Tecnoalarm TP8-96 Guida utente

TP8-96 VIDEO
864 ZONES
CONTROL PANEL
8 TO 96 ZONES EXPANDIBLE
CONTROL PANEL
WITH INTEGRATED
ETHERNET SWITCH
EN60950
EN50130-4
EN50081-1
INSTALLER
MANUAL
Release: 1.0
Update: July2011
Language: English
FWversion: 0.7.05

II InstallerManual-TP8-96VIDEO
Theproductfeaturescanbesubjecttochangewithoutnotice.Unauthorizedreproductionordistributionofthis
manual, or any portion of it, on any device and in any form, is prohibited. The contents of this manual may be
subject to change without notice

III
TP8-96VIDEO-InstallerManual
CONFORMITY
Hereby,Tecnoalarm srl declaresthat the presentequipment is incompliance with theessential requirements and
otherrelevantprovisionsoftheR&TTE1999/05/ECdirective.
Thedeclarationofconformityisavailableonthewebsite:www.tecnoalarm.com.

IV InstallerManual-TP8-96VIDEO

TP8-96VIDEO-InstallerManual Index 1
INDEX
1. INTRODUCTION TO THE TP8-96 VIDEO SYSTEM
1.1 PROGRAMMINGMENU 1-1
1.2 HARDWARECONFIGURATION-AVAILABLEMODULES 1-7
2. PROGRAMMING OF ZONES AND PROGRAMS
2.1 ZONECONFIGURATION 2-1
2.1.1 Creationoflistandparameters 2-1
2.1.2 Zone-functionassociation 2-11
2.1.3 Zone-programassociation 2-13
2.1.4 Consoles 2-14
2.1.5 Keypoints 2-16
2.1.6 Options 2-17
2.1.7 Outputs 2-20
2.1.8 Bus sirens 2-22
3. PROGRAMMING OF TELEPHONE SECTION
3.1 TELEPHONEPARAMETERCONFIGURATION 3-1
3.1.1 Telephonechannelsandstandardtelephoneparameters 3-1
3.1.2 GSMmodule 3-4
3.1.3 Tecnocell 3-6
3.1.4 Ethernet 3-8
3.1.5 Teportcodes 3-10
3.1.6 Openingmessage-vocabulary 3-11
3.1.7 Remotecontrols 3-13
3.2 EXPLANATORYNOTES 3-14
3.2.1 Telephonenumbers 3-14
3.2.2 Protocols 3-15
3.2.3 Communicatorblock 3-17
3.2.4 Airtimerequest 3-17
3.2.5 Call-back 3-18
3.2.6 Ethernet 3-20
3.2.7 Remotecontrolmanagement by SMS 3-21
4. PROGRAMMING OF TIME PARAMETERS
4.1 TIMESETTINGS 4-1
4.2 TIMERS 4-3
4.3 ACCESSPERIODS 4-5
4.4 CUSTOMIZATIONOFTHECALENDAR 4-7
4.5 EXPLANATORYNOTES 4-9
5. POGRAMMING OF ACCESS CODES AND KEYS
5.1 PROGRAMMINGOFTHECODES 5-1
5.2 PROGRAMMINGOFTHEKEYS 5-4
5.3 PROGRAMMINGOFTHEWIRELESSKEYS 5-6
5.4 EXPLANATORYNOTES 5-8
6. PROGRAMMINNG OF WIRELESS DEVICES
6.1 PROGRAMMINGOFTHEWIRELESSSIRENS 6-1
6.2 PROGRAMMINGOFTHEWIRELESSCONSOLES 6-3

Index InstallerManual-TP8-96VIDEO
2
7. HARDWARE CONFIGURATION
7.1 ADDITIONORDELETIONOFMODULES 7-1
8. RS485 SERIAL BUS ANALYSIS
8.1 SERIALBUSANALYSIS 8-1
A. APPENDIX A - APPENDIX SPECIAL PROCEDURES
A.1 RESETOFTHEDEFAULTCODES A-3
A.2 COMPLETEDELETIONOFSYSTEMCONFIGURATION(RESETOFDEFAULTSETTINGS) A-4
A.3 BACKUP/RESTOREOFTHECONFIGURATIONOFTHEWIRELESSSECTION A-5
A.4 FIRMWAREUPGRADE A-7
Electronicboard A-11
Terminals A-12
System A-13
Cameraconnection A-14
Supply by terminals A-15
Supply by cables + splitter A-16

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-1
1.1 PROGRAMMING MENU
Descriptionoftheprogrammingmenus.
zAdvanced:Enablingordisablingofadvancedprogramminglevel.
N.B.It is possible to enable the advanced programming level only if you are in
possession ofthe corresponding license.
zAutomatic wiring:Enabling or disabling of the automatic wiring function.
N.B. All the other items of the option window are disabled.
zZones: Association of the logical zones to the physical zones, alphanumerical
description, enabling of voice message, zone type, alarm cycles, alarm counter,
contact type, configuration of the connected detector, enter filter and sensitivity
zZones-functions:Association of the followingfunctions to the zones:siren, PGM, by-
pass, coinciding zone, chime, non excludable zone, common zone
zZones-programs:Associationofthezonestotheprograms,alphanumerical
descriptionof theprograms, enabling of the voicemessage
zConsoles:Consoleconfiguration,association of the program statusLEDtothe
programs, quick arming/disarming, panic alarm, quick menu, chime, audio settings,
messagescheduling
zKeypoints:Associationoftheprograms
zOptions: Buzzer section, wireless section, voice report, key zone properties, single
armingmode,enabling/disablingtamper,antimasking control, association of the
siren and PGM outputs to the programs
zOutputs:Outputconfiguration,polarityprogramming
zBus sirens:Associationofthesirenstotheprograms,aftersoundblinking,volume
setting,siren mode, soundtype,functioningmode,enabling/disabling of theantifoam
andantidrillingprotection
PROGRAMMINGOPTIONS
ZONECONFIGURATION
1. INTRODUCTION
PROGRAMMINGOPTIONS

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-2
TELEPHONE SECTIONCONFIGURATION
zTelephone interface:Programming of the channels from A to H, call back function,
commmunicatorblock,generalsettings
zGSM: Enabling of the GSM interface, answering mode, rings, airtime request, SMS
heading, GPRS settings, commands by SMS, password, white list
zTecnocell:Enablingofthe external GSM communicator, answering mode,emergency
phonenumber,associationofthe messages, emergency SMS, enabling oftheguided
menuandof the data channel
zEthernet:Configurationoftheintegrated 8 ports Ethernet switch,IPaddress, subnet
mask,gateway,programmingofthecommunicationportfortheLocalServer
Tecnoalarm,RemoteServerTecnoalarm,TecnoserverTecnoalarm,Tecno_Out
zReport codes:Programming ofthereportcodesofall8channelsfortheevent
transmission
zOpening message - Vocabulary:Test/recording/loading of the opening message,
loadingandupdateofthevocabulary
zRemotecontrol: Remotecontrolmessage, alphanumericaldescription,
programmingoftheactivationtime
zTime settings: Entry time 1 and 2, exit time, disarming confirmation time, delay of
channelandsirenactivation,antimaskingandpower failure,alarmtime,tamper,
technicalandhold-upalarmtime; duration of end of by-passandautomaticarming
warning,maximumdurationofby-pass,supervisioninterval
zTimers:Frequency and moment of activation, association of the function
zAccessperiods:Frequencyand moment ofactivation,associationoftheaccess
periodstothecodes,transponders/RFIDandremotecontrols
zCustomization 1st year:Programmingofthe working days, holidays andholiday
eves,winterandsummertime,viewingofthescheduledmessageontheconsole
zCustomization 2nd year: Same as for the first year
TIMEPARAMETERCONFIGURATION

TP8-96VIDEO-Installermanual IntroductiontotheTP8-96VIDEOsystem 1-3
ACCESSCONFIGURATION
zCodes:Programming ofthecodes,nameand lengthofthecode, arming/disarming
function and by-pass, association to the programs, attributes
zTransponders: Programmingofthetransponders,name, arming/disarmingfunction
and by-pass, association to the programs, attributes
zWireless keys: Programming of the wireless keys, name, association of the keys to
theprogramsor the functions, attributes
zWireless sirens:Alarmtime, siren delay, flashing time, volume setting,functioning
mode
zWireless consoles: Association of the program status LED to the programs, attributes
zEvents ->Operations:Whenaspecific event happens, the controlpanelexecutes a
specific operation associated to the event, e.g.:
• What kind of event? Arming
•Whicharming?Remotearming
• By whom? User 1
•Whichprogram?Program2
•How? By telephone
zOperations:Creationofanewoperation,operationmodification,operationdeleted
zTelephone directory: Association of specific telephone numbers to the operations
WIRELESSDEVICECONFIGURATION
ADVANCEDPROGRAMMING

IntroductiontotheTP8-96 VIDEO system Installermanual-TP8-96VIDEO
1-4
EVENTLOG
Viewing,printingandsavingasatextfile(TXT)ofthecontrolpaneleventlog.Thestoredeventsareviewedwith
indication of date and time. You can list the event log by date or type.
zN.:Event number. Click to list in chronological order (recordingsequence)
zDate and time: Click to view the events of a determined period of time
zDescription: Event description. Click to list the events by type and view the events of a
specific type
Hardwareconfigurationofthesystem.
Thismenu permits addition or deletion of thehardware modules ofthe system.
zAdd: Click on "add" to add the device selected in the list.
zDelete: Click on "delete" to delete the device selected in the list.
zModules available: List of the modules available for the system.
HARDWARECONFIGURATION
FLOORPLANCONFIGURATION
This menu allows to create and to manage the floor plans associated to the system.
Thismenuisonly enabled if you have thecorrespondingTecnoalarmlicenseand the automatic wiring option is
disabled.
zMenu which permits the selection of the useful elements to create the floor plan.
Forviewingspecificcommandsareavailable.
zSymbols available:For floor plan configuration
Altri manuali per TP8-96
2
Indice
Altri manuali Tecnoalarm Pannello di controllo