in places such as bathrooms, shelter, cellar.
And they should not be used for cooking.
4.3 ELECTRICITY
The electricity must be 230V / 50 Hz 10A.
Our company is not responsible for any damage that may occur in case of any voltage
drop or rise. We recommend taking necessary measures as it does not include the
warranty.
4.4 FLUE PIPE CONNECTION

We recommend the use of twin(double) wall or twin(double) wall insulated system for
chimney connection.
•In the interior spaces, by using twin wall chimney system, exhaust gas can be throughed
out to the outside, at the same time fresh air provided to inside. Twin insulated chimney
should be used on the outside.
•In the interior spaces, by using twin wall insulated chimney system, exhaust gas can be
throughed out to the outside. In this case, you can provıde fresh air by additional pipe
and elbow.
•To provide fresh air easily, a vent should be used on the nearest window where stove is
installed.
•Chimney or twin wall insulated chimney, should be at least 80 cm higher than the highest
point of the roof.
•Use rain cap or wind cowl at the end of the chimney to avoid to come inside
anything(bird,etc…). Distance between raincap and chimney end should be 30-40 cm.
•The pellet stove can operate in conjunction with the existing multiple chimneys. In
addition, the stove should not be connected at places such as the aspirator chimney
and ventilator.
•The chimney can be given directly out of the pellet stove at a short distance, or it
can be connected to the existing chimney at short distance.
ATTENTION !!!
THE PIPE AND ELBOWS USED UP TO THE CHIMNEY OUTPUT AND INPUT NEEDS TO BE THE SAME
DIAMETER. BY THE INPUT OF THE CHIMNEY A REDUCTION MUST BE USED. MAXIMUM 4 METERS
PIPES AND 2 ELBOWS NEEDS TO BE USED. PIPE JOINTS SHOULD BE TAPED TO CONNECTOR OR
ALUMINUM BAND.

ROOM THERMOSTAT
CONNECTION POINT
TP-05 / TP-06 / TP-07

TP-08
TP-09

TP-10
TP-11

4.5 MINIMUM SAFETY DISTANCES
A50 cm from rear wall
B40 cm from lateral wall
C100cm from front side
Flammable materials and
furniture should not be
placed at a distance of 100
cm in the radiation area
(C) of the flame
monitoring cover.
While installing the stove, the fire regulations and chimney’s instructions must be complied.
For any related questions please ask the chimney provider. Minimum distances to be
observed in flammable or heat-sensitive materials (eg furniture, wallpaper, wood panels)
(see diagram above) are:
This distance can be reduced to 40 cm when the protection panel is placed between the
stove and the materials that are likely to burn.
Minimum distances for flammable materials and furniture are indicated on the product
label and must not be exceeded. If the floor where the stove is to be installed is flammable
or heat-sensitive, you should place the product on the ground protection plate (eg marble
or glass base).
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali Teba therm Stufa